My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DALLAS
>
742
>
1600 - Food Program
>
PR0547287
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 4:43:40 PM
Creation date
1/11/2022 10:39:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547287
PE
1632
FACILITY_ID
FA0026857
FACILITY_NAME
KIPP STOCKTON MIDDLE SCHOOL
STREET_NUMBER
742
STREET_NAME
DALLAS
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
742 DALLAS AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br /> J <br /> KEYNOTES <br /> 0_ <br /> 0 0 EXISTING PACKAGED AC UNIT TO REMAIN. PROVIDE AIR-BALANCE REPORT PRIOR pw <br /> 0 TO CONSTRUCTION. IN ADDITION TO AIRFLOW READINGS, REPORT SHALL INCLUDE <br /> CONDITION OF UNIT INCLUDING CONTROLS, FANS, COOLING COIL, COMPRESSOR, <br /> J HEAT EXCHANGER, DAMPERS, FILTERS AND OVERALL CONDITION OF UNIT. <br /> Q <br /> C COMPONENTS SHALL BE INDIVIDUALLY FIELD TESTED FOR UNIT OPERATION. <br /> z TYPICAL FOR EXISTING AC-1, AC-2, AC-3, AC-4 AND AC-5. ARCHITECT PBK-WLC,Inc. <br /> Q PBK-WLC.com <br /> r O2 EXISTING OUTSIDE AIR INTAKE HOOD AND 2 POSITION DAMPER TO REMAIN. SACRAMENTO <br /> C RECALIBRATE AND ADJUST DAMPERS TO ACCOMMODATE NEW OUTSIDE AIRFLOW 2520 Venture Oaks Way,Suite 440 <br /> W <br /> LU SETTING REQUIREMENTS. TYPICAL FOR EXISTING AC-1, AC-2, AC-3, AC-4 AND AC-5. Sacramento,CA 95833 <br /> C) 0 EXISTING RETURN AIR DUCTWORK SYSTEM SHALL BE LEAK TESTED WITH 916-682-9494 P <br /> cM CERTIFIED REPORT IDENTIFYING CONDITION OF DUCTWORK AND REPAIR TO BE Electrical Engineering <br /> CONSIDERED. ALL EXPOSED DUCTWORK ON ROOF SHALL HAVE JOINTS <br /> RESEALED. DENTS ON UPPER SURFACE OF DUCTWORK SHALL BE REMOVED AND <br /> NEW CROSS-BREAKING TO ALLOW WATER DRAINAGE. TYPICAL FOR EXISTING NLEAF <br /> AC-1, AC-2, AC-3, AC-4 AND AC-5. <br /> ENGINEERS <br /> A PBK COMPANY <br /> 2520 Venture Oaks Way,Suite 440.Sacramento,CA 95833 <br /> ® EXISTING SUPPLY AIR DUCTWORK SYSTEM SHALL BE LEAK TESTED WITH p916-682-9494 www.LEAFengineers.com <br /> CERTIFIED REPORT IDENTIFYING CONDITION OF DUCTWORK AND REPAIR TO BE job#:P2102201AR <br /> CONSIDERED. ALL EXPOSED DUCTWORK ON ROOF SHALL HAVE JOINTS <br /> RESEALED. DENTS ON UPPER SURFACE OF DUCTWORK SHALL BE REMOVED AND <br /> NEW CROSS-BREAKING TO ALLOW WATER DRAINAGE. TYPICAL FOR EXISTING <br /> AC-3 AND AC-4. <br /> O5 REMOVE EXISTING UTILITY EXHAUST FAN AND DUCTWORK. EXISTING ROOF <br /> CURBS TO REMAIN. PROVIDE NEW SHEET METAL CAPS SIZED TO SECURE TO <br /> EXISTING CURBS. CAPS SHALL BE WEATHER-TIGHT. TYPICAL AT ROOF <br /> PENETRATION AND UNIT PLATFORM. <br /> 0 ABANDON IN PLACE TOILET ROOM EXHAUST VENT ON ROOF. SEAL EXHAUST DUCT <br /> AT UNDERSIDE OF ROOF DECK. <br /> O7 PROVIDE NEW ROOF VENT. MAINTAIN A MINIMUM OF 10'-0" CLEARANCE TO ALL <br /> HVAC EQUIPMENT AND BUILDING OUTSIDE AIR INTAKES. TYPICAL. <br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 <br /> ® ROOF ACCESS HATCH. REFER TO ARCHITECTURAL PLANS. <br /> �Z <br /> LL <br /> O <br /> U_ <br /> J <br /> U <br /> Z <br /> LLJ <br /> 2 <br /> elf <br /> N 0 <br /> W Z <br /> Q J <br /> = 0 <br /> O <br /> O C/) Z I- <br /> � O z <br /> V U <br /> LU CD C <br /> K � 0 Z <br /> 0 <br /> 08 > z <br /> Q 0 <br /> M6.01 W co z j <br /> 0 <br /> E( )AC-3 ; 0 (J z <br /> % ( )20"x14" RA UP N OU <br /> (E)20"x14" RA UP <br /> 6 <br /> NN <br /> X 4 X KI PP:Public Schools <br /> 8 LO <br /> � N <br /> w w NORTHERN CALIFORNIA <br /> F. I (E)AC-2 <br /> (E)25"x12" SA DN.� <br /> 4D!(E)20"x16" RA UPAl <br /> (E)AC-4 <br /> F� (E)AC 1 <br /> (E)AC-5 � 1 P2 P3 P4 P5 P6 <br /> 2 V V N <br /> �/J A <br /> (E)25"x12" SA DN. <br /> PLAN TRUE <br /> - KEY PLAN NORTH NORTH <br /> O <br /> N � <br /> X - <br /> � N <br /> w 3 1 w <br /> `;2N,\ O QROFESS/O/V. <br /> (E)20"x14" RA UP,---- 08 "x14" RA UP ����`'���M'LENC�o�F�G1 <br /> M6.01 m <br /> NO. 333 0ni <br /> � � * <br /> REN.6-3 2 <br /> J <br /> sTy�FOHAN�OP <br /> F OF CA��FO <br /> 08 7 <br /> M6.01 <br /> (r�;l <br /> �L J/ CLIENT <br /> KIPP:PUBLIC SCHOOLS NORTHERN CALIFORNIA <br /> PROJECT NUMBER <br /> P2102201 AR <br /> a I—I DATE: 07/01/2021 <br /> W <br /> DRAWN BY: KF CHECKED BY: RT <br /> REVISIONS <br /> () # DESCRIPTION DATE <br /> Q (E)12"x12" EA UP—/ <br /> C 5 <br /> 2i <br /> 00 <br /> ca <br /> 00 <br /> U) <br /> I� <br /> -4 <br /> °>° CONSTRUCTION DOCUMENTS <br /> 0 <br /> CDQ <br /> MECHANICAL <br /> N <br /> N <br /> O <br /> ROOF PLAN <br /> N N <br /> U � <br /> Q co N <br /> COU <br /> U � <br /> � N <br /> O <br /> N <br /> o MECHANICAL ROOF PLAN <br /> NSCALE: 1/4" = 1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.