My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2022 4:49:35 PM
Creation date
1/27/2022 8:11:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO STATION#83560` 2908 W BENJAMIN HOLT DR, STOCKTON J,3i u . <br /> File Review <br /> 121 HSC 25299(a)(8), False statements,representation,or certification made on an application.record,or other document V R COS <br /> 25299(b)(7) <br /> 122 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report -V -R COS <br /> On Site Records <br /> 201 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance -V -R -COS <br /> 202 CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility -V -R COS <br /> 203 CCR 2712(b)(1-2) Failure to maintain monitoring records for 36 months and maintenance records for 60 months V R COS <br /> 204 CCR 2712(b)(6) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST V R COS <br /> 205 CCR 2712(1) Failure to have current UST Monitoring Plan readily accessible at the facility V R COS <br /> 206 CCR 2712(i),2634(e) Failure to have a current UST Response Plan available on site « V R COS <br /> 207 CCR 2716(f) Failure to maintain designated operator inspection reports and all attachments on site for 36 months V R COS <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements ■V ■R _COS <br /> 209CCR 2715(c)(3), Failure to maintain a copy of the"Facility Employee Training Certificate"on-site V _R COS <br /> 715(c)(4) <br /> 210 CCR 2715(c) Failure to provide initial training,train every 12 months,and have a trained employee present V R COS <br /> 211 CCR 2715(c)(2) Failure to have or implement a training programapproved by the UPA,at an unstaffed facility -V R -COS <br /> 212 CCR 2651;HSC 25294 Failure to record any unauthorized release from primary containment V R COS <br /> 213 CCR 2650(e),2652 Failure to notify and submit report of reportable unauthorized release or record release V R COS <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions V R COS <br /> 215 CCR 2715 Designated operator,service tech,or installer did not possess current certifications V -R COS <br /> 216 HSC 25281.5(b)(2) Failure to meet inspection requirements for marina unburied fuel piping V R COS <br /> 217 HSC 25281.5(b)(3) Failure to meet inspection requirements for emergency generator unburied fuel piping V R COS <br /> UST System Observations <br /> 301 HSC 25292.1(a) Failure to operate UST system to prevent unauthorized releases including leaks,spills and overfills V R COS <br /> 302 CCR 2630(d),2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest opportunity -V _R COS <br /> 303 CCR 2630(d),2641(a) Failure to maintain piping to allow liquid to flow into sump(i.e.failure to remove test boots) -V -R COS <br /> 304 CCR 2631(a);HSC Failure to construct,operate,and maintain primary containment as product-tight V R COS <br /> 25290.1(c) <br /> 305 HSC 25290.1,25290.2, Failed to maintain secondary containment(e.g.failure of secondary containment testing) V R COS <br /> 25291 <br /> 306 HSC 25291(e) Failure to remove,analyze,and properly dispose of water in secondary containment(pre-Jul 2003) V R - COS <br /> 307 HSC 25290.1(c3), Failure to keep water out of the secondary containment system(post-Jul 2003) V R COS <br /> 25290.2(c3) <br /> 308 CCR 2632(c),2634(d), Failure of the leak detection equipment to have an audible and visual alarm ■V ■R ■COS <br /> 2636(f) <br /> 309 CCR 2666(b)(2), Failure to have continuous monitoring that activates audible-visual alarm or stops flow at dispenser V R -COS <br /> 2636(f)(1) <br /> 310 CCR 2636(f)(4) Failure to meet monitoring requirements in lieu of being tightness tested every 12 months -V -R -COS <br /> 311 HSC 25291(b) Monitoring system incapable of detecting leak into secondary containment(pre-Jul 2003) V R COS <br /> FA0003625 PR0231021 SC001 01/26/2022 <br /> EHD 23-01 Rev.12/06/2021 Page 2 of 5 Underground Storage Tank Program OR <br /> rsi:E?c:_ Hazelton �w�rnr�r> Stockton, C, T( 9 20 ( T l ;9��=t :- J [ ,��) lfa {:! 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.