Laserfiche WebLink
9. AST will withstand Trost-heave XX Yes No AST is located in secured covered Service Area <br /> not subject to weather conditions <br /> 10. AST previously relocated? Yes XX No <br /> 11. AST Corrosion Protection Tank is covered in paint, with no evidence of external corrosion. Tank has no <br /> Specific corrosion protection beyond the paint. No part of the AST touches the ground. The base of the AST <br /> is steel,raised 4 inches within the berm. The berm is raised 1 1/z in, above concrete pad. There is no evidence <br /> of internal corrosion taking place. Tank's construction material is carbon steel. Since this tank is not in <br /> contact with the ground, there is no need for further corrosion protection such as cathodic corrosion <br /> rotection. <br /> 12. AST Spill Prevention Equipment Tank has secondary containment with single wall steel horizontal cylinder <br /> priniary tank set in a steel berm.Tank has unknown brand mechanical float level gauge to determine product <br /> levels in primary vessel. Fillina operations conducted by connecting directly to oil caddies in service area,via <br /> quick connect device, pumping product into AST. Filling is remote operation. Product is not normally T <br /> handled outside of its intended containers. There is slight waste oil residue on the berm floor from s ilia e <br /> which should be removed and the berm should be kept clear from debris and standina oil. <br /> 13. Overfill Protection: System has mechanical float unknown brand gauge for product levels determination. <br /> Pump has manual ball valve shut off for emergency shut off of pumping operations. Fil in�,i„,. <br /> lE 's remote from <br /> pneumatic pump-product not normally handled outside of intended containers. The manual ball valve was <br /> inspected, and found to be in the open position. Daily inspections should be conducted to ascertain product <br /> to this levels in the primary tank. A Daily Loa example for visual inspections is attached , assessment <br /> ,. <br /> is assessment report. <br /> The tank has a containment filling,basin on the top of the tank to capture oil from filters and allow the oil <br /> filters to drain into the tank thru the 2 in. pipe connected bottom of the containment basin. <br /> 14a: Toxic Considerations: Used mineral-based crank brown-to-black, ly <br /> case oil is the ,oily liquid removed from <br /> the engine of a motor vehicle when the oil is changed.It is similar to unused oil except it contains additional <br /> chemicals from its use as an engine lubricant.The chemicals in oil include hydrocarbons, which are distilled <br /> from crude oil, and various additives that improve the oil's performance.Used oil also contains chemicals <br /> formed when the oil is exposed to high temperatures and pressures inside an engine.It also contains some <br /> metals from engine parts and small amounts ofgasoline, antifreeze and chemicals that come from gasoline <br /> when it burns inside the engine. <br /> 14b: Additional Hazardous Considerations: Waste Oil can be Ignitable & create fires under certain conditions <br /> are combustible or have a flash point less than 60 °C 140 ° in addition to a slightly corrosive hazard. which <br /> can corrode & break down metals over long periods of exposure. It is not normally a reactive nor does it <br /> enerate large amounts of vapors,which would be an additional fire hazard however,this tank is not fitted <br /> with one 2 in. atmos heric vent on the primary tank and no atmospheric vent on the secondary containment <br /> area. The tank has no emergency vent on the priniar-Y tank, and also no emergency vent on the secondary <br /> containment. Emergency vents,if installed, are properly sized as annotated on a Nameplate on the exterior <br /> of the tank,and/or also for the listing thru Underwriter's Laboratories.. <br /> 15. AST secondary containment (material/design/listed) AST has secondary containment via steel berm to <br /> completely capture any leaks from primary vessel. Secondary containment was tested,is intact and AST is <br /> suitable for continued usa e. AST sits within a secured Service Area room enclosure . Leak detectionctiotion is <br /> visually ascertained via visual inspection of secondary containment area. Berm has 710 gal. capacity for <br /> containment. <br /> 16. Damage to AST or systems. No damage reported by Owner/Operator. Upon inspection,no evidence of <br /> weld breaks unctures cracks or other structural damage to the tank. Leak detection is assured via <br /> inspections of the secondary containment. Steel thickness measured to.140 in. average measured at 20 points <br /> on AST outer shell with ultrasonic steel thickness sensor& .130 in. averagov on outer berm steel walls avers e�T <br /> measured at 20 points on berm walls with ultrasonic steel thickness sensor. <br />