Laserfiche WebLink
nuiy , G� SAN J OAQ U I N Environmental Health Department <br /> N /Li <br /> ~ COUNTY <br /> Greatness grows here . <br /> Jasjit Kang , REHS , Director <br /> .. .. ��% Muniappa Naidu, REHS, Assistant Director <br /> "gLIFOR?' <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> February 9 , 2022 <br /> Jamie Barnes <br /> Western Pump , Inc <br /> 3235 F Street <br /> San Diego , CA 92102 <br /> Re : Love ' s Travel Shop SR0084412 <br /> 1553 Colony Rd , Ripon , CA 95366 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace existing under dispenser containments sumps ( UDC) <br /> • Replace existing product piping <br /> • Replace existing UDC sensors <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust( slgov . org to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments ) . <br /> a . Witness water and/or soil sampling under removed UDCs and piping . <br /> b . Primary piping soap test of all piping and penetrations ( product) : One- hour pneumatic <br /> pressure test at 110 % of operating pressure , or 40 psi , whichever is greater, in <br /> accordance with manufacturer' s instructions . <br /> c . Secondary piping soap test of all piping and penetrations ( product) : One - hour pressure <br /> test at the manufacturers recommended specification . <br /> d . Verification of secondary piping slope , at 1 /8 inch per foot or greater, to a containment <br /> sump with an audible/visual alarm . <br /> e . Verification of all pipe setbacks , crossovers , and burial depth according to the <br /> manufacturer' s installation instructions . Verification of appropriate piping backfill . <br /> f. Integrity testing of all UDCs per the manufacturer' s installation instructions . <br /> g . UDC Sensor functionality : Functionality of the monitoring system must be verified to <br /> ensure that monitoring has been restored to meet the requirements of Title 23 California <br /> Code of Regulations and the Health & Safety Code . If it is determined that a cold start <br /> is necessary , a copy of the alarm history shall be printed prior to performing the " cold <br /> start" of the Veeder Root system and made available at the time of EHD inspection . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 1 F 209 464 - 0138 1 www. sjgov . org/ehd <br />