My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
17720
>
2200 - Hazardous Waste Program
>
PR0523369
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2022 8:26:24 AM
Creation date
3/14/2022 11:02:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0523369
PE
2228
FACILITY_ID
FA0004518
FACILITY_NAME
NORTH COUNTY LANDFILL
STREET_NUMBER
17720
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06512004
CURRENT_STATUS
01
SITE_LOCATION
17720 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN ,dDAQ U I N Environmental Health Department <br /> C01-1 N T <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NORTH COUNTY LANDFILL 17720 E HARNEY LN, LODI February 24, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATION: The facility's hazardous waste tanks are not inspected at least once each operating day. <br /> REGULATION GUIDANCE: <br /> (a)The owner or operator shall inspect,where present, at least once each operating day: <br /> (1)overfill/spill control equipment(e.g.,waste-feed cutoff systems, bypass systems, and drainage systems)to <br /> ensure that it is in good working order; <br /> (2)the aboveground portions of the tank system, if any, to detect corrosion or releases of waste; <br /> (3)data gathered from monitoring equipment and leak-detection equipment, (e.g., pressure and temperature <br /> gauges, monitoring wells)to ensure that the tank system is being operated according to its design; <br /> (4)the construction materials and the area immediately surrounding the externally accessible portion of the tank <br /> system including secondary containment structures(e.g., dikes)to detect erosion or signs of releases of hazardous <br /> waste (e.g.,wet spots, dead vegetation); and <br /> (5)for uncovered tanks,the level of waste in the tank, to ensure compliance with section 66265.194(b)(3). <br /> (c)The owner or operator shall document in the operating record of the facility an inspection of those items in <br /> subsection (a)of this section. <br /> CORRECTIVE ACTION: Immediately start conducting and documenting complete daily hazardous waste tank <br /> inspections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> 512 CCR 66265.192(h) Failure to obtain a reassessment of a tank system within 5 years or as required. <br /> OBSERVATION: This facility has a hazardous waste tank which have not been assessed by a Professional <br /> Engineer within the past five years. The hazardous waste tank is: one 240 gallon tank storing used oil was <br /> observed in the maintenance shop. <br /> REGULATION GUIDANCE: <br /> The assessment specified in subsection (k)of this section shall be obtained prior to placing a new tank system in <br /> service and shall be kept on file at the facility.This assessment shall be reviewed and certified by an independent, <br /> qualified, professional engineer, registered in California, in accordance with section 66270.11(d), attesting that the <br /> tank system has sufficient structural integrity and is acceptable for the transferring, storing and treating of hazardous <br /> waste. The assessment shall be valid for a maximum period of five (5)years or the remaining service life of the tank <br /> system, as stated in the engineer's assessment,whichever is less. <br /> CORRECTIVE ACTION: Provide a corrective action statement and supporting documentation to the San Joaquin <br /> County Environmental Health Department(EHD)within 30 days. Provide a complete copy of the tank assessment <br /> document,when available. <br /> This is a Class II violation. <br /> FA0004518 PR0523369 SCO01 02/24/2022 <br /> EHD 22-02 Rev.12/06/2021 Page 6 of 10 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.