My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
4600
>
2300 - Underground Storage Tank Program
>
PR0547496
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 4:28:46 PM
Creation date
2/17/2022 9:06:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0547496
PE
2351
FACILITY_ID
FA0027003
FACILITY_NAME
VALLEY FUELS INC
STREET_NUMBER
4600
Direction
S
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
24402031
CURRENT_STATUS
01
SITE_LOCATION
4600 S CORRAL HOLLOW RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />I. MONITORING: All monitoring equipment must be listed in the State Water Resources Control Board <br />Division of Clean Water Program Local Guidance Letter 113. <br />Check <br />Box <br />Code <br />Section <br />MODEL <br />COMPOSITION <br />SUMP <br />All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br />Xerxes <br />23 CCR <br />under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br />❑ <br />2636(f) <br />detection systems. <br />PENETRATIONS <br />Smith FRP <br />Electronic monitoring sensors located at the following points: <br />=FRP <br />° At the bottom of the interstitial space of each secondarily -contained tank, <br />positioned as near as possible to the bottom of the tank. <br />Manufacturer Veeder-Root Model 794380-303 <br />° In each collection sump, positioned as near as possible to the bottom of the <br />collection sump. Additionally, in any sump acting as secondary containment for <br />unused tank openings which connect to the primary space. <br />Kii 8 �� <br />Manufacturer Veeder-Root Model 330020-536 <br />❑ ❑ <br />23 CCR <br />2632 <br />2630(d) <br />° In dispenser pans which do not drain into secondary containment piping. (Note: <br />A mechanical switch which triggers a shear valve may be substituted but this <br />system will not qualify for the annual line tightness test exemption under 23 CCR <br />2636(8)). <br />h,& A �a <br />Manufacturer Veeder-Root Model 330020-536 <br />❑ Along secondarily -contained pipe runs which do not meet the 1/8 inch -per -foot <br />slope requirement, positioned in the depressed or low-lying areas. <br />Manufacturer Veeder-Root Model 330020-536 Y <br />23 CCR <br />Automatic line leak detectors installed to monitor underground pressurized piping. <br />2636(f) <br />❑ <br />HSC <br />Manufacturer Veeder-Root Model 848480-003 <br />25290.1 h <br />25290.2 <br />Alarm panel provides both audible and visual alarms. It is located in a protected area <br />and within sight and hearing distance of on-site personnel and hard -wired to a <br />❑ <br />❑ <br />23 CCR <br />2632(c)(2)(B) <br />dedicated circuit. <br />Manufacturer Veeder-Root Model TLS -350 <br />J <br />OTHER COMPONENT INFORMATION: <br />COMPONENT <br />MANUFACTURER <br />MODEL <br />COMPOSITION <br />SUMP <br />Xerxes <br />Xerxes <br />DW FRP <br />UNDER -DISPENSER <br />CONTAINMENT <br />Bravo <br />B8380 -D30 <br />DW FRP <br />PENETRATIONS <br />Smith FRP <br />1012030-626-0 <br />=FRP <br />8of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.