Laserfiche WebLink
ABBREVIATIONS <br />SCOPE OF WORK <br />PROJECT <br />SHEET INDEX <br />0 DIAMETER FIN. FINISH PART'N PARTITION <br />D SQUARE FOOT/FEET FIXT. FIXTURE P.L. PROPERTY LINE <br />& AND FLR. FLOOR PLAS. PLASTER <br />@ AT FLUOR. FLUORESCENT PLBG. PLUMBING <br />CENTERLINE F.H. FIRE HYDRANT PLYWD. PLYWOOD <br />(E) EXISTING F.O.M. FACE OF MASONRY P.O.C. POINT OF <br />A.B. ANCHOR BOLT F.O.S. FACE OF STUD CONNECTION <br />ABV. ABOVE F.O.C. FACE OF CONCRETE PR. PAIR <br />A/C AIR CONDITIONING F/S FINISH SURFACE P.T. PRESSURE TREATED <br />A.C. ASPHALTIC CONCRETE F.S. FLOOR SINK <br />A.C.T. ACOUSTIC CEILING TILE F.S.R. FIRE SPRINKLER RISER Q.T. QUARRY TILE <br />A. D. AREA DRAIN FT. FOOT/FEET R. RISER <br />A.F.F. ABOVE FINISH FLOOR F.T. FIRE TREATED RAID. RADIUS <br />ALUM. ALUMINUM FTG. FOOTING R.D. ROOF DRAIN <br />APPROX. APPROXIMATE FLIT. FUTURE RDWD. REDWOOD <br />A.S.R. AUTOMATIC GA. GAUGE RE: REFER TO <br />SPRINKLER ROOM GALV. GALVANIZED REF. REFERENCE <br />ED. BOARD G.C. GENERAL CONTRACTOR REFR. REFRIGERATOR <br />BLDG. BUILDING G. 1. GALVANIZED IRON REINF. REINFORCED <br />ELK. BLOCK GL. GLASS REQ'D. REQUIRED <br />BLKG. BLOCKING GIND. GROUND RESIL. RESILIENT <br />BM. BEAM GR. GRADE RM. ROOM <br />BOT. BOTTOM GYP, GYPSUM R.H.B. RECESSED HOSE BIBB <br />BTWN. BETWEEN H.B. HOSE BIBB R.O. ROUGH OPENING <br />C CAMBER H.C. HOLLOW CORE R.O.W. RIGHT OF WAY <br />C. B. CATCH BASIN HDR. HEADER R.S. RESAWN <br />CEM. CEMENT HOW. HARDWARE S. SOUTH <br />CER. CERAMIC HT. HEIGHT S.C. SOLID CORE <br />C.H.B. CONCEALED HOSE BIBBH.M. HOLLOW METAL SCHED. SCHEDULE <br />C. 1. CAST IRON HORIZ, HORIZONTAL SECT. SECTION <br />C/i CEILING JOIST H.P. HIGH POINT SHT. SHEET <br />C.J. CONTROL JOINT HDVVD. HARDWOOD SHTG. SHEATHING <br />CLG. CEILING HVAC HEATING, VENTILATION & SIM. SIMILAR <br />C.M. CLEAR AIR CONDITIONING SPEC. SPECIFICATION <br />C.M.U. CONCRETE SQ. SQUARE <br />MASONRY UNIT 1. D. INSIDE DIAMETER SSK. SERVICE SINK <br />C/o CLEANOUT 1. E. INVERT ELEVATION SS. STAINLESS STEEL <br />C.O. CONCRETE OPENING IN. INCH STD. STANDARD <br />COL. COLUMN INSUL. INSULATION STL. STEEL <br />CONIC. CONCRETE INT. INTERIOR STOR. STORAGE <br />CONN. CONNECTION JT. JOINT STRUCTSTRUCTURAL <br />CONSTR. CONSTRUCTION S.O.V. SHUT OFF VALVE <br />CONT. CONTINUOUS LAM. LAMINATED SYM, SYMMETRICAL <br />CONTIR.CONTRACTOR LAV. LAVATORY T. TREAD <br />CTSK COUNTERSUNK LT. LIGHT T.B. TOP OF BEAM <br />C.Y. CUBIC YARD MAX. MAXIMUM T.O.C. TOP OF CURB <br />DBL. DOUBLE M.B. MACHINE BOLT TEL. TELEPHONE <br />DEPT. DEPARTMENT MECH. MECHANICAL T&G TONGUE AND GROOVE <br />DIET. DETAIL MET. METAL THK. THICK <br />D.F. DRINKING FOUNTAIN MFR. MANUFACTURER T.J. TRUSS JOIST <br />DIA. DIAMETER M.H. MANHOLE T.O.P. TOP OF PARAPET <br />DIM. DIMENSION MIN. MINIMUM T.O.S. TOP OF SHEATHING <br />ON DOWN MISC. MISCELLANEOUS T.O.W. TOP OF WALL <br />DR DOOR M.O. MASONRY OPENING TYP. TYPICAL <br />DS DOWNSPOUT MTD. MOUNTED U.N.O. UNLESS NOTED <br />DWG. DRAWING MITT MAIN TELEPHONE OTHERWISE <br />EA. EACH TERMINAL <br />E.E. EXTERIOR ELEVATION MUL. MULLION VERT. VERTICAL <br />V.C.T. VINYL <br />E.J. EXPANSION JOINT N. NORTH NO. NUMBER COMPOSITION TILE <br />ELECT. ELECTRICAL N.I.C. NOT IN CONTRACT <br />EL ELEVATION V.T.R. VENT THROUGH ROOF <br />E.O.S. EDGE OF SLAB <br />E. P. ELECTRICAL PANEL NOM NOMINAL W. WEST <br />EQ. EQUAL N.T.S. NOT TO SCALE W/ WITH <br />W.C. WATER CLOSET <br />EQUIP. EQUIPMENT O.A. OVERALL WD. WOOD <br />E.W. EACH WAY O.C. ON CENTER W.H. WATER HEATER <br />EXIST. EXISTING O.D. OUTSIDE DIAMETER W/o WITHOUT <br />EXT. EXTERIOR OFD. OVERFLOW DRAIN W.R. WATER RESISTANT <br />OPG OPENING <br />FDN FOUNDATION W�W.F. WELDED WIRE FABRIC <br />F. D. FLOOR DRAIN OPP� OPPOSITE <br />F.F. FINISH FLOOR <br />CONSTRUCTION OF NEW SINGLE STORY DRIVE THRU RESTAURANT WITH DRIVE-THRU, <br />STONE VENEER, REQUIRED PARKING, LANDSCAPING, AND ACCESS TO PUBLIC WAY. <br />PROJECT NOTES: <br />1. G.C. Shall contact dig alert for location of existing utilities when installing grease interceptor, <br />2. Soils shall be compacted to 90% or greater per soils report. G.C. To provide reports of lifts and compactions to the <br />owner at turn over for verification. <br />3. All the work such as site lighting, trash enclosures, site drainage, drive aisles, curb ramps and accessible parking will be <br />completed as part this project. <br />OPERATING & MAINTENANCE INFO & ENERGY NOTES: <br />a. The builder shall provide to the building owner at occupancy maintenance information for all features, materials. <br />Components and manufactured devices that required routine maintenance for efficient operation. This information shall <br />also be provided to the person (s) responsible for maintaining the feature, material component or mechanical device <br />installed in the building.(2016 CAC (California Administrative Code (Title 24, part 11)) section 10-103(b)2). Refer to 21A100 <br />for additional information. <br />A. The builder shall provide to the building owner at occupancy maintenance information for all features, materials, <br />components and manufactured device that required routine maintenance for efficient operation. Required routine <br />maintenance actions shall be clearly stated and incorporated on a readily accessible label. The label may be limited to <br />identifying, by Title and/orpublication number, the operation and maintenance manual for that particular model and type of <br />feature, material, component or manufactured device. 2016 CAC, 10-103(b)3, Refer to note 2 on a100 for additional info. <br />B. All systems, equipment and/or building components shall comply with applicable manufacturer provisions and <br />installation provision of 2016 California Energy Code (Title 24, part6) subchapter 2, sections 110.0 through 110.9. <br />C. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft2 of <br />window area and door area (2016 California Energy Code, section 110.6) <br />b. Joints and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, <br />weatherstripped, or otherwise sealed to limit infiltration and exfiltration. (2016 California Energy Code section 110.6) <br />c. The heat loss of the water heater storage tank surface, based on an 80 deg, F. Water-air temperature difference shall be <br />less than 6.5 btu/hr per square foot, (2016 California Energy Code section 110.3) <br />d. Insulation shall be certified by the manufacturer as compliant with the California quality standards for insulating material, <br />(2016 California Energy Code section 110.8). N/a, not part of TI scope.SPECIFICATIONS <br />D. Area formaldehyde foam insulation may only be used in exterior side walls, and requires a four-mil-thick plastic <br />polyethylene vapor barrier between the urea formaldehyde foam insulation and the interior space. (2016 California Energy <br />Code section 110.8). N/a, not part of TI scope. <br />E All insulating material shall be installed in compliance with the flame spread rating and smoke density requirements of <br />the California Energy Code. (2016 California Energy Code section 110.8). N/a, not part of TI scope. <br />F. All heating and/or cooling systems shall have an automatic thermostat with clock mechanism or other setback <br />mechanism approved by the executive chrectorofthe California Energy commission that shuts the system off during peak <br />periods of non-use and that allows the building occupant to automatically set back the thermostat set points for at least <br />two periods within 24 hours. (2016 California Energy Code, chapter 7, section 150.0(i) & chapter 2, section 110.2(c)). <br />0 <br />1323 E. YOSEMITE AVE <br />MANTECA, CA 95337 <br />■ <br />STORE 250 <br />CS ?.Ulm 0 00+ <br />Sheet Number <br />SheetTitle <br />I <br />DeltaNumber <br />I <br />o <br />MM <br />GENERAL INFORMATION & LANDSCAPE SHEETS <br />G1100 COVER SHEET <br />G105 SITE PLAN <br />MMMIMM <br />G105.1 SITE DETAILS <br />G105.2 SITE DETAILS <br />G107 TRASH CORRAL PLAN <br />G120 ACCESSIBILITY DETAILS <br />G130 RESPONSIBILITY SCHEDULE <br />G140 CAL GREEN BUILDING STANDARDS <br />G141 CAL GREEN BUILDING STANDARDS <br />G145 CAL GREEN SCHEDULE <br />G150 VOC AND WASTE MANAGEMENT <br />CIVIL SHEETS <br />C1 CIVIL COVER SHEET <br />C1.1 NON-RESIDENTIAL MANDATORY MEASURES <br />C2 SITE PLAN <br />C21 SITE DETAILS <br />C3 GRADING AND DRAINAGE PLAN <br />C4 UTILITY PLAN <br />C5 EROSION CONTROL PLAN <br />Consultant <br />6 <br />Z <br />Z <br />W . 0 <br />■ 0 u <br />Z 'Mi <br />mwo;mo <br />0 - <br />'J <br />Z <br />�<U- <br />> <br />3: Z <br />°m a <br />Ll NOTES AND SPECIFICATIONS <br />L2 PLANTING PLAN <br />L3 IRRIGATION PLAN <br />L4 DETAILS AND SPECS <br />ARCHITECTURAL & STRUCTURAL SHEETS <br />A100 GENERAL REQUIREMENTS AND CONDITIONS <br />--ATTT- 6PLUIFIGA I IUN6 3HEL I I <br />SHEET 2 <br />Ra, I FLOOR PLAN <br />A-4 <br />M DOOR, WINDOW, AND FINISH SCHEDULES <br />A210 REFLECTED CEILING PLAN <br />A225 ROOF PLAN <br />A226 ROOF DETAILS <br />AM FINISH PLAN <br />A240 GRAPHICS PLAN AND SCHEDULE <br />A250 ENLARGED RESTROOM PLANS/ ELEVATIONS <br />A260 FURNITURE AND EQUIPMENT PLAN <br />A300 PARTITION TYPES <br />A400 INTERIOR DETAILS <br />A41 0 INTERIOR DETAILS <br />A500 INTERIOR ELEVATIONS <br />GENERAL NOTES <br />A510 EXIERIOR ELEVATIONS <br />A511 EXTERIOR ELEVATIONS <br />A520 BUILDING SECTIONS <br />1. It is the responsibility of the contractor to field verify existing site conditions and dimensions prior to <br />starting construction. The conditions shown on these documents are based on information supplied <br />from existing blue prints, alta surveys, and/or landlord information. <br />2 If any errors, discrepancies or omissions appear on these drawing, specifications or other contract <br />documents, the contractor shall notify project architect immediately. <br />3. The drawings are not to be scaled. <br />4. These drawing are not to be altered in any way without written authorization from the architect. <br />5. Coordinate construction time and noise requirements with the construction project manager prior to <br />commencement. <br />6. Shop drawings are to be submitted to architect as required by owner. <br />7. Construction pm is responsible to acquire as-built drawings from all subcontractors upon completion <br />of the project and to submit to project architect. <br />8. All coordination between subcontractors shall be based on entire set of documents. No extra <br />compensation will be given to a bidder or supplier who has bid from an incomplete set of <br />construction documents. In case of inconsistencies or discrepancies between drawing the most <br />stringent note or condition shall apply and the contractor shall notify owner/architect immediately of <br />such discrepancies. <br />9. It is the responsibility of the sub-contractor to field verify existing site conditions and dimensions <br />prior to starting construction. <br />10. Interruption of services to the building shall be held to a minimum. Coordinate such interruptions <br />with the owner. Existing services which are in any way affected by the performance of this work <br />shall be protected and maintained, including utility services for the building that originate in or <br />through the space or located within the site premises. <br />11, Drawings and specifications, and all copies thereof are legal instruments of service for the use of <br />the owner and authorized representatives on the designated property only. Other use without the <br />expressed written permission of the architect and/or owner is prohibited. <br />12. Specifications, details and schedules which may be bound separately, are part of these contract <br />documents. Drawings by consulting professionals, such as structural, landscape, etc. Are <br />supplemental to the architectural drawings and are a part of these contract documents U.N.O.. <br />13. Refer to general notes on drawings of other disciplines for additional requirements. <br />14. The term "typical" or 'typ" as used in these documents shall mean that the condition is the same <br />from similar conditions, throughout unless otherwise noted. <br />A530 WALL SECTIONS <br />A531 WALL SECTIONS <br />A610 DOOR & WINDOW DETAILS <br />SG1 GENERAL NOTES <br />UJ <br />> <br />< Cy') <br />UJ LID <br />0) <br />< <br />0 <br />- <br />O < <br />UJ <br />wz <br />CY <br />< <br />04 <br />M <br />LO <br />(N <br />zi� <br />LJJ <br />0 <br />U) <br />SG2 GENERAL NOTES <br />S1.0 FOUNDATION PLAN <br />S2.0 ROOF FRAMING PLAN <br />S3.0 BUILDING SECTIONS <br />GRAPHIC SYMBOLS <br />BUILDING DATA <br />VICINTY MAP <br />SD1 DETAILS AND SECTIONS <br />SD2 DETAILS AND SECTIONS <br />SD3 DETAILS AND SECTIONSM <br /><�> WALL TYPE <br />MATERIAL <br />FINISH <br />FX 1 KEY NOTE <br />O DOOR TYPE <br />WINDOW/ <br />XX STOREFRONT/ <br />CURTAINWALL <br />CEILING <br />HEIGHT <br />REVISION <br />Ax DELTA <br />COLUMN GRID <br />EXISTING <br />COLUMN GRID <br />XXX <br />XXX SPACE NAME / <br />NUMBER/ <br />XXX AREA <br />MATCH LINE <br />SEE: <br />�AXjx <br />MATCH LINE <br />BUILDING WALL SECTION <br />SITE AREA: <br />CONSTRUCTION TYPE: <br />GROSS FLOOR AREA (LEASEABLE): <br />USEABLE INTERIOR AREA: <br />OCCUPANCY GROUP: <br />35�732 SF <br />TYPE V-13 - NON SPRINKLED <br />3,118 SF <br />2,852 SF <br />A-2 <br />AP <br />Project Site7 <br />N <br />PLUMBING SHEETS <br />P100 PLUMBING SPECIFICATIONS AND SCHEDULE <br />P200 SANITARY/ GREASE WASTE PLAN <br />P21 0 WATER AND GAS SUPPLY PLAN <br />P220 FLOOR DRAIN ROUGH-IN PLAN <br />P300 PLUMBING SITE PLAN <br />SQUARE FOOTAGE BREAKDOWN: SEATING & TABLE COUNTS: <br />KITCHEN/ B.O.H. = 873 SF INTERIOR: <br />DINING =1,341 SF SEAT COUNT TABLE COUNT <br />MISC/RESTROOMS/HALL = 638 SF 74 18 <br />TOTAL INTERIOR: 2,852 SF EXTERIOR PATIO: <br />SEAT COUNT TABLE COUNT <br />EXTERIOR PATIO: 309 SF 16 7 <br />P400 PLUMBING RISERS <br />P410 PLUMBING DETAILS <br />MECHANICAL SHEETS <br />MEP100 MECH/ELEC/PLUM ROOF PLAN <br />U) <br />UJ <br />> <br />0 <br />ELEVATION <br />+26-0" SPOT <br />TOPARAPET ELEVATION <br />DETAIL NO <br />BUILDING NO. <br />246 2A <br />A7.1-1B w DETAIL <br />REFERENCE <br />SHEET NO. <br />AXX VIEW TAG <br />N <br />NORTH <br />ARROW <br />(1) <br />B <br />CA MULTI VIEW TAG <br />4( <br />D <br />M100 MECHANICAL SPECIFICATIONS <br />M200 MECHANICAL FLOOR PLAN <br />M300 MECHANICAL SCHEDULES <br />CODE SUMMARY <br />M400 MECHANICAL DETAILS <br />SHELVING STORAGE: <br />STANDARD FLOOR SHELVING: OVERHEAD STORAGE SHELVING: <br />2'-0" DEEP = 21.0 LF + 1'-6" DEEP = 15" DEEP = 20.0 LF <br />TOTAL = 26.0 LF (MOUNTED 7-4- HIGH) <br />M500 HOOD DRAWINGS <br />M510 HOOD DRAWINGS <br />A GENERAL DESCRIPTION <br />CONSTRUCTION OF FREESTANDING RESTAURANT BUILDING WITH DRIVE THRU LANE <br />B. OCCUPANCY <br />1. OCCUPANCY (CHAPTER 3) A-2, B <br />NON-SEPARATED MIXED OCCUPANCIES PER CODE 2016 CBC SECTION 508.3 <br />C GENERAL BUILDING SIZE <br />1. CONSTRUCTION TYPE (CHAPTER 5): V-B <br />FULLY SPRINKLERED BUILDING: NO <br />2. ALLOWABLE STORIES (TABLE 503 & SEC. 504.2): --- <br />ACTUAL STORIES: 1 <br />3. ALLOWABLE HEIGHT (TABLE 503 & SEC. 504.2): 60 FEET <br />ACTUAL HEIGHT: 24'-0" <br />D. TYPE OF CONSTRUCTION <br />1. CONSTRUCTION (SECTION 603): TYPE V-B <br />2. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: <br />PRIMARY STRUCTURAL FRAME (TABLE 601) 0H <br />EXTERIOR BEARING WALL (TABLE 601) 0H <br />INTERIOR BEARING WALL (TABLE 601) OHR <br />EXTERIOR NOWALL @ LESS THAN 30- FIRE SEPARATION (TABLE 602) 1HR <br />EXTERIOR NON-BEARING WALL @ 30- OR MORE FIRE SEPARATION (TABLE 602) 0H <br />INTERIOR NON-BEARING WALL & PARTITIONS (TABLE 601) 0H <br />FLOOR CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS (TABLE 601) 0H <br />ROOF CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS (TABLE 601) 0H <br />E. MAXIMUM OPENING AREA <br />1. OPENINGS NOT LIMITED WHERE YARDS ARE > 30' PER TABLE 705.8 <br />F. ALLOWABLE AREA <br />THE HABIT BURGER GRILL (Building Type Sprinklered): <br />BASIC ALLOWABLE AREA: 5,500 SIF (Table 503) <br />BUILDING AREA (GROSS LEASEABLE): 3,118 SIF TOTAL <br />G. PARKING( Refer to Sheet G105 <br />M600 MECHANICAL TITLE 24 <br />M610 MECHANICAL TITLE 24 <br />M620 MECHANICAL TITLE 24 <br />ELECTRICAL SHEETS <br />MATERIAL SYMBOLS <br />APPLICABLE CODES <br />E100 ELECTRICAL SPECIFICATIONS & NOTES <br />E200 LIGHTING PLAN & NOTES <br />E201 LIGHTING FIXTURE SCHEDULE <br />GYPSUM BOARD ON SHOWN IN SECTION <br />nI[ _�ffli r=,,, �11 <br />I M SHOWN IN SECTION <br />PLASTIC LAMINATE <br />CAST-IN-PLACE CONCRETE SHOWN IN SECTION <br />PLAN OR SECTION <br />CONT. WOOD BLOCKING <br />SHOWN IN SECTION <br />STONE TILE CLADDING <br />PLAN OR SECTION FINISHED WOOD <br />RIGID ROOF INSULATION SECTION OR ELEVATION <br />OR SAFING, PLAN OR OR <br />SECTION FINISHED WOOD <br />STONE: GRANITE, MARBLE, SECTION OR ELEVATION <br />OR AS NOTED <br />SPRAYED FIREPROOFING <br />METAL: TYPE AS NOTED SHOWN IN SECTION <br />PLAN OR SECTION OR <br />SPRAYED FIREPROOFING <br />SHOWN IN SECTION <br />METAL: ROLLED SHAPES <br />PLAN OR SECTION BATT INSULATION: THERMAL <br />OR ACOUSTICAL, LION <br />ACOUSTICAL TILE <br />SHOWN IN SECTION GLASS <br />SECTION <br />RUMRESILIENT FLOORING: VCT, <br />SHEET VINYL, LION CMU <br />SECTION <br />O PLASTER ON METAL LATH r----- LANDSCAPE AREA <br />SHOWN IN SECTION <br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CodeS: <br />0 2016 CALIFORNIA ADMINISTRATION Code (CAC) <br />0 2016 CALIFORNIA BUILDING Code (CBC) <br />• 2016 CALIFORNIA ELECTRICAL Code (CEC <br />2016 CALIFORNIA MECHANICAL Code (CMC)r6ff_ <br />0 2016 CALIFORNIA PLUMBING Code (CPC) <br />0 2016 CALIFORNIA Energy Code (CFC) <br />0 2016 CALIFORNIA FIRE Code <br />a 2016 CALIFORNIA GREEN BUILDING Code <br />THIS PROJECT TO COMPLY WITH ACCESSIBILITY REQUIREMENTS OF 2016 CALIFORNIA BUILDING Code TITLE 24 <br />SECTION 11 B-202. COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA) IS THE RESPONSIBILITY OF THE <br />OWNER, DEVELOPER, CONTRACTOR, DESIGNER AND ARCHITECT. <br />E210 POWER PLAN & NOTES <br />E220 OVERALL ELECTRICAL SITE PLAN <br />E300 ONE-LINE DIAGRAM AND PANEL SCHEDULES <br />E400 PATIO HEATER DETAILS <br />E410 TYPICAL ELECTRICAL DETAILS <br />E500 TITLE 24 COMPLIANCE FORMS <br />TITLE 24 COMPLIANCE FORMS <br />role tNumber. 17-536 <br />Plan Check Number. <br />E­5T2_ TITLE 24 COMPLIANCIET-ORMS <br />PROJECT DIRECTORY <br />rzM TITLE 24 COMPLIANCE FORMS <br />___E5_F4_ <br />TITLE 24 COMPLIANCE FORMS <br />10/12117 ISSUE FOR PERMIT <br />--- <br />____EST617DRI E- ELECTRICAL <br />TENANT: MEP ENGINEERS: <br />THE HABIT BURGER GRILL 17320 RED HILL AVE. AEDIFICA CASE ENGINEERS <br />SUITE 140 IRVINE, CA 92614 796 MERUS COURT <br />P: 949.851.8881 ST. LOUIS, MO 63026 <br />F: 949.852.4650 LUKE WILD <br />W: WWW.HABITBURGER.COM P 636-349-1600 <br />E: LWILD@AEDIFICA.COM <br />ARCHITECT: <br />LINGLE DESIGN GROUP STRUCTURAL ENGINEERS: <br />158 WEST MAIN STREET AEDIFICA CASE ENGINEERS <br />LENA, IL 61048 796 MERUS COURT <br />DREW GOEKE ST. LOUIS, MO 63026 <br />P: 815.369.9155 JEFF LEEKER <br />E: DREWGOEKE@LINGLEDESIGN.COM P: 636-349-1600 <br />E: JLEEKER@AEDIFICA.COM <br />RESTAURANT DESIGN CONSULTANT: TRIMARK <br />RAYGAL FOODSERVICE DESIGN, 92614MENTQUIPCIVIL ENGINEER: <br />AND SUPPLIES MILESTONE ASSOCIATES IMAGINEERING <br />2801 MCGAW AVENUE IRVINE, CA 1000 LINCOLN ROAD, STE H202 <br />MIKE BRADY YUBA CITY, CA 95991 <br />P: 949.474.1000 JULIO TINAJERO <br />E: MBRADY@TRIMARKUSA.COM P: 530-755-4700 <br />W: TRIMARKUSA.COM E: JTINAJERO@MILESTONE-AE.COM <br />FOOD SERVICE SHEETS - FOR REFERENCE ONLY <br />FS010 COVER SHEET AND NOTES <br />FS200 EQUIPMENT PLAN <br />DEFERRED SUBMITTAL <br />FS205 EQUIPMENT SCHEDULE <br />FS21 0 PLUMBING PLAN <br />FS220 ELECTRICAL PLAN <br />SEPARATE APPLICATIONS, PLAN CHECKS, AND/OR PERMITS ARE REQUIRED FOR: <br />1. SIGN AND SIGNAGE <br />2. FIRE ALARM <br />3. CIVIL/ LANDSCAPE SITE IMPROVEMENTS <br />FS230 BUILDING CONDITION PLAN <br />FS500 EQUIPMENT KEY PLAN & ELEVATIONS <br />FSH E E T <br />A <br />G100 <br />FS510 EQUIPMENT ELEVATIONS <br />