My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0084741_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
7070
>
2600 - Land Use Program
>
SR0084741_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2022 4:16:00 PM
Creation date
2/1/2022 1:42:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0084741
PE
2602
FACILITY_NAME
7070 S HARLAN RD
STREET_NUMBER
7070
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19309001
ENTERED_DATE
1/18/2022 12:00:00 AM
SITE_LOCATION
7070 S HARLAN RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />Therefore, the wastewater alone supplies almost a sufficient alkalinity concentration for <br />nitrification of the effluent. From the soil tests, nitrification appears to be inhibited at the deeper <br />depths that may be attributable to the alkaline soil pH. <br />E. SURFACE WATER INFORMATION AND CALCULATIONS <br />NLS§ 3.2. The rainfall recharge factor used in the Hantzsche-Finnemore equation below will be <br />based upon water balance documentation from Norman Hantzsche found in Appendix E, which <br />pertains to the entire Stockton and outlying areas. <br />III. NITRATE LOADING STUDY FINDINGS <br />A. WASTEWATER FLOW VOLUME PROJECTIONS AND CHARACTERISTICS <br />Wastewater Flow Volume Projections <br />To determine nitrate-nitrogen loading from any project, wastewater flow volumes must be <br />determined as accurately as possible. The maximum number of onsite people who can occupy the <br />facility after completion of the proposed addition, is 37. The EHD has specified 60 <br />gals/person/day from the Water Use Computation Factor Table and from personal communication. <br />Consequently, the Average Daily Flow is: 37 x 60 = 2,220 gallons per day (gpd). This value is <br />discussed in further detail in the Conclusions and Recommendations Section of this Report. <br />Wastewater Characteristics <br />The domestic wastewater generated from the Facility will be composed of blackwater from toilets <br />and greywater from showers, laundry, hygiene, food prep, etc. . <br />To utilize accurate nitrogen concentrations in the nitrate loading calculations, a septic tank effluent <br />sample was retrieved from the second compartment of the 3,600 gallon tank which serves the HOP <br />facility. The test results are summarized below in Table 5 and found in Appendix F. <br />TABLE 3 <br />HOP FACILITY SEPTIC TANK EFFLUENT SAMPLING TEST RESULTS <br />SAMPLE <br />ID <br />BIOCHEMICAL <br />OXYGEN <br />DEMAND <br />(BODO <br />TOTAL <br />SUSPENDED <br />SOLIDS <br />(TSS) <br />TOTAL <br />KJELDAHL <br />NITROGEN <br />(TKN) <br />AMMONIA <br />NITROGEN <br />NH4 <br />ORGANIC <br />NITROGEN <br />(Cale.) <br />TOTAL <br />ALKALINITY <br />pH <br />7070 <br />Harlan <br />Rd. <br />300 mg/L 250 mg/I. 67.4 mg/I. 44.5 mg/I. 22.9 mg/L 472 mg/I. 6.94 <br />Typically, organic nitrogen concentrations in septic tank effluent are 25% to 33% of the Total <br />Kjeldahl Nitrogen (TKN) concentrations, which was observed from the test results. The TKN value <br />of 67.4 mg/L will be used in the nitrate loading calculations below. <br />Page -5- <br />Chesney Consulting
The URL can be used to link to this page
Your browser does not support the video tag.