Laserfiche WebLink
II II <br /> II H <br /> II II <br /> OL OL- -1 n _ _ n W N co <br /> o <br /> w EA <br /> o ~ � <br /> II x f = <br /> W ,Cz <br /> ILW_ �h L3 cn o <br /> o 0 <br /> I I x <br /> =C? <br /> O <br /> II C/) -Nti <br /> cv <br /> O rn <br /> II II � <br /> 25 ❑ o 0 0 o II <br /> 5 ® II <br /> WH II <br /> Store: <br /> KKKK/ <br /> u o 0 0_0 <br /> - C C C KETTLEMAN & L. SACRMENTO <br /> 0 00 00 00 HMV <br /> ❑� ❑❑ - — LODI CA 95242 <br /> pppppp 2442 o 0 0 0 0 35 O <br /> HHH00 ° ° ° 0000 ° ❑ s III L ❑ J J J <br /> 00000000uu 0 0 0 0 _ I <br /> Restaurant #RC576 <br /> uuuuuuuuuu ° ° ° > we-1 _ <br /> ° ° ° ° ° ° 2 P4E-HV-M SCHEME A <br /> " K M ° ° ° ° ° ° L 1 =�` <br /> 00 00 �� \ ` ❑ Professional of Record: NAME <br /> 00 00 ° ° ° ° ° ° HS-2 - -UR 36 - - - - - - - - HS-2 MV = \\\ <br /> �l A` <br /> uuuuuu ' <br /> 00000000 2442 ° ° ° ° ° ° Mv0 ❑ II v �� r7 - - - - - - - � <br /> uuuuuuuuuu ° ° ° ° ° ° 3-COMP — I <br /> uuuuuuuuuu W ° ° ° ° ° = 2 — — 2 ---- 1 <br /> 1 o 1-1/2'cw — <br /> Ll 11 <br /> WC-2 <br /> " oo WC-2 ❑ / 11 / 1 <br /> 1 111III 1 RoE31SON <br /> 0 1 2"CW i o0 00 1 3/4,>FW-q=oo _ - - - - - i _ - <br /> 2 7 / _ _ 00 00 - - - - II 11 I I <br /> _ ENGINEERING, <br /> 0 0 <br /> o0 <br /> — — =I%,- <br /> - — — — — — Ll \ LYNNWOOD,WA 98036 <br /> CO2 <br /> 3/4"H WR 3/4"H WR - - - - - - - - - - - - 206-364-3343 TEL <br /> -mad _ b HS-1 11 P ❑ <br /> 26 - - - - - 30 - - - - - 20 - - - - - _ T MV 3/4"FW- / \ �� °-��- <br /> _ _ I REI# 424-1551 <br /> I I I <br /> T 3 111 <br /> 31 COOKING OI 0 i <br /> COLLECTION v ❑ HMV1 m L \ / - <br /> SYSTEM N _ <br /> 1I <br /> ® ® ❑� <br /> 9 3 <br /> ����� 243 ullu6 2 3 — ®� ❑ <br /> —— uuuuuuuu uuuuUuuu — o o c — QR()FESS/ON <br /> uuuuuuuuuu uuu�Ouo - o o 20 1 _ _ r 0 <br /> q <br /> 2436 442 I 000 000 000000 — — D R �� <br /> —— PRE-WASHING I - <br /> ICE MACHINE <br /> b �I c > MNK ❑ <br /> � z <br /> 7 736 0 11 � co m I i \�- � 16 <br /> i uuuuu 24 Q I w o. M-2871 <br /> HS-1 uiii ui I HS-1 L -_ � L <br /> 3 7 29 00000000001\ MV ❑ L — 111 — — I L Mv— `� 32 L — — — — — — — <br /> - - - I-\/ 4 <br /> s <br /> -/ - - - - �_ <br /> - - _ <br /> ❑ o � / 1-1/4j"HW1 1 � 4 - - �aAvo - - - - - - � �gTFOF <br /> WATER SOFTENER/ GWH - - - - - - <br /> - - <br /> Ga- - <br /> / a 2"CW i"CW - - - - 3/4"CW - - - <br /> BRINE TANK _ I <br /> BOOSTER PUMP/ � - - - - - - i � J <br /> EXP. TANK ® _ - - - - - - ® ® \ / - � <br /> C o 1-1/4"HW \ / \ 3/4"CW 12�21�20 <br /> SET BOOSTER I I 3/4"FW—A— -_ �.. - - - - - - 3/4„F - /_- - - - 8 _ - - -1 r1 • <br /> W A 1 <br /> PUMP TO 79 PSI 34 � U 77 <br /> C u — III - - - �—� - - - - - - - -I - - - - - - - � - - r <br /> IIII Prototype : P4E-HV 2020 -2.0 RELEASE <br /> 1 24 21 ❑II BOWL FAUCET // Q — — — — �n o� — ❑� T11E] <br /> _ __ �] 1 �I/ III oo° II Prototype Issue Date: 7.14.2020 <br /> o � ' <br /> D /� iv 13 ❑ ❑ T _ —� _ _ ,� 1 x/1 11 ❑ ❑❑ III .> <br /> '51W Design Bulletin Updates: <br /> 04 <br /> 4-4/_+ <br /> 1I ❑ — ❑ — �❑ — — _ _ _ _ _ _ _ _ _ _ _ _ - - — O <br /> 5 WH — r/ 15 a — o 0 3660 _ <br /> ❑— — — /4"CW Date Issued: Bulletin Number: <br /> -- <br /> -- -- <br /> 22 SODA DISPENSER IRPZ, RPZ, TYP 1ST BLDG. SUBMITTAL <br /> TYP 7 6 7 SODA DISPENSER❑ <br /> PLUMBING FLOOR PLAN DI <br /> SCALE: 1/4"= V-0” <br /> 21 KEYNOTES 31 GENERAL NOTES <br /> REVISIONS: <br /> ❑ 2" CW RISER INTO BUILDING ATTIC SPACE, SHUT-OFF VALVE IN ACCESSIBLE LOCATION. 1 5 3/4" H/CW BRANCH CONNECTIONS TO SERVE WASH AREA FAUCET (WF) WITH INTEGRAL 26 FLUSH MOUNTED BULK CO2 REMOTE FILL. REMOTE CO2 FILL LOCATION SHALL BE 1. PLUMBING CONTRACTOR SHALL PROVIDE ALL FILTERED WATER PIPING AND CONNECTIONS AS REQUIRED TO MAINTAIN COMPLETION OF KITCHEN 12.22.2020 1st Building Submittal <br /> VACUUM BREAKER. VERIFIED AND APPROVED BY PROJECT MANAGER. EQUIPMENT INSTALLATION. RE: FOOD SERVICE DRAWINGS FOR FILTERED WATER PIPING AND REQUIREMENTS. 1 <br /> ❑2 1-1/2" CW DOWN TO WATER CLOSET. PROVIDE PDI UNIT SIZE B WATER HAMMER <br /> ARRESTOR. 1 4 R/4" CW E OWN RO : WATER <br /> FILTER. RE:FOR WATER FILTER SERVICE <br /> DRAWINGS <br /> N E FILTERED ROUGH-IN <br /> WATER PIPING 27 PROVIDE CO2 MONITORING SYSTEM, CO2 METER LOGICO2 MK9. SEE DETAIL 2/P4.2. 2. PLUMBING CONTRACTOR SHALL COORDINATE FIXTURE LOCATIONS WITH EQUIPMENT DRAWINGS AND MILLWORK. 2 <br /> SET ALARM TO ACTIVATE AT 5,000 PARTS PER MILLION. ALARM TO INITIATE 3 <br /> 0 1/2" H/CW DOWN TO SERVE HAND SINK. RE: FOOD SERVICE DRAWINGS FOR ROUGH-IN AS SHOWN ON WATER FILTER DETAIL. STROBE AND AUDIBLE ALARM WITHIN THE ROOM. CM TO VERIFY FINAL LOCATION. 3. CROSS LINKED POLYETHYLENE (PEX) PIPING MAY BE USED FOR DOMESTIC WATER PIPING IN WALLS AND ATTIC SPACES WHERE ALLOWED BY LOCAL <br /> REQUIREMENTS.PROVIDE POINT-OF-USE MIXING VALVE (MV) TO SERVE HAND SINK AS CODES. CONTRACTOR SHALL VERIFY ACCEPTANCE OF ITS USE WITH LOCAL INSPECTION OFFICE AND CODE AUTHORITY BEFORE INSTALLING. 4 <br /> LISTED BY SPECIFICATIONS. 15 1/2" FILTERED WATER A DOWN TO SERVE POT/ BOWL FILL FAUCET. 28 NOTIFICATION SYSTEM/DEVICE. CM TO VERIFY FINAL LOCATION. FLUSHING, TAGGING AND REPORTING REQUIRED PER PEX PIPING PER CPC SECTION 604.1.2. 5 <br /> 0 1/2" H/CW DOWN TO SERVE LAVATORY (HS-2). PROVIDE POINT-OF-USE 16 1/2" FILTERED WATER B DOWN TO ICE MACHINE(S). COORDINATE EXACT LOCATION WITH 29 CO2 SUPPLY LINE DOWN TO CARBONATORS. 4. REDUCED PRESSURE ZONE BACKFLOW PREVENTERS (RPZ) SHALL HAVE HAVE THEIR RELIEF PORT DISCHARGE ROUTED TO THE NEAREST 6 <br /> MIXING VALVE (MV) TO SERVE LAVATORY AS LISTED BY SPECIFICATIONS. ARCHITECT/OWNER PRIOR TO ROUGH-IN. CODE-APPROVED FIXTURE. PROVIDE AIR GAP FITTING AT RELIEF PORT CONNECTION. 7 <br /> ❑ 3/4" CW DOWN TO SERVE WALL HYDRANT. 0 <br /> 17 1/2" FILTERED WATER A DOWN TO 1/2" RPZ BACKFLOW30 PREVENTER BELOW COUNTER, ALL PIPING MARKED AND LABELED, EVERY 20FT. EVERY CHANGE OF DIRECTION. 5. REFER TO CIVIL DRAWINGS FOR FINISHED FLOOR ELEVATION. 8 <br /> CONNECT TO SODA DISPENSER. COORDINATE EXACT LOCATION WITH ARCHITECT/OWNER 31 VENT LINE TO FILL BOX. 6. REFER TO FOOD SERVICE FLOOR PLANS AND ELEVATIONS FOR ALL ROUGH-IN REQUIREMENTS. <br /> ❑ 3/4" H/CW UNDERGROUND TO SERVE DUMPSTER POST HYDRANT WITH INTEGRAL PRIOR TO ROUGH-IN. RE: FOOD SERVICE DRAWINGS FOR ROUGH-IN REQUIREMENTS. <br /> VACUUM BREAKER. PROVIDE CHECK VALVE AT BRANCH CONNECTION. RE: 32 3/4" CW/1-1/4"HW DOWN WALL. PROVIDE SHUT-OFF VALVE IN ACCESSIBLE <br /> ARCHITECTURAL FOR DUMPSTER ENCLOSURE DETAIL. VERIFY EXACT LOCATION WITH 0 1/2" FILTERED WATER B DOWN TO SERVE ICED TEA BREWERS. COORDINATE EXACT LOCATION PRIOR TO ROUTE UNDERGROUND AND BRANCH 1/2" H/CW TO SERVE 7. INSTALL PLUMBING FIXTURES AND EQUIPMENT TO MANUFACTURER'S SPECIFICATIONS. <br /> ARCHITECT/OWNER PRIOR TO ROUGH-IN. LOCATION WITH ARCHITECT/OWNER PRIOR TO ROUGH-IN. RE: FOOD SERVICE DRAWINGS HAND SINKS. RE: FOOD SERVICE DRAWINGS FOR ROUGH-IN REQUIREMENTS. Sheet Title: <br /> FOR ROUGH-IN REQUIREMENTS. PROVIDE POINT-OF-USE MIXING VALVE (MV) TO SERVE HAND SINK AS LISTED BY 8. REFER TO CIVIL AND E4 UTILITY DRAWINGS FOR POINT OF CONNECTION AND ROUTING TO MAIN LINES. WATER PLUMBING <br /> 0 1/2" FILTERED WATER A DOWN TO SERVE CARBONATOR. RE:FOOD SERVICE DRAWINGS SPECIFICATIONS. <br /> FOR ROUGH-IN REQUIREMENTS. PROVIDE 1/2" RPZ BACKFLOW PREVENTER BEFORE 9 TO 2" MANFOLDEWITH SERVINGNEUMATIC HOODED QUIPMEENT,DRE:U1P2.A1TIC FORAS SHUT-OFF CONTINUATTIONF33 SEE 2P3..1 1/2" H CW TO SERVE HAND SINK AT HALF WALL. CONTINUE UNDERGROUND 1" HW PLAN <br /> ROM ROOF <br /> DROP. FOR KITCHEN EQUIPMENT BATTERY. ROUTE BACK TO ABOVE CEILING HW ROUTING. RE: FOOD SERVICE DRAWINGS FOR <br /> 1-1/4"H/CW AND 3/4" HWR DOWN TO SERVE WATER HEATER, RE: 2P5.1 FOR DETAIL. ROUGH-IN REQUIREMENTS. PROVIDE POINT-OF-USE MIXING VALVE (MV) TO SERVE <br /> ROUTE CONCENTRIC VENT FROM WATER HEATER UP THROUGH ROOF WITH TERMINAL 20 1/2" FILTERED WATER A DOWN TO SERVE MARINADE STATION FAUCET. HAND SINK AS LISTED BY SPECIFICATIONS. Date: 12.07.2020 <br /> CUT TO LENGTH AS PER MANUFACTURER'S REQUIREMENTS. ROUTE CLEAR TUBING FROM <br /> CONDENSATE COLLAR (AT TOP OF HEATER) TO FLOOR DRAIN BELOW. SEE PLUMBING 21 1-1/2" GAS LINE FROM ROOF, RE: 1P2.1 34 ROUTE 2" CW TO BOOSTER PUMP WITH 10 GALLONS EXPANSION TANK. PROVIDE Project Number: RAC19048.0 <br /> SPECIFICATIONS. CHECK VALVE PRIOR TO BOOSTER PUMP. INSTALL PER MANUFACTURER'S <br /> 22 RE: CIVIL DRAWINGS FOR SITE UTILITY DRAWING. SPECIFICATION WITH BY-PASS VALVE AND SHUT-OFF VALVES. RE:3/P6.1 FOR <br /> RPZ INSTALLED IN LINE. SEE KEYNOTES FOR MOUNTING LOCATIONS. Drawn By: _ <br /> 09 23 4" GAS UP TO ROOF, RE: 1P2.1 FOR CONTINUATION. 1" GAS TO GAS HEATERS AT DRIVE MODEL.. <br /> E <br /> THRU STATION. FIELD TO DETERMINE FINAL CAP LOCATION PRIOR TO BID AND <br /> 10 1/2" H/CW DOWN TO SERVE SINK FAUCET AND PRE-RINSE FAUCET. INSTALLATION, RE: CIVIL DRAWINGS FOR SITE GAS ROUTING. GAS METER AND REGULATOR 0 3/4" H/CW DOWN TO SERVE CHEMICAL DISPENSING RACK WITH SHUTOFF VALVES <br /> (IF REQUIRED SHALL BE PROVIDED AT CONTRACTOR'S EXPENSE. (FULL PART BALL VALVES). COORDINATE WITH ARCHITECT/OWNER FOR EXACT <br /> 11 3/4" H/CW DOWN TO SERVE BREADING WASH-UP STATION. 3 SINKS. PROVIDE MIXING LOCATION PRIOR TO ROUGH-IN. RE; FOOD SERVICE DRAWINGS FOR ROUGH-IN <br /> VALVE FOR HANDSINKS. 2" CW DOWN TO/UP FROM WATER SOFTENER. PROVIDE 2" VALVED CW STUB-OUTS AND REQUIREMENTS. PROVIDE 3/4" STAINLESS STEEL RPZ BACKFLOW PREVENTER IN Sheet Number: <br /> 24 <br /> VALVED 2" BYPASS LINE FOR CONNECTIONS TO WATER SOFTENER. RE: FOOD SERVICE EACH LINE. <br /> 1" CW UP TO RHY, RE: 1P2.1. PIPE DRAIN CONNECTION (1/8"NPT) TO NEAREST VENT DRAWINGS FOR ROUGH-IN ELEVATIONS. PROVIDE ALL NECESSARY FITTINGS/COMPONENTS <br /> 2 S <br /> RISER. TO INSTALL EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS. 36 1" CW DOWN TO SERVE URINAL <br /> 25 RE: CIVIL DRAWINGS FOR SITE GAS ROUTING. 37 1/2" CW TO OUTDOOR HANDSINK FIELD TO DETERMINE FINAL CAP LOCATION PRIOR <br /> 0 <br /> TO BID AND INSTALLATION. P • Q <br /> m <br />