Laserfiche WebLink
5 6 <br />HOOD <br />DETAILS <br />K1.2CORDES VILLAGE PLAZARAJA SALEEM & SANDYA SALEEM, OWNERSTHuB TEA & CAKESREVISIONS DATE <br />DATEAPPROVAL <br />JOB: <br />DATE: <br />SHEET TITLE: <br />SHEET NO. <br />4/9/2020 <br />ADESNECILRCHITECTCW.NHOJ OWE <br />E <br />,JR. <br />NO. C-9199 <br />F <br />-1.N <br />ER <br />3 1 -2 1O <br />ETATS <br />C A L IF O RNIAJohnWCowee,Jr.MOUNTAIN HOUSE, CAwww.architectural-concepts.net <br />johncowee06@gmail.com <br />ARCHITECTURAL <br />INTERIORS PLANNING <br />509 RAMONA AVE. <br />ALBANY, CA 94706-1431 <br />T/F 510-525-9630 <br />CONCEPTS <br />ARCHITECTURE <br />REVISION 0 <br />STAMP:1140 SOUTH TRADITION STREETSK-MH-C1TENAANT IMPROVEMENT78" (6'-8") MIN. <br />84" (7"-0") MAX. <br />2'-0" <br />1'-0" <br />4'-0" <br />6"MIN. <br />2'-0" <br />48" MAX <br />42" MIN. <br />9'-0" <br />1'-10" <br />1'-0" <br />8'-8" <br />6"MIN. <br />3'-4" <br />(NFPA 96) <br />10" MINIMUM FROM ANY EXHAUST OR VENT <br />(POSITIONED TOWARD PREVAILING WIND) <br />10' OFF PROP. LINE <br />5' FROM PARAPET WALL <br />EXHAUST FAN BLOWER. <br />SPECIFY MODEL# PNU-150-50 <br />UL LISTED 762 FOR REMOVAL <br />OF HIGH TEMPERATURE GREASE <br />LADEN VAPORS, (OPTIONAL ITEM) <br />GREASE COLLECTOR <br />(INCLUDED WITH EXHAUST FAN) <br />VENTED EXHAUST FAN CURB <br />MODEL# EXCB-1 <br />LEVEL CURB BY G.C. <br />CAN'T STRIP & ROOFING UP TO CURB BY <br />ROOFING INSTALLER. <br />MINIMUM 1-HOUR FIRE RESISTANCE. <br />ONE HOUR FIRE RATED SHAFT <br />OR 3M UL APPROVED FIRE MASTER <br />DUCT WRAP BY G.C. SEE NOTE 4 <br />10" x 22" GREASE DUCT <br />16 GA GALVANIZED <br />ALL WELDED (BY OTHERS) <br />DRAFT STOP <br />(BY OTHERS) <br />3X VAPOR PROOF HOOD <br />LIGHT AND PORCELAIN <br />BASE, UL LISTED <br />(BULBS BY OTHERS) <br />S/S FILTER UL CLASSIFIED <br />3" AIR SPACE NOW INSULATED <br />S/S WALL FLASHING <br />OVER 1-HOUR FIRE <br />RESISTANCE WALL & <br />INSULATED 1" MINERAL BAT <br />5'-0" <br />TO CENTER <br />PERFORATED CEILING <br />DIFFUSERS SEE NOTE 6 (BY <br />OTHERS) <br />OPTIONAL CEILING CLOSURE PANEL <br />IF LESS THAN 12" CLEARANCE TO <br />CEILING (RIVET PANEL TO HANGER <br />CHANNEL) <br />REMOVABLE GREASE COLLECTOR <br />PITCH GUTTER (UBC 508.3) <br />COOKING SURFACE <br />(UBC 508.6) <br />(12" FOR BROILERS) <br />BOTH SIDES <br />ENCLOSURE 18 GA. S/S <br />THREADED HANGER <br />(BY OTHER) <br />FLEX DUCT <br />(BY OTHERS)FINISH CEILING LINE <br />GALVANIZED DUCT (BY <br />OTHERS) <br />CAN'T STRIP & ROOFING UP TO CURB BY <br />ROOFING INSTALLER <br />LEVEL CURB BY G.C. <br />SUPPLY FAN CURB MODEL# SPCB-1 <br />EVAP FAN CURB MODEL# ECCB-2 <br />(OPTIONAL ITEMS) <br />EVAPORATIVE COOLER MODEL# ED460-1/2 <br />UL LISTED 356J <br />MAKE-UP AIR PLENUM DIST. BOX (BY <br />OTHERS) <br />S/S HOOD UL-54-108-M, TYPE 1 <br />18 GUAGE CONST (UBC 508.2) <br />NSF CONSTRUCTION UL LISTED <br />VENTILATION HOLESROOF LINE <br />COOKING SURFACE <br />S/S WALL FLASHING <br />FACTORY RECOMMENDS 12" <br />OVERHANG ON CHAR <br />BROILERS LOCATED AT OPEN <br />END OF HOOD <br />AS SHOWN AS SHOWN <br />COOKING <br />EQUIPMENT <br />(BY OTHERS) <br />PARTIAL ROOF PLAN- SUITE 1158 1/4" = 1'-0"8 <br />19 <br />20 16 12 <br />1158 MECHANICAL SUPPLY <br />- SEE HVAC DRAWINGS <br />1158 HOOD SUPPLY - SEE <br />KITCHEN DRAWING K1.1 & <br />19/K1.2 1158 HOOD EXHAUST - <br />SEE KITCHEN DRAWING <br />K1.1 & 19/K1.2 <br />12X12 EXHAUST DUCT TO <br />EXHAUST HOOD. RUN IN <br />ATTIC SPACE <br />12X12 SUPPLY DUCT THRU <br />KITCHEN CEILING. RUN IN <br />ATTIC SPACE