Laserfiche WebLink
S' AN JOAQUIN Environli'iental Health Dein 1-1,rtnni'?'i 1 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date <br /> ARCO STATION #83560* 2908 VV BENJAMIN HOLT DR, STOCKTON January 26, 20221 <br /> UST System Observations <br /> 312 HSC 25290.2(d) Monitoring system incapable of detecting entry into secondary containment(Jul 2003-Jun 2004) -V R COS <br /> 313 HSC 25290.1(d) Monitoring system incapable of detecting entry into secondary containment(post-Jul 2004) V - R COS <br /> 314 CCR 2631(g),2632(c) Failure to continuously monitor interstitial space with audible-visual alarm system(pre-Jul 2004) -V R COS <br /> (2) <br /> 315 HSC 25290.1(e) Failure to maintain interstitial space to detect leaks before release to environment(post-Jul 2004) V R COS <br /> 316 CCR 2636,2643(c)(1), Failure to install a line leak detector -V R COS <br /> 2666(f) <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow V R COS <br /> 318 CCR 2635,2637.1, Failed to meet spill container requirements V R COS <br /> 2665,2712 <br /> 319 CCR 2635,2637.2, Failure to comply with overfill prevention equipment requirements V R COS <br /> 2665, <br /> 2712 <br /> 320 CCR 2635(c)(1) Overfill prevention was overridden V R COS <br /> 321 HSC 25299(a)(9) Leak detection equipment disabled or tampered with V R COS <br /> 322 CCR 2717.1(g) Removed,defaced,altered,or otherwise tampered with red tag V R COS <br /> 323 `CCR 2717.1(f);HSC Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST -V R COS <br /> 25292.3(c) <br /> 324 HSC 25292.3(c)(1)(C) Allowed dispensing from a LIST that has a red tag affixed to the fill pipe -V R COS <br /> 325 CCR 2635,2636(b), Failure to comply with the cathodic protection system requirements V R COS <br /> 2662,2712 <br /> 326 CCR 2631(b&d), Primary and/or secondary containment not constructed in accordance with the established standards V R COS <br /> 2666(b&e) <br /> 327 CCR 2638(a),26410) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions V R COS <br /> 328 CCR 2630,2632,2643, Equipment or methods used to monitor the LIST system are not certified by an independent third-party V R COS <br /> 2644.1 <br /> 329 CCR 2631.1,2660(m) UST system not compatible with the substance stored V R COS <br /> 330 CCR 2636(f),2666(c), Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm V -R COS <br /> 2666(f) <br /> 331 HSC 25281.6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions V R COS <br /> 332 HSC 25283.5(a) Failure of unburied below-grade UST system to meet exemption conditions V - R COS <br /> 333 CCR 2666(b)(2) Failure to upgrade single-wailed pipe to double-walled interstitially monitored pipe when repaired V R COS <br /> 334 CCR 2670(b)(e)(f), Failure to comply with temporary closure requirements V R COS <br /> 12671 <br /> 335 HSC 25298(c);CCR Failure to comply with all permanent closure requirements V R COS <br /> 2670,2672 <br /> 336 CCR 2638(f),26410) Failure to affix a tag/sticker on each monitoring equipment certified,repaired,or replaced V R COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Safe suction piping not properly sloped or check valve incorrectly located V R COS <br /> 2641(b) <br /> 402 CCR 2643(d) Failure to conduct monitoring and maintain records for single-walled conventional suction(pre-1984) V -R -COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph integrity test for single-walled conventional suction systems(pre-1984) V R COS <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) c V -R COS <br /> FA0003625 PR0231021 SCO01 01/2612022 <br /> EHD 23-01 Rev.12/06/2021 Page 3 of 5 Underground Storage Tank Program OIR <br /> F <br /> fltorl Avcnu�� <br />