Laserfiche WebLink
Component Description <br />Wet Chemical Agent -The extinguishing agent is a mixture of <br />organic salts designed for rapid flame knockdown and foam <br />securement of grease related fires. It is available in plastic <br />containers with instructions for wet chemical handling and usage. <br />Agent Tank - The agent tank is installed in a stainless steel enclo- <br />sure or wall bracket. The tank is constructed of stainless steel. <br />Tanks are available in two sizes: 1.5 gallon (6.7 L) and 3.0 gallon <br />(11.4 Q. The tanks have a working pressure of 110 psi (7.6 bar), a <br />test pressure of 330 psi (22.8 bar), and a minimum burst pressure <br />of 660 psi (45.5 bar). <br />The tank includes an adaptor/tube assembly. The adaptor assem- <br />bly includes a chrome -plated steel adaptor with a 1/4 in. NPT <br />female gas inlet, a 3/8 in. NPT female agent outlet, and a stainless <br />steel agent pick-up tube. The adaptor also contains a bursting <br />disc seal which helps to prevent the siphoning of agent up the <br />pipe during extreme temperature variations. <br />Regulated Release Mechanism -The regulated release mecha- <br />nism is a spring-loaded, mechanical/pneumatic type capable of <br />providing the expellant gas supply to one, two, or three agent <br />tanks depending on the capacity of the gas cartridge used. It <br />contains a factory installed regulator deadset at 110 psi (7.6 bar) <br />with an external relief of approximately 180 psi (12.4 bar). It has <br />automatic actuation capabilities by a fusible link detection system <br />and remote manual actuation by a mechanical pull station. <br />The regulated release mechanism contains a release assembly, <br />regulator, expellant gas hose, and agent storage tank housed in <br />a stainless steel enclosure with cover. The enclosure contains <br />knock -outs for 1/2 in. conduit. The cover contains an opening for <br />a visual status indicator. <br />It is compatible with mechanical gas shut-off devices; or, when <br />equipped with a field or factory -installed switch and manual reset <br />relay, it is compatible with electric gas line or appliance shut-off <br />devices. <br />Regulated Actuator Assembly- When more than two agent <br />tanks (or three 3.0 gallon (11.4 L) tanks in certain applications) are <br />required, the regulated actuator is available to provide expellant <br />gas for additional tanks. It is connected to the cartridge receiver <br />outlet of the regulated release mechanism providing simultane- <br />ous agent discharge. It contains a regulated actuator deadset at <br />110 psi (7.6 bar) with an external relief of approximately 180 psi <br />(12.4 bar). It has automatic actuation capabilities using pressure <br />from the regulated release mechanism cartridge. <br />The regulated actuator assembly contains an actuator, regulator, <br />expellant gas hose, and agent tank housed in a stainless steel <br />enclosure with cover. The enclosure contains knockouts to permit <br />installation of the expellant gas line. <br />Discharge Noules- Each discharge nozzle is tested and listed <br />with the R-102 system for a specific application. Nozzle tips are <br />stamped with the flow number designation (1/2,1, 2, or 3). Each <br />nozzle must have a metal or rubber blow -off cap to keep the <br />nozzle tip orifice free of cooking grease build-up. <br />Agent Distribution Hose- Kitchen appliances manufactured <br />with or resting on casters (wheels/rollers) may include an agent <br />distribution hose as a component of the suppression system. This <br />allows the appliance to be moved for cleaning purposes without <br />disconnecting the appliance fire suppression protection. The hose <br />assembly includes a restraining cable kit to limit the appliance <br />movement within the range (length) of the flexible hose. <br />Flexible Conduit- Flexible conduit allows for quicker installations <br />and the convenience of being able to route the cable over, under <br />and around obstacles. Flexible conduit can be used as a substi- <br />tute for standard EMT conduit or can be used with EMT conduit. <br />Flexible conduit can be used only with the Molded Remote <br />Manual Pull Station. <br />Pull Station Assembly - The remote manual pull station is made <br />out of a molded red composite material. The red color makes the <br />pull station more readily identifiable as the manual means for fire <br />suppression system operation. <br />The pull station is compatible with the ANSUL Flexible Conduit. <br />Approvals <br />• ULNLC Listed <br />• CE Marked <br />• New York City Department of Buildings <br />• LPCB <br />• TFRI <br />• Marine Equipment Directive (MED) <br />• DNV <br />• ABS <br />• Lloyd's Register <br />• Meets requirements of NFPA 96 (Standard for the Installation of <br />Equipment for the Removal of Smoke and Grease -Laden Vapors <br />from Commercial Cooking Equipment) <br />• Meets requirements of NFPA 17A (Standard on Wet Chemical <br />Extinguishing Systems) <br />Ordering Information <br />Order all system components through your local authorized <br />ANSUL Distributor. <br />