Laserfiche WebLink
31 DRIVE-THRU CANOPY PLAN 21 KEYNOTES <br /> O1 BUILDING POINT OF ENTRY FOR 2" CW. <br /> O2 y <br /> BUILDING POINT OF ENTRY FOR 4" GREASE WASTE. am„14 <br /> T <br /> O3 BUILDING POINT OF ENTRY FOR 4" SANITARY SEWER. ` 0 � o <br /> N m <br /> x <br /> 12 O4 3/4" H/CW TO POST HYDRANT AT DUMPSTER PAD w >CD <br /> N <br /> O BUILDING POINT OF ENTRY FOR 4" GAS LINE FROM GAS METER. 1" GAS TO HEATER AT DRIVE THRU. FIELD DETERMINE FINAL ROUTING PRIOR TO BID & INSTALLATION. CD M <br /> x <br /> 60 PROPOSED JENSEN PRECAST 1,500 GALLON GREASE INTERCEPTOR AND SAMPLE BOX 2432Z. SEE SHEET P4.1 FOR DETAILS. 3" VENTS BACK TO BUILDING. `L <br /> L3 C/) M o <br /> O 1" GAS TO GAS HEATERS AT DRIVE THRU STATION. FIELD DETERMINE FINAL GAS ROUTING PRIOR TO BID & INSTALLATION. PROVIDE ELECTRIC SWITCH EMERGENCY GAS SHUT—OFF VALVE X � M <br /> TO HEATERS. v o <br /> 8 3/4" CW TO OUTDOOR HANDSINK. FIELD DETERMINE FINAL CW ROUTING PRIOR TO BID & INSTALLATION. O m <br /> O � N <br /> CD r— <br /> I T T-1O3"W TO OUTDOOR HANDSINK. FIELD DETERMINE FINAL WASTE LINE ROUTING PRIOR TO BID & INSTALLATION. 06' <br /> 10 1/2" GAS DOWN TO SUNPAK 25,000 BTU HEATER IN DRIVE—THRU CANOPY. SEE SHEET P6.1, DETAIL 3 FOR FURTHER SPECIFICATIONS. <br /> 11 1" GAS PIPE FROM METER. SEE PLUMBING SITE PLAN, DETAIL 1 FOR CONTINUATION. <br /> g3/4" CW PIPE. SEE PLUMBING SITE PLAN, DETAIL 1 FOR CONTINUATION. <br /> 13 3" W PIPE FOR OUTDOOR HANDSINK. SEE PLUMBING SITE PLAN, DETAIL 1 FOR CONTINUATION. <br /> 16 G11/2" H/CW PIPE TO OUTDOOR HANDSINK. <br /> Store: <br /> 15 2" ISLAND VENT FROM OUTDOOR HANDSINK. ROUTE VENT TO ROOF OF DRIVE—THRU CANOPY. KETTLEMAN & L. SACRMENTO <br /> ii I I ii O <br /> 14 16 EWH — ELECTRIC TANKLESS WATER HEATER UNDER THE COUNTER FOR OUTDOOR HANDSINK. SEE SHEET P6.1, DETAIL 3 FOR SPECIFICATION. LODI, CA 95242 <br /> HS-3 17 MIST AIR PUMP FOR MISTING SYSTEM AT DRIVE—THRU CANOPY. 1/2"CW PIPE TO PUMP. PROVIDE HIGH PRESSURE FLEX HOSE FROM PUMP TO STAINLESS STEEL MIST LINE AT DRIVE—THRU. Restaurant #RC576 <br /> SEE SHEET P6.1, DETAIL 3 FOR SPECIFICATION. <br /> 15 18 BRANCH 3/4" CW TO OUTDOOR HANDSINK; BRANCH 1/2"CW TO MIST AIR PUMP P4E-HV-M SCHEME A <br /> 19 PROPOSED SCHIER GB-50 GREASE INTERCEPTOR. Professional of Record: NAME <br /> 20 BUILDING POINT OF ENTRY FOR FIRE WATER LINE. <br /> 21 PROVIDE 4" ZURN 1090 BACKWATER VALVE, FLAPPER TYPE OR APPROVED EQUAL.. <br /> - I=mo_ ______________________ - <br /> Ji <br /> 13 PLUMBING SITE PLAN <br /> 1" = 20'-0" <br /> RoBISON <br /> ENGINEERING, INC <br /> 19401 40TH AVE W.,SUITE 302 <br /> LYNNWOOD,WA 98036 <br /> 206-364-3343 TEL <br /> REI# 424-1551 <br /> 0 <br /> I <br /> 4?OF.ESs/oN <br /> ROB;�F <br /> CLEAN CLEA CLEAN CLEAN <br /> A1W AIRI A1W AIPI <br /> VANPOOUEV VANPOOUEV VANPOOUEV VANPOOUEV <br /> O I z <br /> O o. M-2871 � <br /> SEE DETAIL 3 ON O O — - I E> — 0-21 <br /> THIS SHEET FOR <br /> ENLARGED VIEW _ _ O a> 9TF HAND <br /> 5 = a ® OF CAS\ <br /> 112 zwv� <br /> 12/21/20 <br /> 17 <br /> �„ o � - 21 <br /> 18 20 < ~o Lo 4 TV <br /> Prototype : P4E-HV 2020 -2.0 RELEASE <br /> w <br /> 1 w 0 ® I Prototype Issue Date: 7.14.2020 <br /> 1"G 9 I Des gn B l letn Updates <br /> -- <br /> z <br /> O I Date Issued: Bulletin Number: <br /> Wo <br /> ZZ <br /> oa <br /> I <br /> 1/2"G 1/2-G W <br /> 3 � W I 1ST BLDG. SUBMITTAL <br /> F ® Wo <br /> oZ <br /> ,:e:e:e:e:e <br /> 0 <br /> 10 10 <br /> dMm <br /> I I <br /> L_ I <br /> d011S REVISIONS: <br /> 12.22.2020 1st Building Submittal <br /> 1 <br /> 2 <br /> 3 <br /> o I 4 <br /> vs 5 <br /> 6 <br /> 7 <br /> 8 <br /> Sheet Title: <br /> PLUMBING SITE <br /> PLAN <br /> UTILITY CONTACT INFORMATION. PLUMBING SHEET INDEX Date: 12.07.2020 <br /> NOTE: EC TO COORDINATE WITH UTILITIES FOR ALL REQUIREMENTS AND RESPONSIBILITIES (INCLUDING BUT NOT LIMITED P1.0 PLUMBING SITE PLAN <br /> TO, TRENCHING, METERING, CONDUIT SIZE AND QUANTITY, FINAL LOCATIONS, ETC.) PRIOR TO BID & INSTALLATION. AND P1.1 WATER PLUMBING PLAN Project Number: RAC19048.0 <br /> MODIFY BID APPROPRIATELY TO INCLUDE ALL SCOPE OF WORK REQUIRED FOR A COMPLETE INSTALLATION. P1.2 WASTE & GREASE PLUMBING PLAN <br /> CONTACT NICOLE CAPLAN FOR MORE INFORMATION ON DRY UTILITIES SUCH AS POWER, TELEPHONE, & GAS. P2.1 ROOF PLUMBING PLAN Drawn By: - <br /> P3.1 WASTE, VENT & GAS RISER DIAGRAM <br /> NICOLE CAPLAN (949) 353 5134 nicole@e4designxom P3.2 WATER RISER DIAGRAM <br /> P4.1 PLUMBING DETAILS <br /> P4.2 CO2 DETAIL <br /> GAS: P5.1 PLUMBING CALCULATIONS Sheet Number: <br /> P6.1 PLUMBING SPECIFICATIONS <br /> Hasib Habibi P7.1 GREASE RECLAMATION DETAILS <br /> Em: HlHG@pge.com <br /> Ph: 209.272.8615 <br /> P 1 ■ 0 <br /> J <br /> Q <br /> H <br /> H <br /> L <br /> m <br />