Laserfiche WebLink
Soil Suitability and Nitrate Loading Study <br />FAIST PROPERTY <br />6631 South Jack Tone Road, Stockton, California <br /> <br />TABLE OF CONTENTS <br /> <br /> <br />SECTION PAGE <br /> <br />1.0. INTRODUCTION AND PROPOSED DEVELOPMENT ......................................... 1 <br />1.1. DESCRIPTION OF SITE .................................................................................... 1 <br />1.2. DESCRIPTION OF PROPOSED DEVELOPMENT ........................................... 2 <br />1.3. PARCEL VICINITY LOCATION MAP ................................................................. 2 <br />1.4. SITE MAP .......................................................................................................... 2 <br />2.0. PRESENT AND PAST USAGE OF SITE .............................................................. 2 <br />2.1 POTENTIAL SITE PROBLEM ASSESSMENT .................................................. 2 <br />3.0. EXISTING AND PROPOSED SEPTIC TANK USAGE ......................................... 3 <br />3.1. EXISTING ON-SITE SEPTIC TANK USAGE ..................................................... 3 <br />3.2. SITE SEPTIC PERMIT HISTORY ...................................................................... 3 <br />3.3. ON-SITE SEPTIC TANK REPAIR HISTORY ..................................................... 3 <br />3.4. EXISTING SEPTIC TANK USAGE IN THE GENERAL AREA ........................... 4 <br />3.5. GENERAL AREA SEPTIC PERMIT HISTORY .................................................. 4 <br />3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE ............................... 5 <br />4.0. GROUNDWATER INFORMATION - REGIONAL HYDROGEOLOGY ................. 5 <br />4.1. GROUNDWATER DESCRIPTION FOR THE GENERAL AREA ....................... 5 <br />4.2. GROUNDWATER CONTAMINATION IN THE AREA OF THE SITE ................. 6 <br />4.3. ON-SITE EXISTING WELL DESCRIPTION ....................................................... 6 <br />5.0. SOIL PROFILE ..................................................................................................... 6 <br />5.1. SOIL PROFILE PIT INCLUDING DEPTH AND DIMENSIONS .......................... 7 <br />5.2. SOIL LITHOLOGY AS RELATED TO FUTURE ONSITE SEPTIC USES .......... 7 <br />6.0. PERCOLATION TEST INFORMATION ................................................................ 7 <br />6.1. NUMBER OF PERCOLATION TESTS PERFORMED ....................................... 7 <br />6.2. CONSTRUCTION OF PERCOLATION TEST HOLE ......................................... 7 <br />6.3. DESCRIPTION OF THE PERCOLATION TEST HOLE - POST SOAK ............. 8 <br />6.4. PERCOLATION TEST CONFORMED TO SJC POLICY EHD 98-02 ................ 8 <br />6.5. COMPLETED PERCOLATION TEST FORM..................................................... 8 <br />6.6. POTENTIAL PROBLEMS PREDICTED ............................................................. 8 <br />6.7. PERCOLATION TEST FINDINGS ..................................................................... 8 <br />7.0. CHEMICAL AND PHYSICAL PROPERTIES OF SOIL ........................................ 9 <br />7.1. CHEMICAL AND PHYSICAL PROPERTIES OF SITE SOILS ........................... 9 <br />7.2. MASS TRANSPORT PROPERTIES OF UNDERLYING SITE SOILS ............... 9 <br />8.0. GROUNDWATER ANALYSIS .............................................................................. 9 <br />8.1. DESCRIPTION OF LOCAL GROUNDWATER .................................................. 9 <br />8.2. EXISTING OR POTENTIAL GROUNDWATER CONTAMINATION ................ 10 <br />8.3. CURRENT AND FUTURE USE OF GROUNDWATER AT THE SITE ............. 10