TO TURN OFF THE ON DEMAND WATER HEATER ON DEMAND HEATER COMES ON AND RAPIDLY CYCLES ON AND <br /> 1. Turn switch to "OFF' position for units using the Switch and Light OFF: <br /> Assembly. 1. Water flaw is too low. Increase flow at faucet. <br /> 2. For units using the optional On Demand Control Center, press the 2. Clean all shower heads, faucet aerators or water strainers as <br /> power button once. required and remove any flow restrictions to ensure the minimum <br /> 3. Turn off electrical power to the appliance. 0.5 GPM of water flow. <br /> 3. Verify the water pump is functioning properly. <br /> 4. Turn off gas supply. 4. Bleed air out of plumbing lines by opening all water faucets. <br /> 5. If vehicle is to be stored or heater is going to be turned off while 5. If the On Demand water heater cycles as the pump cycles, an <br /> subject to freezing temperature, drain water heater. (See"Draining accumulator tank is needed in the water system. If accumulator <br /> and Storage Instructions.") tank is already installed, check for water inside the tank and drain <br /> tank until only air is present. <br /> SEQUENCE OF OPERATION 6. Water source pressure fluctuates too low causing loss of flow. <br /> The following Sequence of Operation will be the same when using Check the incoming water source for a minimum of 30 psi, <br /> either the ON/OFF SWITCH or the optional On Demand Control Center. 7 If using the standard ON/OFF Switch and Light, reset dip switches <br /> 1. Turning on a hot water faucet activates the On Demand Water back to factory setting of 120°F(see figure 12). If using the ON <br /> Heater. DEMAND CONTROL CENTER, decrease the set temperature <br /> 2. The flow sensor senses the flow of water. back to 120°F. <br /> 3. The pressure switch proves that the combustion air fan is working, WATER TEMPERATURE IS TOO LOW WITH LOWER WATER FLOW: <br /> 4. The combustion chamber is then purged of any remaining raw gas. 1. Waterflow .is too low. Increase flow at faucet to ensure the minimum <br /> 5. The burner will ignite and the electrode/Flame probe assembly 0.5 GPM of water flow. <br /> proves the flame. <br /> a. The approximate time from turning on the faucet to ignition is WATER TEMPERATURE IS TOO HIGH OR NO TEMPERATURE <br /> 7 seconds. After the initial lighting sequence and the water CONTROL: <br /> heater is maintaining temperature,the ignition cycle is reduced 1. For units with the Standard Switch and Light assembly, adjust the <br /> to approximately 5 seconds. dip switches to the desired temperature. Refer to OPERATING <br /> b. Burners will stay ON until the water flow is shut off. INSTRUCTIONS WITH SWITCH AND LIGHT ASSEMBLY and <br /> 6. The flow of hot water at the SET point begins approximately 3 see Figure 12 for information on setting dip switches to desired <br /> seconds after ignition but will not reach the faucet until the hot water temperature setting. <br /> lines leading to the faucet are cleared of any remaining water. This 2. For units using the optional On Demand Control Center, press <br /> time is determined by the length of the hot water line. the UP or DOWN arrows on the On Demand Control Center to <br /> 7. When the hot water faucet istumedOFF,thewater heater shuts down increase the SET water temperature in single increments. Refer <br /> and will remain at a read state until FF,th err is called fora air. to OPERATING INSTRUCTIONS WITH OPTIONAL ON DEMAND <br /> y g CONTROL CENTER and see Figure 13. <br /> NOTE: Blower motor will operate for approximately 20 seconds after <br /> the hot water faucet is turned OFF. LOW TEMPERATURE RISE AND EXCESSIVE WATER FLOW <br /> 8. If the ON/OFF SWITCH or On Demand Control Center are left in REQUIRED TO TRIGGER THE ON DEMAND WATER HEATER: <br /> the ON position, no further action is required by the user. NOTE: If you find that your water heater requires excessive flow to <br /> 9. If the water heater fails to light for any reason, a second Trial activate it (over 0.5 GPM), it is possible that you have COLD water <br /> For Ignition(TFI) will automatically begin. If the second Trial For bleeding into the HOT water side of your water system. <br /> Ignition(TFI) fails, the water heater will automatically begin a third 1. Verify that valves and faucets are closed when not in use. Check <br /> Trial For Ignition(TFI). If the third Trial For Ignition(TFI) fails, the the shower head for an ON/OFF button/lever and ensure it is in <br /> water heater will go into a lock out mode and will not try to light the the OFF position to prevent cold water from bleeding into the hot <br /> burner again.To reset: water system. This can keep the On Demand water heater from <br /> a. Using ON/OFF SWITCH:Turn Switch OFF then back ON. functioning correctly. <br /> b. Using the On Demand Control Center.Tum faucet OFF,then back 2. If your RV is equipped with a bypass valve at the water plumbing <br /> connection, make sure it is in the OFF position. An open valve can <br /> on. allow water to bypass water heater causing a failure to ignite. <br /> NOTE: The NAUTILUS (IW60) On Demand WATER HEATER has <br /> an energy mode circuit that will shut down operation if operating NO IGNITION: <br /> continuously for three(3)hours. To reset,follow the instruction in STEP If the burner will not come on,the following items should also be checked <br /> 9 A or B above. before calling a service technician: <br /> NOTE: Air in the gas line after changing propane tanks is the main A. Switch turned off. <br /> reason for not lighting the burner. A simple method to remove air from B. 12 VDC power is ON, <br /> the gas line is to ignite a burner on the installed cooking appliance C. Gas supply to heater is empty or turned off. <br /> inside your RV. D. Water turned on and faucet open. <br /> E. Check manual reset on ECO switch. Refer to DETAIL"A" in <br /> Figure 9. <br /> OPERATIONAL TROUBLESHOOTING If burner fails to light, call a Suburban service center or a local RV <br /> service agency. <br /> NOTE: There must be a demand of at least 0.5 GPM for the burner to <br /> operate and allow water flow. This will continue until the water flow is <br /> turned OFF and the system goes dormant. <br /> NO WATER FLOWS FROM FAUCET WHEN TURNED ON: <br /> 1. Be sure water supply is turned ON and there are no water <br /> restrictions. <br /> 2. Ensure BYPASS SYSTEM (if installed) is properly aligned for <br /> operation. <br /> BURNER TURNS ON,TEMPERATURE FLUCTUATES ERRATICALLY: <br /> 1. This issue can be caused by restriction in the shower heads,faucet <br /> aerators or water strainers. <br /> 2. Clean as required and remove any flow restrictions. <br /> 6 <br />