° r I Environmental Health Department <br /> SAN-6-JOAQU <br /> CaLJT <br /> Greotness grows here. <br /> Food Program Service Request Inspection Report <br /> Facility Name and Address: CLUB RIO DE JANEIRO RESTAURANT, 315 S HUNTER ST, STOCKTON 95203 <br /> #34 Warewashing Facilites Maintained <br /> OBSERVATIONS:The 3-compartment sink does not have drain boards. Provide a 3-compartment sink with two(2)drain <br /> boards, one for soiled utensils and one for clean utensils. Correct prior to permit issuance. <br /> CALCODE DESCRIPTION:Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and <br /> materials shall be provided to measure the applicable sanitization method. (I14067(f,g), 114099, 114099.3, 114099.5, 114101(a), <br /> 114101.1, 114101.2, 114103, 114107, 114125) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:The functionality of the exhaust hood was not demonstrated during the inspection because former owner <br /> stated that it is in need of the routine servicing. Mechanical exhaust ventilation equipment shall be provided over all cooking <br /> equipment as required to effectively remove cooking odors, smoke, steam, grease, heat, and vapors.All mechanical <br /> exhaust ventilation equipment shall be installed and maintained in accordance with the California Mechanical Code. Makeup <br /> air shall be provided the rate of that exhausted. Correct prior to permit issuance. <br /> ----------------------------------------------------------------------------------------------------------------------------------------------------------- <br /> The functionality of existing hot and cold holding equipment was not demonstrated during the inspection.All manufactured <br /> and custom-made food service equipment must be certified for sanitation by an American National Standards Institute <br /> (ANSI)accredited certification program. Provide prior to permit issuance. <br /> ---------------------------------------------------------------------------------------------------------------------------------------------------------- <br /> The fire suppressant will need to be approved by the fire department. Provide proof prior to permit issuance. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Observed the kitchen was lacking sufficient lighting. Provide enclosed light fixtures, or shatterproof <br /> shields for light fixtures, over all areas where food is prepared, utensils cleaned, or open food is stored.The lighting should <br /> be sufficient to produce the following light intensity: a.) Fifty(50)foot candles, as measured thirty(30)inches off the floor, in <br /> any room in which food is prepared, manufactured, processed, or packaged. b.)Twenty(20)foot candles where food is self <br /> served, stored in refrigerators, or at dry storage, handwashing,warewashing, equipment and utensil storage areas, and <br /> toilet rooms. c.)Ten (10)foot candles at walk-in refrigeration units or dry storage area. Correct prior to operation. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft,or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored,served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> FA0001771 SR0084902 SC061 02/23/2022 <br /> EHD 16-23 Rev.09/16/2020 Page 2 of 4 Food Program Service Request Inspection Report <br />