Laserfiche WebLink
LEGEND ■ <br /> PROPOSED MANHOLE AND COVER PER DETAILS 5 AND 6 ON SHEET <br /> 7 \ • C7.1 <br /> C7.2 ■ ■ ■ \ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ® PROPOSED DRAIN INLET PER DETAIL 16 ON SHEET C7.0 <br /> \ tt t G ® PROPOSED SANITARY SEWER CLEANOUT PER DETAIL 18 ON SHEET <br /> C7.0 <br /> 15 SDDI 3I � H GATE VALVE PER DETAIL 9 ON SHEET C7.1 <br /> - - - - - - - - - - - - - - - - <br /> NV 13 36 6"S - - - - - - - 4"SS - - - - - - ® POST INDICATOR VALVE PER DETAIL 10 ON SHEET C7.1 S I E G F R I E D <br /> ' \ <br /> S=0.0016 @ 70LF PERF � � � - - - - - - - 4"SS S=0.0016 @ 70LF PERF PROPOSED FIRE DEPARTMENT CONNECTION PER DETAIL 3 ON SHEET <br /> INV 1 1 4% C7.1 3428 Brookside Road NV 16.084"W 4"SS - - - - - - - i - - - - - - - 4"SS - - Stockton,California 95219 <br /> 2"SSFM S=0.0016 @ 701-F PERF S=0.0016 @ 701-F PERF PROPOSED FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 209-943-2021 <br /> 14LF @ S=0.0000 I \ I SSDB 2 Fax: 209-942-0214 <br /> 32LF @ S=0.0000 4"SS - - - - I I 4"SS - - INV 16.58 4"E SS PROPOSED SANITARY SEWER LINE www.siegfriedeng.com <br /> 4"SSFM S=0.0016 @ 70LF PERF _- <br /> S=0.0016 @ 701-F PERF <br /> 4"SSFM I 2"SSFM SS PROPOSED PERFORATED PIPE <br /> - - - 4"SS - - - - - - - - - - - - - - 4"SS - - 4 36LF@S=0.0000 47LF @ S=0.0000 PERF <br /> S=0.0016 @ 70LF PERF I I S=0.0016 @ 70LF PERF SSFM PROPOSED SANITARY SEWER FORCE MAIN <br /> I - <br /> - - SD PROPOSED STORM DRAIN LINE <br /> S=0.0016 @ 70LF PERF - - - - - - - - - - - - - - - - - J 4"SS Q�OF SC <br /> ESS/0 <br /> . �� <br /> S-00016@70LFPERF <br /> �� - - - - - - - - - - - - - - - - - - W� PROPOSED WATER LINE <br /> FS PROPOSED FIRE SERVICE LINE <br /> 00 LO I <br /> o FH PROPOSED FIRE HYDRANT LINE p: 09/3 /23 <br /> z. <br /> Y) \ \ s�gTF FSA <br /> KEY NOTES <br /> J <br /> SDDI 13 DATE SIGNED: 01/28/22 <br /> 16 RIM 15.72 O FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 <br /> INV 12.67 12"S <br /> 4"WATER METER AND BACKFLOW PREVENTER PER C.O.T. <br /> O <br /> SDMH 3 SDMH 2 ,�, . STANDARD PLAN 404&406 <br /> SDDI 1 <br /> SDMH 5 SDMH 4 7 7 RIM 16.75 7 RIM 16.79 Mo \ RIM 16.26 16 O SEE FIRE SPRINKLER PLANS FOR CONTINUATION <br /> RIM 16.85 7 RIM 16.73 INV 12.66 18"W INV 12.59 24"W o <br /> INV 13.07 12"SW INV 12.92 15"W INV 12.44 24"W <br /> INV 13.07 15"E INV 12.92 18"E INV 12.66 24"E INV 12.59 24"E N cn INV 12.44 24"E <br /> INV 12.92 12"S INV 12.66 12"S INV 12.59 18"E � INV 12.44 12"SE O SEE PLUMBING PLANS FOR CONTINUATION <br /> INV 13.07 6"N 97LF @ S=0.0015 174LF @ S=0.0015 �/F18�( U015 N 99LF @ S=0.0015 222LF @ S=0.0015 O 10"DOUBLE CHECK DETECTOR BACKFLOW PREVENTION <br /> 15"SD 18"SD 24"Sp 24"SD 24"3D 5 ASSEMBLY PER DETAIL 18 ON SHEET C7.0 <br /> RIM 16.22 15 SANITARY SEWER PUMP STATION WITH FLOW METER <br /> INV 13.28 12"S O"�O 18„ O PER DETAIL 2 ON SHEET C7.2.SEE DETAIL FOR PUMP SIZING <br /> INV 13.28 12"NE x,,00 624P@ S�Q \ INFORMATION <br /> SDDI 6 0015 O STORM DRAIN MANHOLE AND COVER PER DETAIL 5&6 ON <br /> 16 RIM 16.10 \ SHEET C7.1 <br /> 1010 INV 12.68 18"SE 24 <br /> INV 12.6818"W � 72„ O SANITARY SEWER CLEANOUT PER DETAIL 17 ON SHEET C7.0 <br /> 10TH 10"FH <br /> 0 "FH <br /> 0 10"FS 002 15 SDDI 2 O GATE VALVE AND VALVE BOX PER DETAIL 9 ON SHEET C7.1 <br /> (\I 24 \ RIM 15.48 <br /> CD ® ® 0 10 INV 12.65 12"NW 10 THRUST BLOCK PER DETAIL 4 ON SHEET C7.1 <br /> o <br /> @� CSI 9 1 11 FIRE DEPARTMENT CONNECTION PER DETAIL 3 ON SHEET C7.1 <br /> 12 2" IRRIGATION METER AND BACKFLOW PREVENTER PER <br /> DETAIL 7 ON SHEET C7.1 <br /> U- U- 24 IRRIGATION POINT OF CONNECTION. SEE LANDSCAPE PLANS <br /> 13 FOR CONTINUATION <br /> 14 CONNECT TO EXISTING 12"FIRE HYDRANT LOOP <br /> 17 <br /> 9"'� 15 12"X12"DRAIN INLET PER DETAIL 15 ON SHEET C7.0 <br /> SDTD 1 SDTD 1 S� <br /> = RIM 15.83 RIM 15.83 ��S \�Op 16 24"X24"DRAIN INLET PER DETAIL 15 ON SHEET C7.0 <br /> INV 13.07 12"N INV 12.8112"N �c - <br /> s 17 TRENCH DRAIN PER DETAIL 16 ON SHEET C7.0 <br /> ° CONTRACTOR TO VERIFY EXISTING INVERT AND NOTIFY PHELAN <br /> 3 4 3 4 18 ENGINEER IMMEDIATELY OF ANY CONFLICTS D EVELOPM ENT <br /> 19 CONNECT TO EXISTING STORM DRAIN INLET 450 Newport Center Drive, Suite 230 <br /> 10 Newport Beach, CA 92660 <br /> N 20 ADJUST TO GRADE <br /> 141)U <br /> 21 5000 GALLON SEPTIC TANK PER DETAIL 1 ON SHEET C7.2 <br /> LU <br /> = 22 2"BACKFLOW PREVENTER PER DETAIL 7 ON SHEET C7.1 BUILDINGS H& <br /> LU 23 4X4X4 TEE WITH 2-1/2"REDUCERS ON NORTH AND EAST LEGS HOLLY COMMERCE CENTER <br /> 24 WATER CROSSING PER DETAIL 11 ON SHEET C7.1 <br /> 1 9 10 7 SDMH 6 Z 6"SS LATERAL TO FIRE PUMP ROOM FLOOR DRAIN.TEST FLOW <br /> RIM 17.85 214E 12"Sp O 25 SHALL BE LIMITED TO 100 GALLONS TWICE A YEAR DO TO SEPTIC <br /> INV 12.9715"S @ S;p�� H TANK AND LEACH FILED LIMITATIONS. <br /> EXISTING ° ° ° ° ° ° ° ° INV 12.97 18"NW SDDI 11 Q <br /> 9375 SUGAR RD <br /> ddl- <br /> PROPERTY INV 12.97 12"E RIM 17.56 <br /> LINE U) INV 13.13 12" Z TRACY, CA 95304 <br /> H <br /> Z <br /> O <br /> co <br /> V UTILITY CONSTRUCTION NOTES <br /> CD <br /> g SSWYE 6 MILESTONES: <br /> 11 INV 16.32 6"W O 28 JANUARY 2022 <br /> o � 5 INV 16.32 6"S ILL 1. ALL MATERIALS AND CONSTRUCTION PROCEDURES WITHIN THE SCOPE OF BUILDING DEPARTMENT SUBMITTAL <br /> J C INV 16.32 6"E <br /> LL <br /> 1 THIS CONTRACT SHALL CONFORM TO ALL APPLICABLE SAN JOAQUIN <br /> Co N v 29LF @ SSCO 6 COUNTY STANDARD SPECIFICATIONS(LATEST EDITION)AND THE <br /> C14 co 8 CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD <br /> SSCO 7 S=0.0050 INV 16.33 6 W <br /> 8 25 6"SS SPECIFICATIONS(LATEST EDITION). <br /> RIM 19.98 6 SS <br /> BUILDING H INV 16.47 6"E 2LF @ S=0.0050 <br /> o"Fs EXISTING UTILITIES <br /> 10 <br /> 11 <br /> N 1. EXISTING UTILITY DATA SHOWN ON THIS LAYOUT WAS OBTAINED FROM A <br /> CD SURVEY OF THE VISIBLE FEATURES AT THE SITE AND PUBLIC RECORD <br /> CD <br /> 11 M MAPS OBTAINED FORM UTILITY COMPANIES. REVISIONS: <br /> 4 3 0 -j 2. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES WITHIN 48 <br /> CD co HOURS PRIOR OF CONSTRUCTION TO LOCATE AND TAG THEIR <br /> 1U- UNDERGROUND FACILITIES PRIOR TO EXCAVATION. <br /> H0 Q0 9 o <br /> J 3. THE CONTRACTOR NEEDS TO ALLOW FOR THE POSSIBILITY OF <br /> o UNDETECTED UNDERGROUND UTILITIES.ALSO,THE CONTRACTOR MUST <br /> CD SSWYE 5 ALLOW FOR CHANGES DUE TO UTILITIES BEING IN LOCATIONS DIFFERENT <br /> INV 15.92 6"N <br /> FROM THOSE SHOWN ON THE UTILITY RECORD DRAWINGS.THE <br /> o CONTRACTOR IS RESPONSIBLE FOR LOCATING AND EXPOSING CONFLICTS <br /> INV 15.92 6"S PRIOR TO CONSTRUCTION. <br /> g INV 15.92 6"W <br /> SSCO 5 SSCO 4 4. THE LOCATIONS AND DEPTHS OF EXISTING UTILITIES SHOWN ON THESE <br /> 4 8 RIM 19.98 29LF @ RIM 18.73 8 PLANS ARE APPROXIMATE ONLY.ACTUAL LOCATIONS AND DEPTHS OF <br /> J I INV 16.07 6"E S=0.0050 INV 15.91 6"IT UTILITIES MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO <br /> 6"SS INV 15.91 6"S CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO <br /> LOCATE UTILITY SERVICE LINES AS REQUIRED FOR CONSTRUCTION AND <br /> U 1/2" NOTIFY THE ENGINEER OF ANY CONFLICTS IMMEDIATELY.ANY DAMAGE BY <br /> SSWYE 1 <br /> I SSCO1 SSCO 2 10 THE CONTRACTOR TO EXISTING UTILITIES,WHETHER SHOWN ON THE <br /> � <br /> CD INV 13.23 6"E RIM 19.98 SSWYE 2 SSWYE 3 RIM O 2 4 O PLANS OR NOT,SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO <br /> SDDI 7 REPAIR,AT HIS EXPENSE. <br /> INV 13.23 6"W INV 13.44 6"S INV 13.31 6"E INV 14.26 6"E INV 14.37 6"S RIM 17 <br /> UJI LO 16 INV 13.2915" <br /> INV 13.23 INV 13.31 6"W INV 14.26 6"W il INV 13.29 15" <br /> I SDD15 4 8 <br /> V) RIM 17 60 I 31 6"N 00 INV 14.26 6"N 0 cii INV 13.29 12" <br /> INV 14,15 12"N <br /> = 6"SS <br /> 6"SS p <br /> N 26LF o 22LF @ S=0.0050 0 15 �F @ <br /> z 15 =0.0050LO <br /> 6"SD <br /> 0 <br /> � W <br /> 15LF @ 6"SS INV 15.66 66 6"E 000S 0002 <br /> m S=0.0050 5LF <br /> W <br /> S 0 1 INV 15.66 6" <br /> V) <br /> 191 LF <br /> 6"SS 6"SS „ <br /> I -0.0050 281 LF @ -0.0050 <br /> 9 15"Sp 2LF 10 <br /> 15"S D <br /> Iz 6 21 1 10 219LF @ S=0.0020 121 LF @ S=0.0020 S=0.0050 <br /> w 10TH 10"FH 10"FH 23 <br /> SSPS 1 SEPTIC TANK 1(OUT) SEPTIC TANK 1(IN) 4"W 112" <br /> o RIM 18.34 RIM 18.70 RIM 18.94 16 RIM 18.42 ORIM 18.80 10 SDDI 8 SSCO 3 <br /> RIM 18.80 9 10 16 <br /> 0- _ _ _ INV 16.0- _ _ INV12.92_6W _ _ _INV13.176_E_ _ _ _ - - - - - - - - - - - - - - - -INVU.0�15"E- - - INV 11.5212 N - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ _ _ - - - - - - - - - - - - - - - - - - - - - - - 16 - - g <br /> INV 12.85 6"E INV 12.92 6"E INV 13.17 6"W INV 9.22 12"S �N13 6�151LW �p� Igpgg <br /> - - - - - - - <br /> INV 13.66 15"E ESDCB RSM 16 27 INV 13.42 15"W INV 15.67 6"W I PROJECT: 17017 <br /> a 6"SS INV 8.9718"E RIM 19.00 � <br /> < 32LF @ S=0.0050 INV 9.21 12"S INV 8.97 18"W " INV 13.42 15"NE <br /> F:\17projects\17017 Holly Sugar Industrial\Improvement <br /> �1r <br /> N -- T 2� FILE: plans\BUILDINGSH&I\Onsite\17017-05.1-UTILITY PLANI.dwg <br /> M SS STUB INV 9.50 18"W 12 13 22 <br /> Z INV 13.39 6"N 2 - - ULTIMATE RIGHT OF WAY - - - - - - - - - - - DATE: 1/28/2022 <br /> _ _ <br /> 5 �H OH OH •_• _ _• _ "" OHs_ OH OH OH E� OH OH OH O OH O OH O\H OH - OH -OI-r- ' OH OH- OH OH- OH --ehr Y71"� OH OH OH OH <br /> CD Cf) - - - - - - - - -m- - -/ DRAWN BY: LSF/MWK <br /> EXISTING RIGHT OF WAY \ �o o <br /> J 18"SD . - . - . .- . - . - - . - . <br /> • � SHEET TITLE: <br /> ARBOR AVENUE - - - 12„W UTILITY PLAN I <br /> 0 <br /> C) p 12"W 12 W <br /> o <br /> U NLLI <br /> N <br /> 0 Know what's below. _ o' 10' 20' 40' <br /> C111beforeyou dig. - - - - - - - - - - - - - - . - _ - - - - - - - -- -- - <br /> c5 ■ <br /> - SCALE: 1"=20' 1 <br /> UNIFORM DRAWING SYSTEM - U.S.NATIONAL CAD STANDARD VERSION 3.1 <br />