Laserfiche WebLink
Underground Storage Tank <br />Secondary Containment Testing Report Form <br />Additional copies of this page may be attached. <br />8. SUMP/UDC TEST <br />Test Method Developed by ® Manufacturer ® Industry Standard ❑ Professional Engineer <br />Test Type ❑ Pressure ❑ Vacuum ® Hydrostatic <br />Test Equipment Used: F.F.S. Incon TS -STS Sump Tester w/ + or — 0.002" graduations <br />Sump/UDC ID <br />UDC 5-6 <br />Diesel STP <br />91 STP <br />UDC 7-8 <br />Sump Manufacturer <br />Bravo <br />Total Containment <br />Total Containment <br />Bravo <br />Sump Depth (inches) <br />12" <br />72" <br />72" <br />12" <br />Sump Bottom to Top of <br />Highest Pipe Penetration <br />inches <br />Piping comes <br />from bottom of <br />UDC <br />28" <br />28" <br />Piping comes <br />from bottom of <br />UDC <br />Test Start Time <br />9:45am <br />9:45am <br />9:45am <br />Initial Reading <br />1.7276" <br />3.8459" <br />5.0850" <br />Test End Time <br />10:00am <br />10:00am <br />10:00am <br />Final Reading <br />1.7274" <br />3.8459" <br />5.0843" <br />Change in Reading <br />-0.0002" <br />0.00" <br />-0.0007" <br />Visual Fail <br />Pass/Fail Criteria <br />+ or — 0.002" <br />+ or — 0.002" <br />+ or — 0.002" <br />+ or — 0.002" <br />Tightness Test Results <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ® Fail <br />Sump/UDC ID <br />UDC 1-2 <br />UDC 3-4 <br />87 STP <br />W.O. <br />Sump Manufacturer <br />Bravo <br />Bravo <br />Total Containment <br />Total Containment <br />Sump Depth (inches) <br />1211 <br />1211 <br />7211 <br />7411 <br />Sump Bottom to Top of <br />Highest Pipe Penetration <br />inches <br />Piping comes <br />from bottom of <br />UDC <br />Piping comes <br />from bottom of <br />UDC <br />28" <br />22" <br />Test Start Time <br />10:18am <br />10:18am <br />12:45pm <br />Initial Reading <br />2.1747" <br />4.0490" <br />4.0792" <br />Test End Time <br />10:33am <br />10:33am <br />1:00pm <br />Final Reading <br />2.1749" <br />4.0479" <br />4.0795" <br />Change in Reading <br />+0.0002" <br />-0.0011" <br />Not tested <br />+0.0003" <br />Pass/Fail Criteria <br />+ or — 0.002" <br />+ or — 0.002" <br />+ or — 0.002" <br />+ or — 0.002" <br />Tightness Test Results <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ® Fail <br />M Pass ❑ Fail <br />Additional copies of this page may be attached. <br />All tests marked "Fail" and any repairs made before or during the tightness test must be described in <br />the COMMENTS section. <br />Page 3 of 5 <br />