My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2025 4:00:04 PM
Creation date
2/10/2022 9:06:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0516526
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0012659
FACILITY_NAME
LOVES COUNTRY STORES OF CALIFORNIA #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1553 COLONY RD RIPON 95366
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 13 Confined Space Program <br /> new hazard has been created and/or if special deviations have occurred . Training must be <br /> documented . <br /> Rescue <br /> • No entry rescue shall be permitted of Western Pump , Inc. employees . <br /> • Employees will utilize 911 or on base fire/ems services for any and all confined <br /> space rescues . <br /> • The rescue service shall be notified prior and given a chance to evaluate the space <br /> and practice rescue prior to entry . <br /> Pre-entry <br /> The applicable provisions of this subsection shall be implemented before entry into a <br /> confined space . <br /> • Lines which may convey flammable , injurious , or incapacitating substances into the <br /> space shall be disconnected blinded or blocked off by other positive means to <br /> prevent the development of dangerous air contamination and/or oxygen deficiency <br /> within the space . The disconnection or blind shall be so located or done in such a <br /> manner that inadvertent reconnection of the line or removal of the blind areeffectively <br /> prevented . Exception: This does not apply to public utility gas distribution systems. <br /> Note: This subsection does not require blocking of all laterals to sewers or storm <br /> drains. Where experience or knowledge of industrial use indicates materials resulting <br /> in dangerous air contamination may be dumped into an occupied sewer, all such <br /> laterals shall be blocked. <br /> • The space shall be emptied flushed or otherwise purged of flammable , injurious or <br /> incapacitating substances to the extent feasible . <br /> • The air shall be tested with a calibrated Gas Meter. A written record of such testing <br /> results shall be made on the Confined Space Checklist and kept at the work site for <br /> the duration of the work . <br /> o Never enter the space to conduct the air test. It is the best practice to sample the <br /> space with a probe through the weep hole initially, to prevent exposure to <br /> potentially dangerous or deadly vapors that may have built up under the man hole <br /> cover. <br /> o Once it has been determined safe to open the confined space , the remote sampling <br /> tube may be lowered into the space or the meter may be lowered on a rope . A <br /> thorough sampling of the space at the lowest level , a mid point and towards the top <br /> is necessary because gasses may stratify in the space . That is , some gasses are <br />
The URL can be used to link to this page
Your browser does not support the video tag.