My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
4600
>
2300 - Underground Storage Tank Program
>
PR0547496
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 4:28:46 PM
Creation date
2/17/2022 9:06:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0547496
PE
2351
FACILITY_ID
FA0027003
FACILITY_NAME
VALLEY FUELS INC
STREET_NUMBER
4600
Direction
S
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
24402031
CURRENT_STATUS
01
SITE_LOCATION
4600 S CORRAL HOLLOW RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAOUIN <br />COUNTY <br />F. SYSTEM PIPING CONTINUED: <br />Environmental Health Department <br />Check <br />Code <br />Box <br />Section <br />Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br />N/ <br />HSC <br />25290.1 c 1 <br />Piping compatible with material intended to be stored. <br />25290.2 c 1 <br />Approved overfill prevention device provided at each tank fill location. <br />f� <br />23 CCR <br />2631(b) <br />Design and construction of piping approved by independent testing organization (e.g. UL). <br />2636(b) <br />Piping, including vent lines, sloped toward tank(s) with minimum 1/8 inch slope per 1 foot of run. <br />triggering an audible visual alarm <br />HSC <br />25290.1 k <br />Vapor recovery, fill riser, and vent line piping are secondarily contained. <br />V, <br />25290.2�c;&0) <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br />G. OVERSPILL/ OVERFILL PREVENTION: <br />Check <br />Box <br />Code <br />Section <br />Box <br />23 CCR <br />Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br />N/ <br />2635(b) <br />Manufacturer OPW Model 6571 EVRB <br />Approved overfill prevention device provided at each tank fill location. <br />23 CCR <br />Choose One of the following methods: <br />2636(b) <br />❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br />triggering an audible visual alarm <br />❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br />23 CCR <br />2635(a)(2) <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br />23 CCR <br />2635(b)(2) <br />audible alarm at least five minutes before the tank overfills <br />❑ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br />capacity. <br />❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br />tank are exposed to product due to overfilling. <br />Manufacturer OPW Model 71SO-41OCT <br />H. CORROSION PROTECTION: <br />Check <br />Code <br />Box <br />Section <br />Fiberglass reinforced plastic (FRP) <br />Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br />23 CCR <br />❑ Steel isolated from contact with backfill <br />2636(b) <br />'YrFRP or equivalent non-metallic exterior coatings or coverings <br />Tank corrosion protection: ❑ Sacrificial Anode <br />23 CCR <br />2635(a)(2) <br />❑ Steel tank with field installed cathodic protection or impressed <br />current <br />Tie -downs, when used, constructed of non -corrosive material or coated steel. <br />7 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.