Laserfiche WebLink
SAN 10AQ U I N Environmental Health Department <br />COUNTY <br />Aboveground Petroieum Storage Act Inspection Report <br />Facility Name: Facility Address: Date: <br />LIONUDAKIS FIREWOOD 20451 MCHENRY AVE. ESCALON February 22, 2022 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item Remarks <br />605 CFR 112.7(a)(3), 25270.4.5(a) Plan failed to include an adequate facility diagram, or no facility diagram was <br />included. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to Include an adequate <br />facility diagram. Transfer area and piping were missing from the facility diagram. <br />REGULATION GUIDANCE: (3) Describe in your Plan the physical layout of the facility and Include a facility diagram, <br />which must mark the location and contents of each fixed oil storage container and the storage area where mobile or <br />portable containers are located. The facility diagram must identity the location of and mark as "exempt" underground <br />tanks that are otherwise exempted from the requirements of this part under § 112.1(d)(4). The facility diagram must <br />also include all transfer stations and connecting pipes, includ ng intra -facility gathering lines that are otherwise <br />exempted from the requirements of this part under § 112.1(d)(11). <br />CORRECTIVE ACTION: Ensure that the SPCC plan inc udes a complete fa4ility diagram. Provide proof of CPr r� <br />correction to the EHD. 3)%4 <br />Thm is a repeat violation, Class II <br />610 CFR 112.7(a)(3vi), 112.7(x4) Plan failed to adequately detail information and procedures for reporting a discharge. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan does not adequately discuss <br />procedures for reporting a discharge. Cal OES phone number was incorrect in the SPCC plan. — <br />REGULATION GUIDANCE: The SPCC plan shall include: (vi) Contact list and phone numbers for the facility <br />response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br />response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br />described in § 112.1(b). <br />(4) Unless you have submitted a response plan under § 112.20, provide information and procedures in your Pian to <br />enable a person reporting a discharge as described in § 112.1(b) to relate information on the exact address or <br />location and phone number of the facility; the date and time of the discharge the type of material discharged; <br />estimates of the total quantity discharged estimates of the quantity discharged as described in § 112.1(b) the <br />source of the discharge; a description of all affected media; the cause of the discharge; any damages or injuries <br />caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge. whether an <br />evacuation may be needed; and the names of individuals and/or organ'zations who have also been contacted. <br />CORRECTIVE ACTION: Immediately amend the SPCC Plan to include procedures for reporting a discharge <br />Submit proof of correction to the EHD (� ls✓ <br />This is a minor violation <br />FA0010254 PRO523036 SCO01 02122/2022 <br />EHO 28-01 Rev 12106/2021 Page 6 of 9 Aboveground Petroleum Storage Act OR <br />1868 E Hazelton Avenge I Stockton. California 952051 T 209 468-3420 1 F 209 464-0138 1 www.slgov org/EHD <br />