Laserfiche WebLink
z <br /> J KEYNOTES <br /> a- <br /> fl� 1O EXISTING RECTANGULAR SUPPLY AIR DUCT DOWN THROUGH ROOF TO <br /> 0 BELOW FLOOR SLAB WITH TURNING VANES. TYPICAL. pw <br /> :31 <br /> I O2 EXISTING RECTANGULAR RETURN AIR DUCTWORK ROUTED ABOVE CEILING <br /> Q AND RISE UP THROUGH ROOF. TYPICAL. <br /> U ARCHITECT PBK-WLC,Inc. <br /> O3 EXISTING BELOW SLAB SUPPLY AIR DUCT SYSTEM TO REMAIN. EXISTING <br /> Q DUCTWORK HAS BEEN INVESTIGATED, CLEANED AND CERTIFIED FOR REUSE PBK-WLC.com <br /> WITH INTERIOR DUCT SEALANT APPLIED. TYPICAL. SACRAMENTO <br /> U 2520 Venture Oaks Way,Suite 440 <br /> W ® REMOVE FLOOR SUPPLY DUCT SEALS AND PROVIDE GRILLE AS SPECIFIED AT Sacramento,CA 95833 <br /> ALL FLOOR OUTLETS. GRILLE NECK SIZE TO MATCH EXISTING PLENUM 916-682-9494 P <br /> C) DIMENSIONS. TYPICAL. PROVIDE GALVANIZED SHEET METAL AT SUPPLY <br /> N PLENUMS AT THE NORTH AND NORTHWEST FLOOR OUTLET IN MP WEST Electrical Engineering <br /> 2 ROOM 116 AND EAST FLOOR OUTLETS IN MP EAST ROOM 111. <br /> 0 REMOVE WALL RETURN DUCT SEALS AND PROVIDE GRILLE AS SPECIFIED AT ) LEAF <br /> ALL WALL INLETS. CLEAN AND VACUUM RETURN AIR DUCTWORK PRIOR TO <br /> INSTALLATION OF NEW GRILLES AT THIS LOCATION. TYPICAL. E N G i NEER s <br /> ♦Pte(COMPANY <br /> 2520 Venture Oaks Way,Suite 440.Sacramento,CA 95833 <br /> © PROVIDE NEW THERMOSTAT TO LOCATION AS SHOWN AND AT MOUNTING p916-682-9494 www.LEAFengineers.com <br /> HEIGHT TO MEET ALL CODE REQUIREMENTS. EXTEND EXISTING CONTROL job#:P2102201AR <br /> WIRING BEHIND FINISHED SURFACES TO NEW THERMOSTAT LOCATION. <br /> TYPICAL. PATCH TO MATCH EXISTING CONDITIONS. TYPICAL. <br /> O7 PROVIDE NEW EXHAUST DUCTWORK FROM EXHAUST FAN ABOVE CEILING TO <br /> NEW ROOF PENETRATION LOCATION. COORDINATE ROUTING WITH ALL <br /> EXISTING AND NEW CONDITIONS. EXISTING CAPPED EXHAUST DUCT RISER <br /> THROUGH ROOF TO REMAIN. TYPICAL. <br /> ® PROVIDE NEW LINED TRANSFER AIR DUCT ROUTED ABOVE CEILING FROM <br /> SERVERY TO CORRIDOR. FIELD VERIFY ROUTING OF NEW DUCTWORK WITH <br /> ALL EXISTING AND NEW CONDITIONS INCLUDING STRUCTURAL ELEMENTS, <br /> CEILING SUPPORTS AND LIGHT FIXTURES. <br /> O9 PROVIDE NEW CEILING AND WALL SUPPLY AIR DIFFUSERS FOR AIR <br /> DISTRIBUTION SYSTEM SERVING EXISTING AC-5 UNIT. COORDINATE EXISTING <br /> DIFFUSER NECK SIZE WITH SPECIFIED PRODUCT. VACUUM EXISTING <br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DUCTWORK WHERE DIFFUSER HAS BEEN REMOVED. EXISTING <br /> KEY-OPERATED VOLUME DAMPER AT ALL DIFFUSERS SHALL BE VERIFIED AND <br /> CHECKED FOR OPERATION. RE-BALANCE TO CFM AIRFLOW INDICATED. <br /> NOTIFY ENGINEER OF ANY DISCREPANCIES. TYPICAL. <br /> 10 PROVIDE NEW CEILING RETURN AIR REGISTERS FOR AIR DISTRIBUTION <br /> SYSTEM SERVING EXISTING AC-5 UNIT. COORDINATE EXISTING REGISTER <br /> NECK SIZE WITH SPECIFIED PRODUCT. VACUUM EXISTING DUCTWORK WHERE <br /> REGISTER HAS BEEN REMOVED. EXISTING KEY-OPERATED VOLUME DAMPER <br /> AT ALL REGISTERS SHALL BE VERIFIED AND CHECKED FOR OPERATION. <br /> RE-BALANCE TO CFM AIRFLOW INDICATED. NOTIFY ENGINEER OF ANY <br /> DISCREPANCIES. <br /> 11 PROVIDE TRANSFER LINED TRANSFER AIR DUCT, SIZE AS INDICATED. z <br /> COORDINATE ROUTING WITH ALL EXISTING AND NEW CONDITIONS. N <br /> O <br /> LL. <br /> J <br /> - Q <br /> U <br /> A 24x6 <br /> CONFERENCE A 24x6 PRINCIPALS <br /> 560 CFM ROOM 560 CFM OFFICE STORAGE N <br /> 110 I I 111 <br /> 130 wL.L <br /> II II = <br /> 101 ISI g H <br /> PRIVATE OFFICE PRIVATE OFFICE 1 o I elf <br /> I"' I IwI N O <br /> 101 102 <br /> 024x6 015x15 1"I 015x15 LU z <br /> C _ A 560 CFM RECEPTION F 560 CFM L J F 560 CFM <br /> 1 1 71 0 24x6 (n <br /> 100 � 560 CFM - Q J <br /> —„ 12x12 12x12 � ____ <br /> ---- (E) 12 Q1------- I 0125 CFM C 125 CFM I ( --- (E) 12"0 <br /> 1 r J ------------ <br /> 12x12 <br /> --------- O <br /> I I x <br /> o �X 11 I I x U Z <br /> x Z <br /> 01251CFM 9 _ EAC-5 T x 10 � i oo <br /> O cn 0 <br /> w 11 w <br /> 10 9 03 04 w 12x12 15x15 I 1 <br /> E( )AC-2 6 30x4 M6.01 M6.01 E 125 CFM 0560 CFM I 1 <br /> 0 300 CFM <br /> w I 5 18x18 T �� I w I J U w 0 0 <br /> D I I T I I 0 m 0 Z)27 C14 o <br /> 2t7 <br /> V I I O 30x10 �� 400 CFM LACTATION I I F 15x15 Q zO <br /> F600 CFM + it 18"x10" I 1 O 560 CFM Q U <br /> �� E[ - <br /> 560 <br /> 108 x (� z U <br /> A 24x6 2 1 TOILET p CFM r—� - 024x6 J <br /> r 00 <br /> 104 12x12 w (E)20"x14" UP L A 560 CFM Y ~ <br /> (E)20"x14" UP 0100 CFM r— �_ �_ O U <br /> Q <br /> ---- —� <br /> (E) 12'�Q1----- ) I 12x12 0 � STORAGE x C 1251CFM I -------E 12"f- ———-- � � � � O � <br /> iv (E) r` cn U <br /> -------------� 0125 CFM ABLESTORAG - x w 7 1 ( ------------- <br /> I 103 _ r <br /> °0 22x46 <br /> 1 O B 30x10 123 N Lu 18"x10" 01680 CFMI <br /> 600 CFM w ® a[ 100 <br /> 4 I w i E 12x12 (E)10"x6" 1 w <br /> E I O 125 CFM 8"� L I KI PP.Public Schools <br /> 1177— (I - 12x12 I E <br /> 12x12 _ ( 10"x6" ----QE 125 CFM <br /> O125CFM E 12x12 —� NORTHERN CALIFORNIA <br /> rr--------------- -------- -5x0 N w — — --- ---125 CFM -------_ <br /> 1 (E) 18"0 iX : STORAGE �� <br /> —L-------- ---- ------ w JANINTOR (E) 18"O 1 \ / <br /> F 106 107 — ---- ---------------J—� F <br /> (E)25"x12" DN (E)25"x12" - <br /> 3 (E)20"x12" � DN ADMINISTRATIVE <br /> (E)20"x8" 11 DL EF 09 OPEN OFFICE <br /> 1 <br /> STORAGE i 1 M6.01 109 STORAGE <br /> 122 10"x7' (E) 18"x8" (E)20"x14" ;� Fi <br /> Al <br /> FF <br /> _ x <br /> G (E) 10"x7" iv <br /> HALLWAY <br /> 12x12 <br /> c:) 12x12 w <br /> 0150 CFM 105 C 150 CFM <br /> 00 <br /> (E)25"x12" DN (E)25"x12" EF 09 <br /> H DN '� 2 M6.01 H 1 P2 P3 P4 P5 P6 <br /> w <br /> ---------------- -------- -- --- ---------------i—� <br /> / \ 1 (E) 18"0 (E) 18"0 N <br /> L-------------- -------- - - ---- --------------- <br /> — 12x12 E 10"x6„ (E) 10"x7" (E) 10"x6" E 12x12 — <br /> 0125 CFM ( ) 125 CFM 1 <br /> PLAN TRUE <br /> � I COPY ROOM .10 <br /> KEY PLAN NORTH NORTH <br /> 12x12 E 10"x6" 12x12 1 <br /> 024x6 I 0125 CFM (E) 10"x6" 115 8x12 ( ) E 125 CFM 1 <br /> 560 CFM I I TABLE STORAGE <br /> 1 w l B 30x10 0150 CFM B 30x10 1 w I 0560 CFM <br /> ---- -----� I O600CFM 120 ® 6"0 O600CFM 1 ------------- <br /> (E) 12"QJ ) I (E) 8"x7" (E) 12"x8" (E)20"x14" UP 1 ( (E) 12"0 <br /> --------------r I (E)20"x14" UP E 8x6 12x12 1 �------------- oQROFESS/pNgl <br /> r 1 12x12 <br /> 16"x8" L 00 C 125 CFM r—1 ���, ``�M.LEN�i < <br /> 0125 CFM x TABLE STORAGE u�j ��� <br /> 14x14 O 30x10 I w m <br /> B 30x10 O 300 CFM g w 1 114 600 CFM r 0. 333 0rn <br /> 0600 CFM \ I 1 <br /> REN.6-3 2 <br /> J <br /> ISIT I I <br /> I EAC-1 O _T 02 03 04 �� I � 1 spy HAN <br /> F OF CAS\F� <br /> M6.01 M6.01 M6.01 1 <br /> I <br /> IT I `" I <br /> 119 0- E 16x1624x6 1_41 03 04I 1 24x6 <br /> 0560 CFM I I EF 09 1 EF-3 0300 CFM 16x16 M601 M601 I 1 0560 CFM <br /> 2 M6.01 C I 1 CLIENT <br /> 300 CFM _______ ____ KIPP:PUBLIC SCHOOLS NORTHERN CALIFORNIA <br /> ----(E) 12"0 ------�) I 01 I (�------ (E) 12"0 ---- PROJECT NUMBER <br /> PANTRY <br /> _L�] P2102201 AR <br /> U _ M6.01 SERVERY � <br /> W 03 04 118 DATE: <br /> 07/01/2021 <br /> M6.01 M6.01 116 DRAWN BY: KF CHECKED BY: RT <br /> ISI 1p I REVISIONS <br /> IwI IwI L # DESCRIPTION DATE <br /> Q MULTIPURPOSE I -I 1"I <br /> U WEST I I WATER HEATER FUTURE 1 I STORAGE <br /> 2 � �� CLASSROOM <br /> m 121 ,rte, 24x6 117 24x6 131 <br /> u O 560 CFM 113 1 O 560 CFM <br /> 00 <br /> °° LIA <br /> > CONSTRUCTION DOCUMENTS <br /> 0 <br /> Q <br /> N MECHANICAL <br /> N <br /> O <br /> N FLOOR PLAN <br /> a <br /> N � <br /> U <br /> Q C7 N <br /> Cn <br /> U � <br /> � N <br /> O <br /> N '� MECHANICAL FLOOR PLAN <br /> � o <br /> N co SCALE: 1/4" = 1'-0" <br />