My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
5749
>
2800 - Aboveground Petroleum Storage Program
>
PR0515802
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 4:39:32 PM
Creation date
2/22/2022 8:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0515802
PE
2832
FACILITY_ID
FA0021241
FACILITY_NAME
TRACY MUNICIPAL AIRPORT
STREET_NUMBER
5749
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5749 S TRACY BLVD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY MUNICIPAL AIRPORT 5749 S TRACY BLVD,TRACY February 17, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 713 CFR 112.7(e), 112.8(c)(6) Failed to test or inspect each container for integrity based on industry standards. <br /> OBSERVATION: Facility failed to test each aboveground container for integrity based on industry standards, as <br /> discussed in the SPCC Plan: Section 2.11 (page 12)discusses an external Integrity inspection must be made every <br /> 20 years by a licensed inspector and are due for the certified inspection in 2020.A certified inspection was not <br /> observed on site. <br /> REGULATION GUIDANCE: REGULATION GUIDANCE: 112.8(c)(6)Test or inspect each aboveground container <br /> for integrity on a regular schedule and whenever you make material repairs.You must determine, in accordance <br /> with industry standards,the appropriate qualifications for personnel performing tests and inspections,the frequency <br /> and type of testing and inspections,which take into account container size, configuration, and design (such as <br /> containers that are: shop-built,field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or <br /> partially buried). Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br /> testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br /> testing.You must keep comparison records and you must also inspect the container's supports and foundations. In <br /> addition, you must frequently inspect the outside of the container for signs of deterioration,discharges,or <br /> accumulation of oil inside diked areas. Records of inspections and tests kept under usual and customary business <br /> practices satisfy the recordkeeping requirements of this paragraph. <br /> 112.7(e) Inspections,tests, and records. Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility. You must keep these written <br /> procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector,with the <br /> SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph. <br /> CORRECTIVE ACTION: Immediately conduct the necessary integrity testing on the 12,000-gallon Av gas tank and <br /> 10,000-gallon Jet A based on industry standards Integrity Test Standard of STI SP001. Maintain testing and <br /> inspection records. Submit a copy of the test/inspection results to the EHD. <br /> This is a repeat violation, Class II. <br /> 716 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> OBSERVATION: Test records for the liquid level sensing devices for the 12,000-gallon Av gas and 10,000-gallon <br /> JetA tanks were not observed for years 2019 and 2020. <br /> Additionally the only one annular sensor for JetA was listed in the Liquid Sensor Setup on the Veeder Root panel. <br /> An annular sensor was not observed on the Liquid Sensor Setup for Av Gas. During the inspection 2 sensors were <br /> observed, one on each tank. <br /> REGULATION GUIDANCE: (c)(8)(v)You must regularly test liquid level sensing devices to ensure proper <br /> operation. <br /> CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br /> regularly tested to ensure proper operation. Submit a statement indicating that all necessary testing of liquid level <br /> sensing devices to ensure proper operation are conducted. <br /> This is a repeat violation, Class II. <br /> FA0021241 PR0515802 SCO01 02/17/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 10 of 11 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />