My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1996-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
CORRESPONDENCE_1996-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 10:06:31 AM
Creation date
12/28/2021 11:49:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1996-2002
RECORD_ID
PR0440004
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
Active, billable
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
6484 N WAVERLY RD LINDEN 95236
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 � F <br /> Monitoring Report Compliance Chist <br /> Discharges Regulated by Title 27 and/or Part 258 <br /> RWQCB <br /> Reference Parameter Yes No N/A Reviewer Comment <br /> WDRs/MRP/ Groundwater Monitoring <br /> Standard <br /> Provisions 1. Are all groundwater Field Parameters X <br /> (Sept 93/Aug 97) Monitoring Parameter,and COCs <br /> (if required) samples and analyzed? <br /> m. Have any groundwater concentration X Chlorobenzene detected in MW- <br /> limits been exceeded? If yes,identify 1 at 2.6 and in MW-2 at 2.7 µg/1. <br /> in comments. <br /> n. Is there a description and graphical X <br /> presentation of groundwater flow <br /> direction and gradient? <br /> o. Monitoring Wells: Is there a X Recorded the recoveries for first <br /> description,method,and time 5 minutes after purge. <br /> of water level measurement and <br /> well recovery time? <br /> p. Purging: Is there a description X Dedicated purge and sample <br /> of the purging method,purge pumps. <br /> pump and its placement, and <br /> field parameters? <br /> Additional Comments and Recommendations: <br /> Monitoring well MW-1 is the upgradient well. Flow direction is toward MW-2. Wells are being resampled <br /> and retested. County feels that the detects may be due to lab error. <br /> Purge rate is approximately 0.5 gallon per minute for each well. <br /> RWQCB Staff Signature: G�• <br /> Date: <br />
The URL can be used to link to this page
Your browser does not support the video tag.