My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
4600
>
2300 - Underground Storage Tank Program
>
PR0547496
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 4:28:46 PM
Creation date
2/17/2022 9:06:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0547496
PE
2351
FACILITY_ID
FA0027003
FACILITY_NAME
VALLEY FUELS INC
STREET_NUMBER
4600
Direction
S
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
24402031
CURRENT_STATUS
01
SITE_LOCATION
4600 S CORRAL HOLLOW RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY <br /> 6 . The UST system must be installed in compliance with all of the following : <br /> a . The installed UST system must be compliant with all applicable laws , regulations , and industry <br /> standards . All installation and testing shall be in compliance with manufacturer' s instructions and <br /> CCR 2635 and 2636 . All monitoring system components shall be listed in the State Water <br /> Resources Control Board ' s Local Guidance Letter ( LG ) 113 . <br /> b . All primary containment including any integral secondary containment system must be certified by <br /> an independent testing organization and labeled as required by the organization ( California Code <br /> of Regulations Title 23 Chapter 16 ( CCR ) 2631 ( b) ; UL , ULC , ANSI , API , ASTM , etc . See CCR <br /> Table B for complete list . ) . Pursuant to Underwriters Laboratories Inc . ( UL) listing requirements , <br /> only those products bearing the UL mark will be considered listed . ANY PART/PRODUCT NOT <br /> MARKED WITH THE UL LABEL OR ANOTHER LISTED TESTING ORGANIZATION WILL BE <br /> REJECTED . All secondary containment system which is not an integral part of the primary <br /> containment shall be designed and constructed according to an engineering specification <br /> approved by a state registered professional engineer or according to a nationally recognized <br /> industry code or engineering standard , per CCR 2631 ( d ) . <br /> c . All metal components in direct contact with the ground , such as flexible connectors , swing joints , <br /> fittings , clamps , bands , and pumps , shall have adequate corrosion protection . <br /> d . Install concrete of sufficient thickness over USTs and around sumps and dispensers , according to <br /> the manufacturer' s written installation instructions and buoyancy calculations . <br /> e . All tank top openings that are connected to the primary space of the UST must have secondary <br /> containment , audible/visual alarm , and be vapor tight or terminate at grade . <br /> f. Sumps , including UDCs , must be constructed in a manner to prevent vapors from entering the <br /> backfill . <br /> g . All secondary containment must be constructed to prevent water intrusion and must be <br /> continuously monitored as required under HSC 25290 . 1 . <br /> h . Chase piping must be VPH monitored and included in its respective product piping vacuum <br /> monitoring zone . All vacuum zone volumes must be accurately programmed and their volumes <br /> adequate for their respective vacuum sensors . All sensors must be installed to detect a leak at <br /> the earliest opportunity . <br /> i . Overfill prevention shall satisfy CCR 2635 ( b ) (2 ) ( C ) , pursuant to the permit application . No ball <br /> floats shall be installed on vent lines to comply with overfill prevention requirements ( Code of <br /> Federal Regulations , Title 40 , section 280 . 20 ( c) ) <br /> j . Hazardous material or waste cannot be released , intentionally or unintentionally , to the <br /> sewer/septic system , storm water system , or any other waters of the state . If a release occurs , it <br /> will be considered illegal hazardous waste disposal and will be subject to enforcement . <br /> k . No additional shut off valves should be installed between the monitored interstitial spaces <br /> and their respective sensors . <br /> PRIOR TO FIRST FUEL DELIVERY : <br /> 7 . A valid California Department of Tax and Fee Administration ( CDTFA) number must be obtained and <br /> provided to EHD prior to fuel drop . This number must be uploaded into the California Environmental <br /> Reporting System ( CERS ) at https : //cers . calepa . ca . gov . <br /> 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.