Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RYDER TRUCK RENTAL#1071 3633 DUCK CREEK DR, STOCKTON January 27, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 308 CCR 2632(c), 2634(d), 2636(f) Failure of the leak detection equipment to have an audible and visual alarm. <br /> OBSERVATION: The 208 sensor located in the UDC for dispenser 1 failed to activate an audible and visual alarm <br /> when tested to ensure continuous monitoring of the tank system. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: The sensor was replaced and retested during the inspection. <br /> This is a repeat violation, Class II. <br /> 318 CCR 2635, 2637.1,2665, 2712 Failed to meet spill container requirements. <br /> OBSERVATION: The 6000 gallon diesel, used oil and new oil spill containers failed when tested. <br /> REGULATION GUIDANCE:All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to repair or <br /> replace the spill container under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 27, 2022. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> Documents provided during inspection: Return to Compliance certification, flyer for free CUPA classes, UST <br /> Training Certificate form. <br /> NOTE: Testing for the leak detector on the 12,000 gallon diesel tank(99LD2000)was not completed during the <br /> inspection. The monitoring system certification must be conducted by a properly licensed and certified tester by <br /> the end of the month. All EHD staff time associated with a re-inspection will be billed at the current hourly rate <br /> ($152). Please email ust@sjgov.org at least 48 hours in advance when testing of the leak detector will be <br /> conducted. <br /> FA0003758 PR0232461 SCO01 01/27/2022 <br /> EHD 23-01 Rev.12/06/2021 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />