Laserfiche WebLink
F <br /> SDD123 LEGEND <br /> IF RIM 18.16 15 ■ <br /> SDDI 18 16 1 SDDI 19 16 1 9 co o INV 12.99 6T PROPOSED MANHOLE AND COVER PER DETAILS 5 AND 6 ON SHEET <br /> •- 100LF RIM 19.81 RIM 19.81 -Co <br /> SDMH 8 C7.1 <br /> ESDDI @ 5=0.0025 INV 12.0418"E 9 INV 12.4515"E j RIM 18.76 7 <br /> 18 19 20 RIM 20.31 18"SD 163LF @ S=0.0025 INV 12.4518"W INV 12.80 1 "S I ® PROPOSED DRAIN INLET PER DETAIL 16 ON SHEET C7.0 <br /> 18"SD 15"SD INV 12.80 1 "W <br /> INV 11.7918"E 142LF S=0.0025 � INV 12.80 1N I e PROPOSED SANITARY SEWER CLEANOUT PER DETAIL 18 ON SHEET <br /> `° 2"SSFM SSPS 2 1 /1\ <br /> IC7.0 <br /> RIM 18.59 427LF @ S=0.0000 RIM 19.16 ►� GATE VALVE PER DETAIL 9 ON SHEET C7.1 <br /> INV 11.79 36"N INV 14.04 6�' <br /> / 10"FH 10"FH INV 16.58 21' / ® POST INDICATOR VALVE PER DETAIL 10 ON SHEET C7.1 No <br /> 10 10 10 10 21 60LFD @ S=d10050 I PROPOSED FIRE DEPARTMENT CONNECTION PER DETAIL 3 ON SHEET S I E G F R I E D <br /> 14 10"FH SEPTIC TAf�IK 2(OUT) I � C7.1 <br /> RIM 19.41 (5 PROPOSED FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 3428 Brookside Road <br /> LL o I INV 14.09 6' Stockton,California 95219 <br /> o INV 14.09 6I 209-943-2021 <br /> o <br /> PROPOSED SANITARY SEWER LINE <br /> SEPTIC TA .K 2(IN) Fax: 209-942-0214 <br /> 10"FH I I SS PROPOSED PERFORATED PIPE www.siegfriedeng.com <br /> DIM zo INV 14.34 6 <br /> U) � RIM 19.83 I' PERF <br /> 10 10 co INV 14.34 6'i I SSFM PROPOSED SANITARY SEWER FORCE MAIN <br /> 6"SS <br /> g��pppp SSCO 9 48LF @ S=0.0050 N I SD PROPOSED STORM DRAIN LINE <br /> 4 8 RIM 21.46 0 <br /> X� o INV 14.69 6"E NV 14.45 6"S iii �W PROPOSED WATER LINE Q�OFESS/0 <br /> ppm o INV 14.45 6"N Cn �� •SCy l <br /> 2 SSFM U INV 14.45 6"W I I FS PROPOSED FIRE SERVICE LINE �� I F2 <br /> O <br /> 47LF @ S=0.0000 J N M i I FH PROPOSED FIRE HYDRANT LINE w d .� m <br /> • I I P. 09/3 /23� <br /> JL • KEY NOTES ��qTF FSA <br /> Al e I <br /> ° ° ° 1 FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 <br /> � I DATE SIGNED: 01/28/22 <br /> O 4"WATER METER AND BACKFLOW PREVENTER PER C.O.T. <br /> STANDARD PLAN 404&406 <br /> 0 <br /> I O SEE FIRE SPRINKLER PLANS FOR CONTINUATION <br /> ZD <br /> . 40 SEE PLUMBING PLANS FOR CONTINUATION <br /> II 5 8" DOUBLE CHECK DETECTOR BACKFLOW PREVENTION <br /> O ASSEMBLY PER DETAIL 18 ON SHEET C7.0 <br /> i SANITARY SEWER PUMP STATION WITH FLOW METER <br /> OPER DETAIL 2 ON SHEET C7.2.SEE DETAIL FOR PUMP SIZING <br /> 0 <br /> SDMH 1 SDDI 20 INFORMATION <br /> 7 15 STORM DRAIN MANHOLE AND COVER PER DETAIL 5&6 ON <br /> RIM 18.04 RIM 19.47 07 <br /> INV 12.11 24"W o INV 13.13 1 "g SHEET C7.1 <br /> INV 12.11 24"N ° ° ° o I INV 13.13 115"N I O SANITARY SEWER CLEANOUT PER DETAIL 17 ON SHEET C7.0 <br /> 222LF @ S=0.0015 INV 12.11 18"S <br /> 24"Sp INV 12.11 12"SE <br /> U- O GATE VALVE AND VALVE BOX PER DETAIL 9 ON SHEET C7.1 <br /> -i I <br /> I <br /> 10 THRUST BLOCK PER DETAIL 4 ON SHEET C7.1 <br /> 66<F@S'000 <br /> 0 I I 11 FIRE DEPARTMENT CONNECTION PER DETAIL 3 ON SHEET C7.1 <br /> 00SDDI 14 20 RIM 16.80 15 1" IRRIGATION METER AND BACKFLOW PREVENTER PER <br /> INV 12.24 12"NW I 12 DETAIL 7 ON SHEET C7.1 <br /> 10"FH I 1 13 IRRIGATION POINT OF CONNECTION.SEE LANDSCAPE PLANS <br /> 10 10 FOR CONTINUATION <br /> 14 CONNECT TO EXISTING 12" FIRE HYDRANT LOOP <br /> e I <br /> • I 15 <br /> ° ° ° 12"X12"DRAIN INLET PER DETAIL 15 ON SHEET C7.0 <br /> 10 9 1 � I <br /> ® 16 24"X24" DRAIN INLET PER DETAIL 15 ON SHEET C7.0 <br /> 8"FH I <br /> LO <br /> 10"FS 17 TRENCH DRAIN PER DETAIL 16 ON SHEET C7.0 <br /> GV <br /> 3 4 o CONTRACTOR TO VERIFY EXISTING INVERT AND NOTIFY <br /> oI 18 ENGINEER IMMEDIATELY OF ANY CONFLICTS <br /> PHELAN <br /> `r2 I 19 CONNECT TO EXISTING STORM DRAIN INLET <br /> C:) J D EVELOPM ENT <br /> o00 <br /> I 20 ADJUST TO GRADE 450 Newport Center Drive, Suite 230 <br /> LID ADJUST Beach, CA 92660 <br /> 21 5000 GALLON SEPTIC TANK PER DETAIL 1 ON SHEET C7.2 <br /> LL1 Q0 <br /> BUILDING I 4 8 SSC010 <br /> RIM 5.48 6"E 46LF 6��SS 0.0050 <br /> 15.64 <br /> INV I I 22 10"BACKFLOW PREVENTER PER DETAIL 7 ON SHEET C7.1 <br /> (n C3 SSWYE 8 I RELOCATE EXISTING AIR RELEASE VALVE PER C.O.T.STANDARD <br /> IW INV 15.41 6"S 23 PLAN 408 BUILDINGS H& <br /> V� \ INV 15.41 6"N I 6"SS LATERAL TO FIRE PUMP ROOM FLOOR DRAIN.TEST FLOW HOLLY COMMERCE CENTER <br /> INV 15.41 6"W 24 SHALL BE LIMITED TO 100 GALLONS TWICE A YEAR DO TO SEPTIC <br /> Z <br /> O 8"FHIQ I TANK AND LEACH FILED LIMITATIONS. <br /> c <br /> Q 10 9 1 <br /> z I UTILITY CONSTRUCTION NOTES 9375 SUGAR RD <br /> Z 7 I I� TRACY, CA 95304 <br /> U I 1. ALL MATERIALS AND CONSTRUCTION PROCEDURES WITHIN THE SCOPE OF <br /> THIS CONTRACT SHALL CONFORM TO ALL APPLICABLE SAN JOAQUIN <br /> 0 COUNTY STANDARD SPECIFICATIONS(LATEST EDITION)AND THE <br /> 21�F <br /> 12" I I CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD <br /> O <br /> ILL0 SDD@1 \0"0080 I SPECIFICATIONS(LATEST EDITION). MILESTONES: <br /> UARY 2022 <br /> RIM 17.56 R M 18 32 7 ° ° ° I BUILDING DEPARTMEN28 T SUBMITTAL <br /> INV 13.13 12"W INV 12.44 12"S SDDI 1515 a EXISTING UTILITIES <br /> INV 12.44 18"N RIM 16.88 a <br /> INV 12.44 12"E INV 12.56 12"W SDDI 21I <br /> 12"SD RIM 19.47 15 I 1. EXISTING UTILITY DATA SHOWN ON THIS LAYOUT WAS OBTAINED FROM A <br /> 59LF E=0.0020 o INV 13.57 2"S SURVEY OF THE VISIBLE FEATURES AT THE SITE AND PUBLIC RECORD <br /> CD INV 13.57 5"N I MAPS OBTAINED FORM UTILITY COMPANIES. <br /> CD <br /> o I <br /> � <br /> 2. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES WITHIN 48 <br /> @ o HOURS PRIOR OF CONSTRUCTION TO LOCATE AND TAG THEIR <br /> UNDERGROUND FACILITIES PRIOR TO EXCAVATION. <br /> 16 I 3. THE CONTRACTOR NEEDS TO ALLOW FOR THE POSSIBILITY OF REVISIONS: <br /> UNDETECTED UNDERGROUND UTILITIES.ALSO,THE CONTRACTOR MUST <br /> O15 ° ° ° LL ALLOW FOR CHANGES DUE TO UTILITIES BEING IN LOCATIONS DIFFERENT <br /> o I FROM THOSE SHOWN ON THE UTILITY RECORD DRAWINGS.THE <br /> CONTRACTOR IS RESPONSIBLE FOR LOCATING AND EXPOSING CONFLICTS <br /> CD �. PRIOR TO CONSTRUCTION. <br /> C) <br /> 0 <br /> o N I I 4. THE LOCATIONS AND DEPTHS OF EXISTING UTILITIES SHOWN ON THESE <br /> co 10 o PLANS ARE APPROXIMATE ONLY.ACTUAL LOCATIONS AND DEPTHS OF <br /> c: L o C3 I UTILITIES MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO <br /> zo in I 10"FS U) o I SWYE 9 CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO <br /> INV 16.28 6"V� LOCATE UTILITY SERVICE LINES AS REQUIRED FOR CONSTRUCTION AND <br /> Z 3 4 o INV 16.28 6"NI NOTIFY THE ENGINEER OF ANY CONFLICTS IMMEDIATELY.ANY DAMAGE BY <br /> NV 16.28 6"EI THE CONTRACTOR TO EXISTING UTILITIES,WHETHER SHOWN ON THE <br /> 10 INV 16.28 6"SI PLANS OR NOT,SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO <br /> "SS I REPAIR,AT HIS EXPENSE. <br /> 9 LF @ <br /> N S=0.0050 <br /> L0m SSC011 <br /> U <br /> 4 8 R�0145 IM 20.01 8 <br /> CD 1 �� INV 16.50 6"E 6 SS <br /> INV 16.29 6" <br /> j 44L = . LF @ <br /> UJI6"SS S=0.0050 / <br /> • 1/2" 10 SSC013 / 8 <br /> 0 <br /> IM 20.0 <br /> INV 16.29 6"S <br /> W INV 16/29 6"N <br /> z SDD17 <br /> o RIM 17.92 I / <br /> TD INV 13.29 15"SW SSC0 16 <br /> mINV 13.29 15"N 24 RIM 21.01 3 4 o D122 15 <br /> ZLO 19.65 <br /> INV 13.29 12"E INV 11J.85 6"S INVM 13.92 12" <br /> g I <br /> m `n � / SSWYE 10 <br /> @ 1 � 22 ❑ o INV 16.65 6" <br /> '1' 0�2� o o M / INV 16.65 6" <br /> w SDDI 16 0 11 EXISTING PROPERTY LINE <br /> > 121LF 12 SD RIM 18.82 15 0 ' INV 16.65 0.S ESDMH <br /> @ S.0 INV 13.02 12"E SDDI 17 o U- 9 " <br /> 0035 15 `n cn = / 6 SS RIM 19. 1 <br /> INV 13.02 12"N RIM 19.50 - 2LF @ I INV 6.4 40"S <br /> d o 0 <br /> J - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - MV,r3.�T2tl� - � 10 / S=0.0050 <br /> - - - - - - - - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INV 6.340"N <br /> PROJECT: 17017 <br /> Q1EU12 SD co SSCO 14 8 F:\17projects\17017 Holly Sugar Industrial\Improvement <br /> N I "FS - - - - 10 _ RIM 21.2 FILE: plans\BUILDINGS H&I\0nsite\17017-052-UTILITY PLAN Il.dwg <br /> M 10"FH 10"FH 10"FH INV 16.6 6 N <br /> Z <br /> RIM 19.06 10 1�2" 1/2" 6"S 1�2„ / I 42"ww I DATE: 1/28/2022 <br /> 1[�LV13Z112"l�L - - - - - - - - - - - - - - - - - - - - - <br /> F - - - - - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -NV17.66 - - - - - - - - - - - 203LF�S�.0�5� - - - - - - - - - - - 1a"ww 1 DRAWN BY: LSF/MWK <br /> cD _ <br /> - - - - - - - - - - - - - - - - - - - <br /> N I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -V <br /> 4L INV 17.666"N I 8"WW <br /> A <br /> VV VY <br /> INV 17.66 6"E <br /> 14I'M SHEET TITLE: <br /> o - - - - - - - - - - - - - - - - - - - - - - - <br /> 11 <br /> 0 - - - - - _ - - - - UTILITY PLAN <br /> _ _ - - - - - ULTIMATE RIGHT OF WAY _ - 21 F � <br /> INV 15 6 <br /> Q , - - S=0.0050 <br /> °H�-=-7ffH OH off OH off EXISTING RIGHT OF WAY SS <br /> 9199 g <br /> 23 <br /> ° <br /> w INV 17.67 6"N k1M 23.6 <br /> � �- � - RIM 6 24"SW <br /> o Know what's below. - - - - - - - - - - - - - - - - L� INV 13.1624"NE01 <br /> Call before you dig. o C52 <br /> ESDCB ARBOR AVENUE ■ <br /> 12 W RIM 18.60 12 W I SCALE: 1"=20' <br /> UNIFORM DRAWING SYSTEM - U.S.NATIONAL CAD STANDARD VERSION 3.1 <br />