My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085267_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ARBOR
>
9409
>
2600 - Land Use Program
>
SR0085267_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2022 2:23:30 PM
Creation date
5/19/2022 2:54:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0085267
PE
2602
STREET_NUMBER
9409
Direction
W
STREET_NAME
ARBOR
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21216020
ENTERED_DATE
5/12/2022 12:00:00 AM
SITE_LOCATION
9409 W ARBOR AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
48"0 TOPP FIBERGLASS SUMP WITH <br /> CRISTY B9 CONCRETE SPLICE BOX WITH B9C ANTIFLOATATION FLANGE AND LIFTING LUGS DANFOSS FLOMATIC MODEL 208S BALL CHECK VALVE(VERTICAL POSITION)WITH ■ <br /> 24"CAST IRON RING & CONCRETE LID OR APPROVED EQUAL. SOCKET WELD ENDS AND BUNA-N BALL. SIZE PER ON FORCE MAIN SIZE. BALL VALVE <br /> COVER WITH GASKET AS REQUIRED ll <br /> (GASTIGHT)STANDARD (AT EXTRA COST) NOTE: 6..L SHUT OFF VALVE WITH UNION ENDS(HORIZONTAL POSITION). <br /> v 1. LIQUID CAPACITY: 5,000 GALLONS. <br /> z - SEE SHEETS C5.1-05.2 FOR 48"O PREMOLDED TOPP NON-SKID <br /> _ " RIM ELEVATION 2. BOX DESIGN LOAD: H-20 TRAFFIC SUMP "FROG MOUTH"FIBERGLASS BASIN <br /> Lu FROM 1'TO 6'OF SOIL COVER. CHAMBER COVER MODEL C48DFA. <br /> � � 2432-03 RISER-3 <br /> Z 2432-06 RISER 6" SEE SHEETS C5.1-05.2 <br /> z v 2432-12 RISER-12" <br /> > LO CONCRETE CLEAN-OUT TO CONTROL PANEL. CONTROL PANEL SHALL HAVE A <br /> �I DO COVERS 24"CLEAR FLOW MONITORING CAPABILITY TO TRACK FLOW DATA. ORENCO G-150 OR G 2 <br /> OPENING, EACH END WATER TIGHT GROMMET. <br /> 16'-11" ORENCO SB WATERPROOF JUNCTION BOX.TYPICAL. S I E G F R I E D <br /> No <br /> PLUG TYPICAL. TOPP MODEL SSFB413 STAINLESS <br /> SEE SHEETS C5.1-05.2-4--_ <br /> SHEETS C5.1-05.2 F STAINLESS STEEL LIFTING CABLE WITH STAINLESS STEEL <br /> FOR INLET ELEVATION �. FOR OUTLET ELEVATION - - - - - - - - - - - - - _ - - - _ EYEBOLT FASTENEDR FLOAT ( ) <br /> TO SUMP CHAMBER AND STAINLESS HIGH WATER ALARM STEEL FLOAT BRACKET WITH 4 3428 Brookside Road <br /> F �� STEEL SHACKLE ON PUMP.TYPICAL. 3/8"CORD GRIPS FO Stockton,California 95219 <br /> T PS SEE DETAIL 2, I I I I SWITCH SUPPORT. 209-943-2021 <br /> THIS SHEET I I I I INTEGRAL FIBERGLASS MOLDED IN BY MANUFACTURER 1.0' TOP Fax: 209-942-0214 <br /> rNE OR TOPP MODEL FB FLEXIBLE ENTRY BOOT. CONERY#2900-B1S1C1 Fax: 2 www.siegfriedeng.com <br /> om <br /> _ S I I I I MERCURY FLOAT SWITCHES <br /> ORENCO I I I I WITH WEIGHT, <br /> FT SERIES - O °? PUMP ON NORMALLY CLOSED <br /> BIOTUBE I I I I ~ PUMP OFF 1.5 2 5 FLOAT SWITCHES SEWER SYSTEM DATA <br /> FILTER. I I I I ZOELLER PUMP SEE <br /> I I I I TABLE 20' FORCE MAIN DESIGN MIN. <br /> a <br /> SEPTIC TANK PUMP PUMP HORSE FORCE Q�oFESsio <br /> TANK BOTTOM. SUMP No TANK MODEL l <br /> SEE C5 1 C5 2 T E E <br /> - d• , .. L _ _ _ _ _ _ _ _ _ _ _ _ _ J--L_ _ _ _ _ _ � TREATMENT MODEL POWER MAIN SIZE <br /> RATE HEAD <br /> LENGTH FLOW PUMP N <br /> T . EQ 8"MIN. c� I� <br /> 12 2.. 4.. c / a rnn <br /> SIDE VIEW TOP VIEW EQ SSPS 1 2295 GAL JENSEN PRECAST CONCRETE ZOELLER 163 1/2 HP 2"/4" 463' 30' 24 GPM 10' W09 3 3� <br /> (CUTAWAY) (COVERS&RISERS REMOVED) 8" MIN. 8" MIN. ANTIFLOATATION FLANGE J, P. \* <br /> #5 @ 12"O.C. EACH WAY 12-MIN. 12"MIN. PER MANUFACTURER SSPS 2 2295 GAL JENSEN PRECAST CONCRETE ZOELLER 163 1/2 HP 2"l4" 576' 30' 24 GPM 10' �9TF CIV�L � <br /> 5/8"0 ANCHOR of CAL <br /> 6 FT DIA. BOLT <br /> ELEVATION DATE SIGNED: 01/28/22 <br /> &LNO <br /> PTIC TANK - 5000 GAL 2 SANITARY SEWER PUMP STATION <br /> SCALE NO SCALE <br /> GEOTECHNICAL FILTER FINISHED GRADE <br /> FABRIC <br /> EL. = 16.75 MIN. <br /> EL. = 16.25 <br /> EL. = 16.08 <br /> EDGE OF LEACHFIELD 2 LAYER <br /> o 0 0 <br /> .. 15.75 <br /> _ <br /> SEE DETAIL 8 ON THIS WASHED DRAIN ROCK 12"LAYER OF CLEAN 1"TO 2112" <br /> FINISHED GRADE SHEET FOR LOCATION WASHED DRAIN ROCK <br /> M <br /> GEOTECHNICAL = 14.75 <br /> FILTER FABRIC 4"PERFORATED LEACH <br /> CHRISTY IRRIGATION BOX LINE SLOPED AT 21N/100FT NATIVE SOIL SHALL BE REMOVED APPROXIMATELY THE GROUNDWATER LEVEL AND REPLACED <br /> TIGHT LINE PERFORATED 2" LAYER OF CLEAN 3/4" SCREW-ON CAP AWAY FROM DISTRIBUTION WITH A WELL-GRADED SAND MEETING THE FOLLOWING GRADE SIZE DISTRIBUTION CURVE <br /> 30'MIN. WASHED DRAIN ROCK BOX CHARACTERISTICS. PARTICLE SIZES D10,D30,D60 CAN BE USED FOR CURVE ANALYSIS.THE <br /> p UNIFORMITY COEFFICIENT(CU)AND THE COEFFICIENT OF CURVATURE(CC)CLASSIFY THE SAND <br /> 2' 4"PERFORATED LEACH AS WELL-GRADED OR POORLY-GRADED.A CU VALUE OF BETWEEN 3.9 AND 6 CLASSIFIES THE <br /> LINE(FLAT)TYPICAL EXTENSION rn SAND AS WELL-GRADED THEREFORE THE VALUE OF CC SHOULD RANGE BETWEEN 1 AND 3.THE <br /> 2"FM 4"PVC TIGHT LINES LENGTH PERCENT PASSING THE#200 SIEVE MUST BE LESS THAN 3%AND CARE SHALL BE TAKEN THAT <br /> 4"PVC TIGHT LINE loe 12"LAYER OF CLEAN 3/4" UNKNOWN THE MATERIAL DELIVERIES ARE CONSISTENT AND NOT"DIRTY".THE LOWER THE PERCENTAGE, <br /> 0 0 0 o THE MORE FAVORABLE THE SAND MATERIAL PROVIDED THE DISTRIBUTION CURVE <br /> WASHED DRAIN ROCK CHARACTERISTICS ARE MET.AS THE BACKFILL SAND IS BROUGHT IN BY LIFTS,THE SAND <br /> 2"SCH.40 LONG SHOULD BE LIGHTLY HYDRO-COMPACTED IN AN ATTEMPT TO REPLICATE NATURAL COMPACTION <br /> 2"X4"REDUCER SOIL EFFLUENT SWEEP <br /> p AND PROMOTE HYDRAULIC CONDUCTIVITY(DARCY'S"K"). <br /> JENSEN D30 o INTERFACE EL. =8.25 p GROUND WATER <br /> 4"PERFORATED LEACH LINE <br /> DISTRIBUTION BOX �I = <br /> TELERSE SPEED _ CONTRACTOR SHALL RIP AND HYDRO COMPACT THE BOTTOM 12"AND HAVE THE SOIL TESTED PHELAN <br /> LEVELERS PLACED z o 0 o FOR COMPACTION AND INFILTRATION PRIOR TO BACKFILLING WITH SAND <br /> ON ALL PIPE ENDS � <br /> TO REGULATE 10 D EVELOPM ENT <br /> DISTRIBUTION EL. 8.25 GROUND WATER <br /> 2"X4"REDUCER CONNECT TO ENDS 450 Newport Center Drive, Suite 230 <br /> = p <br /> OF LATERALS Newport Beach, CA 92660 <br /> 34NO <br /> STRIBUTION BOX 4 C�EANOUT 5 �NO <br /> ILDING H LEACH FIELD LINE <br /> SCALE NOIL <br /> LE SCALE <br /> BUILDINGS H&I <br /> GEOTECHNICAL FILTER FINISHED GRADE HOLLY COMMERCE CENTER <br /> FABRIC <br /> I z EL. = 17.25 MIN. <br /> Q <br /> EL. = 16.75 9375 SUGAR RD <br /> EL. = 16.58 <br /> TRACY, CA 95304 <br /> ACCESS LID 2"LAYER OF CLEAN 1"TO 2 1/2" 0 0 o EL. = 16.25 <br /> CHRISTY IRRIGATION BOX WASHED DRAIN ROCK 12"LAYER OF CLEAN 1"TO 2 1/2" <br /> WASHED DRAIN ROCK <br /> 4"THREADED CAP <br /> MILESTONES: <br /> FINISHED GRADE <br /> . = 15.25 28 JANUARY 2022 <br /> BUILDING DEPARTMENT SUBMITTAL <br /> 4"PERFORATED LEACH <br /> NATIVE SOIL SHALL BE REMOVED APPROXIMATELY THE GROUNDWATER LEVEL AND REPLACED <br /> LINE SLOPED AT 21N/100FT WITH A WELL-GRADED SAND MEETING THE FOLLOWING GRADE SIZE DISTRIBUTION CURVE <br /> AWAY FROM DISTRIBUTION CHARACTERISTICS.PARTICLE SIZES D10,D30,D60 CAN BE USED FOR CURVE ANALYSIS.THE <br /> BOX UNIFORMITY COEFFICIENT(CU)AND THE COEFFICIENT OF CURVATURE(CC)CLASSIFY THE SAND <br /> AS WELL-GRADED OR POORLY-GRADED.A CU VALUE OF BETWEEN 3.9 AND 6 CLASSIFIES THE <br /> 4"SCH 40 PVC PIPE SAND AS WELL-GRADED THEREFORE THE VALUE OF CC SHOULD RANGE BETWEEN 1 AND 3.THE <br /> WRAP ENDS(2)WITH FILTER I` PERCENT PASSING THE#200 SIEVE MUST BE LESS THAN 3%AND CARE SHALL BE TAKEN THAT <br /> FABRIC OVER NON-METALIC THE MATERIAL DELIVERIES ARE CONSISTENT AND NOT"DIRTY".THE LOWER THE PERCENTAGE, <br /> 1/8"SCREEN.SECURE WITH THE MORE FAVORABLE THE SAND MATERIAL PROVIDED THE DISTRIBUTION CURVE <br /> ZIP TIE OR EQUIVALENT CHARACTERISTICS ARE MET.AS THE BACKFILL SAND IS BROUGHT IN BY LIFTS,THE SAND <br /> 4"MIN.TYP. 4"MIN.TYP. SHOULD BE LIGHTLY HYDRO-COMPACTED IN AN ATTEMPT TO REPLICATE NATURAL COMPACTION REVISIONS: <br /> AND PROMOTE HYDRAULIC CONDUCTIVITY(DARCY'S"K"). <br /> EL. =8.25 p GROUND WATER <br /> 12"MIN. <br /> CONTRACTOR SHALL RIP AND HYDRO COMPACT THE BOTTOM 12"AND HAVE THE SOIL TESTED <br /> FOR COMPACTION AND INFILTRATION PRIOR TO BACKFILLING WITH SAND <br /> CD <br /> 6 INSPECTION TUBE 7 BUILDING I LEACH FIELD LINE <br /> NO SCALE NO SCALE <br /> V) <br /> J <br /> W <br /> LU <br /> N L <br /> CLEAN OUT 4 LEACH FIELD 7 <br /> I <br /> TYP. _ LINE,TYP.I - PROPERTY LINE <br /> CD <br /> PROPERTY LEACH FIELD 5 CLEAN OUT 4 <br /> j LINE o 0 0 0 0 LINE, TYP. TYP. <br /> W <br /> Z - - - - - - - - - - - - - - - - - <br /> IN6FEU <br /> ION <br /> UBE <br /> SSDB 1 OUTLET INV 15.75 4"E _ - - 4"SS SSCO \ SSCO <br /> r - - - - - - - - - - - - - - - - INV16_254W <br /> - - - - - - - INV 15.644"W I INV 16.144E 4 S <br /> N INV 15.91 4 W S=0.0016 @ 70LF PERF I I - - - - - - �- <br /> z SSDB 1 SS INSPECTION TUBE SSCO I SSCO @ SS INSPECTION TUBE <br /> S=0.0016 70LF PERF <br /> o I INV 16.08 4"W INV 15.75 4 E _ - - 4"SS - - - - - - - INV 15.64 4 W I I INV 16.14 4"E 4"SS INV_16.25 4"W - _ ��0000 <br /> j 2"SSFM - S=0.0016 @ 70LF PERF I I S-0.0016 @ 70LF PERF SSDB 1 OUTLET 30'MIN <br /> SS INSPECTION TUBE I - INV 16.42 4"N <br /> N 14LF @ S-0.0000 INV 15.75 4"E _ - - I SS INSPECTION TUBE 4"SSFM � <br /> Z 32LF @ S=0.0000 4'SS - - - - - - - 100%RESERVE AREA(3,500SF) I I 100% RESERVE AREA(3,500SF)�` - - - - - - - 4"SS INV 16_25 4"W _ _ INV 16.58 6 58 4"E 2"X4"REDUCER <br /> � I 4"SSFM S=0.0016 @ 70LF PERF SSCO I SSCO S=0.0016 @ 70LF PERF <br /> SS INSPECTION TUBE INV 15.64 4"W I \ <br /> z INV 15.75 4"E - - - I INV 16.14 4"E SS INSPECTION TUBE 4"SSFM 2"SSFM <br /> 2X4 - 4"SS - - - - - - - I I 4, S INV 16.25 4"W _ _ 6LF @ S=0.0000 47LF @ S=0.0000 <br /> � REDUCER S=0.0016 @ 70LF PERF SSCO <br /> ERF <br /> > SS INSPECTION TUBE INV 15.64 4"W I \ . I INV 16.14 6.14 4"E S-0.0016 @ 70LF SS INSPECTION TUBE <br /> 30'MIN 4"SSFM INV 15.75 4"E _ - - 4"SS - - - - - - - SSCO I I 4"SS INV 16.25 4"W - <br /> S=0.0016 @ 70LF PERF INV 15.64 4"W \ I SSCO - - - - - - - � - - - - - 3 DISTRIBUTION <br /> J <br /> - - - - - - - - - - - - - INV 16.144"E S=0.0016 @ 70LF PERFBOX PROJECT: 17017 <br /> g I DISTRIBUTION 3 <br /> ry <br /> F:\17projects\17017 Holly Sugar Industrial\Improvement <br /> o BOX <br /> FILE: plans\BUILDINGS H&I\Onsite\17017-C7.2 DETAILS Ill.dwg <br /> SSDB 1 OUTLET <br /> z I o0o SSDB 1 OUTLET \ <br /> ! � INV 15.91 4"W 6 INSPECTION INV 16.42 4"S DATE: 1/28/2022 <br /> C I @��� TUBE,TYP. DRAWN BY: LSF/MWK <br /> M I �� `� <br /> 6 INSPECTION <br /> TUBE,TYP. THE SEPTIC SYSTEM SHALL BE CONSTRUCTED SHEET TITLE: <br /> I BY AN EXPERIENCED SEPTIC SYSTEM DETAILS III <br /> \ CONTRACTOR WITH AT LEAST 10 YEARS OF <br /> SEPTIC INSTALLATION EXPERIENCE. <br /> C) <br /> FILTER BED <br /> 0 <br /> r SCALE: 1"=20' C7m2 <br /> UNIFORM DRAWING SYSTEM - U.S.NATIONAL CAD STANDARD VERSION 3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.