EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
285
>
4200 – Liquid Waste Program
>
SR0085142_OWTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 3:12:14 PM
Creation date
4/14/2022 2:06:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
FileName_PostFix
OWTS
RECORD_ID
SR0085142
PE
4201
FACILITY_NAME
285 S AUSTIN RD
STREET_NUMBER
285
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
22802048
ENTERED_DATE
4/13/2022 12:00:00 AM
SITE_LOCATION
285 S AUSTIN RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'IN 's% SAN JOAQUIN <br />COUNTY <br />Greatness grows here. <br />Environmental Health Department <br />Jasjit Kang, REF'S, Director <br />Muniappa Naidu, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Willy Ng, REHS <br />Melissa Nissim, REHS <br />Steven Shih, REHS <br />Michelle Henry, REHS <br />April 21, 2022 <br />ACORN ONSITE, INC <br />2288 BUENA VISTA AVENUE <br />LIVERMORE, CA 94550 <br />RE: Onsite Wastewater Treatment System <br />Address: 285 S. Austin Road, Manteca <br />APN 22802048, SR0085142 <br />The San Joaquin County Environmental Health Department (EHD) has reviewed Onsite <br />Wastewater Treatment System (OVVTS) for the above noted location, and has the following <br />comments for your consideration. <br />Based on the information provided, the EHD concurs with the proposed engineer design septic <br />system with the following conditions: <br />The engineered OVVTS shall be installed according to the designs found in the revised <br />plans received April 21, 2022, obtain a residential engineered OVVTS permit (SJC OVVTS <br />Standard 2.1). <br />The engineered OVVTS shall be operated and maintained pursuant to the Operations <br />and Maintenance Requirements found in the revised site plans received April 21, 2022 <br />(SJC OVVTS Standard1.12.1). <br />An Annual Operating Permit is required for this engineered septic system. Annual <br />sampling for Nitrate (as Nitrogen) is required in the influent and effluent sides of the <br />treatment system; sampling results shall be submitted to EHD when they become <br />available. Sampling shall be done by a state certified laboratory. (SJC OWTS Standard <br />2.10) <br />The onsite domestic well shall be sampled annually for Nitrate (as Nitrogen); the results <br />shall be submitted to EHD when they become available. The samples shall be analyzed <br />by a state certified laboratory. (SJC OVVTS Standard 2.10) <br />Audible and visible alarms are required in the pump tank. The alarms must be set to <br />signal at the "time-to-pump" and "exceeding reserve storage volume" levels. The audible <br />and visual alarms must be located in an area where they are easily seen and heard. <br />Testing of the audible and visual alarm is required before final approval. (SJC OVVTS <br />Standard 10.5) <br />Before final approval of the OVVTS permit, EHD shall witness the hydraulic loading test <br />(squirt test). Call a minimum of 24 hours before squirt test to schedule an inspection; call <br />(209) 953-7697 for inspection line. (General Construction Notes 4.4) <br />1868 E. HazeIton Avenue I Stockton. California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.