Laserfiche WebLink
REF.REF.PLUMBING SCHEDULEITEM#EQUIPMENT DESCRIPTIONMANUFACTURERHOTWATERCOLDWATERDIRECTDRAININDIRECTDRAINVENTGASBTU'SMODELREMARKSHSHAND SINKELKAY1/2" 1/2"1 1/2" 1 1/2"EHS-18-SDXMPMOP SINKEXISTING 1/2" 1/2"1" 1 1/2"BY OWNER3 COMP SKCUSTOM 3-COMP SINKCUSTOM(2) 1/2" (2) 1/2" (3) 3/4" CUSTOMFCPOT-KETTLE FILLER FAUCETT&S BRASS 1/2"B-0581DSWORK TABLE W/DROP IN SINK CUSTOMCUSTOMLAVLAVATORY1/2" 1/2" 1 1/2" 1 1/2"WCWATER CLOSET1/2" 3" 2"FD FLOOR DRAIN3" 1 1/2"FS FLOOR SINK3" 1 1/2"WH-1WATER HEATER3/4" 3/4"101A COOLER EVAPORATOR KOLPAK3/4"EXISTING109 ICE CUBER MANITOWOC 3/4" 3/4"IY1106A109A WATER FILTRATION SYSTEM SELECTO 3/4"IC620 80-6200110SODA MACHINE CUSTOM1/2" 1 1/2" CUSTOM304 FRYER PITCO FRYALATOR3/4"110,000 SGS-14S305B STOCK POT RANGE IMPERIAL3/4"90,000ISPA-24306VERTICAL BROILERS XL MANUFACTURING1/2"30,000 4LG308 48" COUNTER TOP GRIDDLE VULCAN3/4" 100,000 VCRG48-MAHU-1 AIR HANDLING UNIT3/4" 116,600MAU-1MAKE UP AIR UNIT3/4" 215,000NOTES:1. PROVIDE WITH THERMOSTATIC MIXING VALVE, SET 110°F2. PROVIDE WITH BACKFLOW PREVENTION3. PROVIDE WITH INDIRECT AND INDEPENDENT HARD PLUMBING (COPPER/PVC) TO A FLOOR DRAIN/SINK4. PROVIDE WITH WATER HAMMER ARRESTOR5. EXISTING TO REMAIN6. FUNNEL DRAIN7. FILTERED; FLOOR SINK8. FOR 109, 110, 111, 305B9. EXISTING FLOOR SINK 10. FILTERED NOTE 1 NOTE 1, 3, 9 NOTE 1NOTE 1, 3, 9NOTE 1NOTE 2NOTE 3, 5NOTE 3, 6NOTE 3150,0001/2"CAPTIVE AIREA.O. SMITHMASTER FITCUSTOM3/4"111 BAG-N-BOX CUSTOM1/2"HEIGHT AFF16"36"16"1 1/2"1/2" 1/2"16"16"34"55"78"48"12"12"12"12"W/D WASHER / DRYER EXISTING 1/2" 1/2" 2" 1 1/2"NOTE 2, 4NOTE 7NOTE 848"BY OWNER NOTE 7NOTE 10GAS EQUIPMENT SCHEDULE EQUIP # QTYYAKITORI GRILLFRYER4 BURNER RANGESINGLE BURNER GRIDDLESUMMARY12221MBH EACH1021109090102TOTAL1022201801801021084GAS SIZING IS BASED ON A TOTAL GAS LOAD OF 1084 MBH IN STEEL PIPE AT 0.5 PSI ΔP, WITH LONGEST RUN NOT TO EXCEED 90 FEET.WATER HEATER 2 150 3002524232221191832292827333435363738394045444311423567891312111041412346789101112141326151619171516ELECPANELSELECMETERmopsink BASEMENT ACCESS 1720211GASGASGASGASGASUP TO 2ND FLOOR3/4"ø1"ø1 1/4"ø1 1/4"ø1 1/2"ø2"ø2"ø#8#7#6#5#12#13#3#251' (150 MBH)TO 1ST FLOOR WATER HEATERTO 2ND FLOOR WATER HEATER2"ø26' (150 MBH)77' (1084 MBH)2"øTO 2ND FLOOR WATER HEATER3/4"ø3/4"ø28' (150 MBH)3/4"ø2' (110 MBH)2' (220 MBH)2' (310 MBH)2' (400 MBH)2' (490 MBH)2' (580 MBH)2' (682 MBH)2' (784 MBH)GASDOWN TO 1ST FLOORSHEET TITLE:DRAWING SHEET NO:COPYRIGHT:CHECKED BY:DRAWN BY:DATE:CAD FILE:PROJECT NO:ISSUE:MARKDATEDESCRIPTIONCordell Constructions, Larry Johnson; Phone: 408-221-8126GROUND & 2ND FLGAS SUPPLY PLANSP001The Oxford Kitchen andGastropub110W OAK STREETLODI, CALIFORNIA,92103/16" = 1'-0"1GROUND FLOOR GAS PLAN2GAS RISER DIAGRAM3/16" = 1'-0"5SECOND FLOOR GAS PLAN