COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 11:11:37 AM
Creation date
1/25/2022 9:32:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for MARCH LANE 76 * as of February 18 , 2022 . <br /> Open violations from December 16 , 2021 inspection <br /> Violation #104 = Failure to have an approved UST Monitoring Plan . <br /> OBSERVATION : The monitoring plan is not approved by the EHD . The following items need to be <br /> addressed/corrected : <br /> -The Tank Overfill Prevention is checked off as "audible/visual alarms" and "fill tube shut-off valve" but the additional <br /> comment section lists that ball floats are used ("Overfill prevention : External AN alarm set at 90 % tank capacity and <br /> ball floats" ) . This additional comment/information does not match what is checked off. ( Ball floats were removed <br /> during 11 /12/2021 overfill prevention testing ) . <br /> -For all three tanks Under Dispenser Containment ( UDC) Monitoring lists the following incorrect information : <br /> * UDC Panel Manufacturer: Veeder-Root (floats and chains do not have a panel ) <br /> * UDC Panel Model : #TLS 350 (floats and chains do not have a panel ) <br /> * UDC Leak Sensor Model : Bravo (should be floats and chains) <br /> REGULATION GUIDANCE : The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS ) . <br /> CORRECTIVE ACTION : Immediately log into CERS , make the necessary changes , and submit for review by the <br /> EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #107 - Failure to submit and maintain complete and current financial responsibility documents . <br /> OBSERVATION : Financial responsibility documents have not been submitted to the EHD . The most recent <br /> financial responsibility documents in CERS are dated 12/16/2019 . <br /> REGULATION GUIDANCE : Current financial responsibility documents are required to be submitted annually. <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System (CERS) at <br /> http ://cers . calepa . ca .gov/, and upload the required documents . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.