TILLIE LEWIS
>
1477
>
2800 - Aboveground Petroleum Storage Program
>
PR0523160
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2022 8:53:28 AM
Creation date
3/7/2022 10:35:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0523160
PE
2832
FACILITY_ID
FA0010602
FACILITY_NAME
WILLIAMS TANK LINES
STREET_NUMBER
1477
STREET_NAME
TILLIE LEWIS
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16336003
CURRENT_STATUS
01
SITE_LOCATION
1477 TILLIE LEWIS DR
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Compliance Standard <br /> Design Construction of tank:_Single wall AST ®Yes FZ71 lYes F-] No <br /> (CFC 21.5.4.1.1) <br /> Design of Supports: Steel Yes F� No <br /> (NFPA 30)(CFC 340W 2.7.F) <br /> Electrical wiring of fuel pump--ULApproved— FX-] Yes F-] No <br /> (CFC 3403.1) <br /> Piping System Components:—Steel— 0 Yes ❑ No <br /> (CFC 3403.6.2) <br /> Tank Normal venting:_2" 14'—Abovegrade— ® Yes [—] No <br /> (CFC 3404.2.7.3) <br /> Emergency Venting system:_Emergency vents_ Q Yes ❑ No <br /> (CFC 3404.2.7.4) <br /> Tank Labelling:_NFPA 704_ FX1 YesM No <br /> (CFC 3404.2.3.1 -3404.2.3.4) <br /> Overfill protection:—Over fill by driver observation— ® Yes ❑ No <br /> (CFC 3404.2.9.6) <br /> Liquid Transfer of fluids:—Positive Displacement— [—X] Yes ❑ No <br /> (CFC 3405.2) <br /> Spill Control: _Concrete Pad [-X] Yes ❑ No <br /> (CFC 3405.2) <br /> Protection from Vehicles:-Concrete wall- ®Yes ❑ No <br /> (CFC 5704.2.9.7.4 & 5704.9.3 <br /> Grounding & Bonding of Electrical system:_No ❑ Yes ® No <br /> (NFPA 77-3.1.2 & 29 CFR 1910.106(e)(6)(Y) <br /> Tank Anchorage: _0 Anchors- ❑Yes X No <br /> (CFC 5704.2.8.5) <br /> Tank is suitable for continued use—Yes— FX�Yes F-] No <br /> (SPOO I 10) <br /> Gary Reeves <br /> SP001 Level If#11111 <br /> Gary Reeves, LLC <br /> 4649 Monarch Court <br /> Turlock, CA 95382 <br /> gaty@gatyreevesllc.org <br /> 209 661 6611 <br />
The URL can be used to link to this page
Your browser does not support the video tag.