My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
5100
>
2800 - Aboveground Petroleum Storage Program
>
PR0526956
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:46:03 PM
Creation date
3/11/2022 11:05:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0526956
PE
2832
FACILITY_ID
FA0010619
FACILITY_NAME
FRANK C ALEGRE TRUCKING INC
STREET_NUMBER
5100
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242-9529
APN
05516061
CURRENT_STATUS
01
SITE_LOCATION
5100 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; <br /> SAN x�JOAQU � Environmental Health Department <br /> � <br /> c0uNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FRANK C ALEGRE TRUCKING INC 5100 W HWY 12 , LODI March 10, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 706 CFR 112.8(c)(2)Failed to provide and maintain adequate secondary containment for bulk storage tanks. <br /> OBSERVATION: The facility failed to provide and maintain secondary containment for bulk storage tank <br /> installations sufficient to hold the capacity of the largest container, including adequate freeboard for precipitation. <br /> One diesel storage tank,which appeared to be single walled (estimated to be able to store 8000 gallons)was <br /> found on site without adequate secondary containment.This tank was located adjacent to the onsite bulk storage <br /> diesel and gasoline tanks. Mr. Henry Rotor indicated that this tank is used for overflow fuel deliveries and has <br /> been brought to the site sometime in the last 1-2 years. <br /> REGULATION GUIDANCE: (c)(2)Construct all bulk storage tank installations(except mobile refuelers and other <br /> non-transportation-related tank trucks)so that you provide a secondary means of containment for the entire <br /> capacity of the largest single container and sufficient freeboard to contain precipitation.You must ensure that diked <br /> areas are sufficiently impervious to contain discharged oil. Dikes, containment curbs, and pits are commonly <br /> employed for this purpose.You may also use an alternative system consisting of a drainage trench enclosure that <br /> must be arranged so that any discharge will terminate and be safely confined in a facility catchment basin or <br /> holding pond. <br /> CORRECTIVE ACTION: Immediately provide and maintain adequate secondary containment for the following bulk <br /> storage tank: overflow diesel tank located adjacent(but outsite of the secondary containment)to the bulk diesel <br /> and gasoline tanks. Submit proof of correction to the EHD. <br /> This is a repeat violation, Class Il. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 4/10/2022. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> The following was provided during this inspection: Schedule of free CUPA classes. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: March 10, 2022 Inspector: Inspector Phone: <br /> Printed Name and Title: ELENA MANZO, Program Coordinator (209)953-7699 <br /> Henry Rotor, henry@alegretrucking.com <br /> FA0010619 PR0526956 SCO01 03/10/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 9 of 9 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.