Laserfiche WebLink
INSTALLATION WITHOUT REPLACEMENT PANEL REPLACEMENT PANEL PART NUMBERS <br /> 1. Locate area for installation of the unit.The unit should be installed as BRAND CAPACITIES PART NUMBER <br /> close to wall as possible. Mark wall as shown in Figure 4 and cut a sueuaeAN8 GALLON 6276APW(Polar white) <br /> 3.750"Diameter hole for vent installation. On mesa or yoder type side <br /> walls,it may be required to flatten area where vent is to be installed to SUBURBAN 10.12,t6 GALLONS 6277APW(Polar white) <br /> ensure seal around vent assembly. ATWOOD 6 GALLON 521147(Polar White) <br /> 2. Place unit on floor(verify vent cap lines up with exhaust tube and ATWOOD 10 GALLON 521150(Polar White) <br /> combustion air opening in unit). - <br /> a. Drain lines must be connected to the system and condensation NUMBERVENT CAP T VENT CAP LENGTH "X"MAX DIMENSION <br /> SEE FIGURE 7A <br /> drains on the On Demand water heater and ran to the outside 260616 0-1 inches 1.171 inch <br /> of the RV. Drain Lines should be as short as possible and <br /> must maintain a drop of 1/4"per foot from unit. See Figure 5. 260617 1-2 inches 2.171 inch <br /> 3. Install vent assembly. See Figure 6. 260618 2-3 inches 3.171 inch <br /> a. Vent cap must be ordered separately. See TABLE 1 for 260638 5-6 inches 6.171 inch <br /> vent sizes and part numbers. A minimum overlap of 1.25" is TABLE 1 <br /> required on exhaust. <br /> b. Apply a bead of silicone around the vent cap as shown in Figure 6. <br /> c. Install vent cap as shown in Figure 6 with screws. Ensure MAKING ELECTRICAL CONNECTIONS <br /> assembly is sealed to outside wall to prevent leaks. 12 VOLTS D.C. (SEE FIGURE 11) <br /> 4. Screw the front of the unit to the Floor using the two brackets as shown in A. The electrical connections must be made in accordance with <br /> Figure 5. local codes and regulations. In the absence of local codes and <br /> 5. Make electrical, drain, water and gas connections following regulations, refer to the latest edition of the National Electrical <br /> instructions contained in this manual or the manual supplied with Code NFPA 70. <br /> the Suburban NAUTILUS(IW60)On Demand Water Heater. In Canada,the electrical installation should conform with CSA standard <br /> 2240.6.2-08/C22.2 No. 148-08 Electrical Requirements for <br /> INSTALLATION USING REPLACEMENT PANEL Recreational Vehicles. <br /> A replacement panel is used when replacing Suburban 6, 10, 12, and B. Make the 12 Volt D.C. electrical connections following the wiring <br /> 16 gallon tank units and Atwood Style 6 and 10 gallon tank units. diagram illustrated in Figure 11. <br /> 1. On mesa or yoder type sidewalls, flatten the wall area around the If the power supply is to be from a converter, we recommend that the <br /> opening. converter system be wired in parallel with the battery. This will serve <br /> 2. Apply a continuous line of suitable caulk on the RV wall around two purposes: <br /> all four sides of the opening and around back side of replacement 1. Provide a constant voltage supply <br /> panel frame as shown in Figure 8.This caulk is required to create 2. Filter any A.C. spikes or volt surges <br /> water tight seal of the frame to the RV wall. We recommend insulated terminals be used forall electrical connections. <br /> 3. Center and insert caulked replacement panel frame into opening. <br /> Push frame firmly against RV wall over caulking previously applied INSTALLATION OF SWITCH AND LIGHT ASSEMBLY <br /> in step 2. Secure frame with the eight(8)supplied screws into RV (SEE FIGURE 12) <br /> wall as shown in Figure 8. 1. ON/OFF switch is wired as shown in wiring diagram. See Figure 11. <br /> 4. Locate the water heater cabinet approximately even with the inside 2. There is a connection for a lockout light (If used,this light will come <br /> RV wall. See Figure 7B. If securing the unit to the floor using on if the unit goes into lockout. Water must be turned off and back on <br /> the FRONT mounting brackets, proceed to STEP 5. To mount the to re-cycle the unit.) <br /> water heater using the REAR mounting method, remove the two 3. Connect ORANGE wire to LED lamp(+)and BLUE wire to LED lamp(-). <br /> mounting brackets from the front of the unit and secure them to the <br /> threaded holes at the rear of the unit. Screw the rear of the unit to INSTALLATION OF OPTIONAL ON DEMAND <br /> the floor using the two brackets. See Figure 7B. CONTROL CENTER (SEE FIGURE 13) <br /> 5. Using the gasket supplied with the kit, apply the gasket beginning 1. On Demand Control Center is wired as shown in wiring diagram. See <br /> at the center bottom of the replacement panel frame. Adhere the Figure 11. <br /> adhesive side of the gasket to the replacement panel frame and 2. Locate the On Demand Control Center on a wall surface adjacent <br /> install the gasket all the way around the frame. Ensure the ends of to the On Demand water heater. <br /> the gasket meet at the center bottom of the access panel frame. 3. Remove back cover from control center by depressing latch at bottom. <br /> 6. Attach the replacement panel to the frame as shown in Figure 8 4. Remove center knockout from back cover. Drill hole for wiring from <br /> using the five(5)screws provided. control center. See Figure 14. <br /> 7. Vent cap must be ordered separately. See Table 1 for vent sizes and 5. Mount back cover to the wall. <br /> part numbers.There must be a minimum of 1.25" (31.8mm)overlap S. Route wiring through back cover and hole into wall. <br /> of vent assembly tube over exhaust tube on the On Demand Water 7. Connect the two white wires from the On Demand Control Center <br /> Heater and the replacement panel must compress the replacement to the two white wires from the On Demand water heater. See <br /> panel gasket. See Figure 7A. Figure 11. <br /> a. Apply a bead of silicone around the vent cap as shown in TheoptionalOn Demand Control Center displays the water temperature <br /> Figure 8. and also allows outlet water temperature to be adjusted (130°F <br /> b. Install vent cap as shown in Figure 8 with four (4) screws. maximum). <br /> Ensure assembly is sealed to outside wall to prevent leaks. ON DEMAND CONTROL CENTER PART NUMBER <br /> 8. Screw the front of the unit to the floor using the two brackets as shown <br /> in Figure 5. BLACK 161253 <br /> 9. Apply silicone caulk around the beveled edges of the replacement WHITE 161252 <br /> panel as shown in Figure 8. Do not caulk the bottom of the <br /> replacement panel. <br /> 10. Make electrical drain, water and gas connections following <br /> instructions contained in this manual or the manual supplied with <br /> the Suburban NAUTILUS(IW60)On Demand Water Heater. <br /> 4 <br />