Laserfiche WebLink
A5 TURBINE ACCESS 18" TYP 37 TURBINE ACCESS 18" TYP 18" TYP. TURBINE ACCESS 37 THICKENED SLAB <br /> THICKENED SLAB 37 MANHOLE THICKENED SLAB MANHOLE MANHOLE <br /> SEE NOTE #4 MIN. 2" CROWN SEE NOTE #4 MIN. 2" CROWN 2" CROWN MIN. SEE NOTE #4 <br /> SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 p p Z <br /> D O J <br /> O co 00 <br /> O 44 d ad O O 44 d 44 D _ .4 4 <br /> D <br /> p 4 p 4 D d <br /> 4 4 W /r r <br /> TANK LEVEL MONITOR TANK LEVEL MONITOR TANK LEVEL MONITOR 51 48 47 + Q O <br /> 2" 0-30HG 47 48 51 W/ MONITORING CAP 47 <br /> �4�8W/ MONITORING CAP W/ MONITORING CAP o Z � J <br /> LIQUID-FILLED GAUGE AND ADAPTER AND ADAPTER AND ADAPTER (L O WCOV <br /> 1/2" 90° ELBOW 150# S.S. FACE SEAL ADAPTER (TYP.) FACE SEAL ADAPTER (TYP.) FACE SEAL ADAPTER (TYP.) z =) Z L <br /> 3/8" COPPER TUBING TO " SUMP FLAME ARRESTOR 63 ° o U) <br /> o 63 SUMP FLAME ARRESTOR 3 EZ-FIT 90 63 SUMP FLAME ARRESTOR g 8 Q J J W <br /> SIPHON CHECK VALVE 201 H J Q Z <br /> 0 „ „ DEGREE ELBOW (TYP.) 3"x18" FLEXIBLE CONNECTOR W/ � Z Q Z U — <br /> 44 3x18 FLEXIBLE CONNECTOR W/ (L4� 3"x`18" FLEXIBLE CONNECTOR W/ 44 N JEZ-FIT MALE X EX FLANGE FIBER GLASSEZ-FIT MALE X EX FLANGE EZ-FIT MALE X EX FLANGE LLJ <br /> " SYSTEMS 4" OVER 125 116 FIBER GLASS o M �3 EZ-FIT 90 FIBER GLASS OFIBER GLASS �, U cn <br /> 201 116 125 " 3" FRP SIPHON - 116 125 " SYSTEMS 4" OVER 125 116 201 3 EZ-FIT 90 � �„ N Z Z � Q Q <br /> DEGREE ELBOW (TYP.) _ SYSTEMS 4 OVER SYSTEMS 4 OVER _ _ DEGREE ELBOW (TYP.) v) o Q <br /> - - 3" FRP SIPHON PIPING TO TANK#1 - - - - 3" FRP SIPHON 3 FRP SIPHON < <br /> PIPING TO TANK#2 PIPING TO TANK#3 PIPING TO TANK#2 3" EZ-FIT X MALE Z 0 O <br /> 3 EZ-FIT X MALE 3 EZ-FIT X MALE 203 4" FRP BONDED 4" FRP BONDED 75 203 HEX ADAPTER (TYP.) V) Cn � Q N V <br /> HEX ADAPTER (TYP.) 203 I 75 4" FRP BONDED HEX ADAPTER (TYP.) o� 75 FITTING TYP. 1 V C4 <br /> FITTING (TYP.) — FITTING (TYP.) ( ) SUMP SENSOR IN > > > co <br /> SUMP SENSOR IN HOLDER 31 °'� 3" FRP "PRIMARY" SUMP SENSOR IN HOLDER 31 X. M <br /> 3" FRP "PRIMARY" 3" FRP "PRIMARY" 118 ��� 31 HOLDER SEE NOTE 3 0 0 0 Z O O <br /> (SEE NOTE #3) 118 ELBOW (TYP.) (SEE NOTE #3) 118 ELBOW (TYP.) ELBOW (TYP.) ( # ) o 0 o T Q Q V <br /> 48" DW V8-SIDED FIBERGLASS 4 I 48" DW V8-SIDED FIBERGLASS 4 I " 3" EZ-FIT X FEMALE GLUE I m m m m <br /> CONTAINMENT SUMP 204 3 EZ-FIT X FEMALE GLUE CONTAINMENT SUMP 204 3 EZ-FIT X FEMALE GLUE PIPE FOR FIBERGLASS PIPING 204 O F48" DW BERGLAS8-SIDED -74 N <br /> PIPE FOR FIBERGLASS PIPING PIPE FOR FIBERGLASS PIPING N <br /> EXISTING TANK 200 3EZ-FIT CLAMP W/ - <br /> " 3 EZ-FIT CLAMP W/ 200 CONTAINMENT SUMP <br /> EXISTING TANK 3" EZ-FIT CLAMP W/ o <br /> EXISTING <T- <br /> 4%3" <br /> TOP TO REMAIN 200 VITON SEAL (TYP.) TOP TO REMAIN VITON SEAL (TYP.) VITON SEAL (TYP.) TANK �, �TOP TO REMAIN DOUBLE TAPPED BUSHING 52 4" RISER SCH. 40 STAINLESS 4"x3" DOUBLE TAPPED BUSHING 52 4" RISER SCH. 40 STAINLESS 4" RISER SCH. 40 STAINLESS 52 4"x3" DOUBLE TAPPED BUSHING <br /> STEEL, (WRAPPED) <br /> STEEL, (WRAPPED) STEEL, (WRAPPED) <br /> 3" STAINLESS STEEL SIPHON STINGER. 62 3" BALL VALVE 3" STAINLESS STEEL SIPHON STINGER. 62 3" BALL VALVE 3" BALL VALVE 62 3" STAINLESS STEEL SIPHON STINGER. <br /> TERMINATE 6" FROM BOTTOM OF TANK TERMINATE 6" FROM BOTTOM OF TANK 11 11 TERMINATE 6" FROM BOTTOM OF TANK <br /> NOTE: TOP OF SIPHON PIPING SHALL BE 4124"X1/4" THICK STRIKER PLATE NOTE: TOP OF SIPHON PIPING SHALL BE 4124"X1/4" THICK STRIKER PLATE 24"X1/4" THICK STRIKER PLATE NOTE: TOP OF SIPHON PIPING SHALL BE <br /> INSTALLED LEVEL AND NO HIGHER THAN 145" UNDER ALL OPENINGS BY TANK INSTALLED LEVEL AND NO HIGHER THAN 145" UNDER ALL OPENINGS BY TANK UNDER ALL OPENINGS BY TANK INSTALLED LEVEL AND NO HIGHER THAN 145" <br /> FROM BOTTOM OF TANK ON BOTH TANKS. MANUFACTURER (TYP.) FROM BOTTOM OF TANK ON BOTH TANKS. MANUFACTURER (TYP.) MANUFACTURER (TYP.) FROM BOTTOM OF TANK ON BOTH TANKS. <br /> A <br /> Siphon Piping at Tank #1 B Siphon Piping at Tank #2 c Siphon Piping at Tank #3 <br /> T4-2 SCALE: 1 "=V-0"'-0" T4-2 SCALE: 1 "=V-0"'-o" <br /> T4-2 SCALE: 11 "=V-0" <br /> 34" Lid O.D. W <br /> MINI HYDROSTATIC 26 J 0404 <br /> SENSOR 32-3/4" Neck O.D. Q W O <br /> FACTORY SUPPLIED 2 WIRE SHIELDED CABLE W O <br /> SUMP RESERVOIR MANOMETER & _j0 Q <br /> 30" I.D. HDPE TUBING TO W <br /> SUMP TEST PORT FOR <br /> CONTINUITY TESTING SUMP Q I <br /> 0j <br /> ROUND BODY H 0) O <br /> SLIP ON RISER O EXTENSION <br /> FIELD SEALED JOINT. 48 I.D. YO x 12" LONG FIBERGLASS PIPE BONDED V <br /> 4" BALL VALVE W/ BARB FITTING AT (ADHESIVE SUPPLIED TO SUMP INNER WALL USING GASOLINE <br /> FACTORY INSTALLED BUSHING W/ KIT) J Ln COMPATIBLE EPDXY RESIN. SUMP SENSOR IN HOLDER <br /> °�� <br /> � � � 31 (SEE NOTE #3) <br /> CONTRACTOR TO INSTALL GALVANIZED METAL <br /> OR FIBERGLASS SPACER TO ALLOW FIBERGLASS <br /> FACTORY <br /> 3/8 X 1/4 SS BUSHING LAY-UP N PIPE TO CLEAR SUMP COLLAR "LIP". °7 LL <br /> INSTALLED AT FACTORY APEX OF FIBERGLASS CONTRACTOR TO USE GASOLINE-COMPATIBLE <br /> TANK COLLAR BONDED EPDXY TO BOND SPACER TO SUMP. APEX OF FIBERGLASS <br /> TO TANK CONTRACTOR MAY USE UNISTRUT, FIBERGLASS p7� TANK <br /> PIPE, OR ANY OTHER EQUIVALENT MATERIAL <br /> 48" DIA. POLYGON SUMP BODY THAT CAN WITHSTAND ENVIRONMENT OF SUMP <br /> (8-20"X 19" FLAT PANELS) TO SECURE THE SUMP SENSOR SO THAT IT <br /> CAN BE REMOVED FOR INSPECTION AND <br /> RESECURED WITHIN THE SUMP <br /> JOINT DETAILS 1/4" DRAIN/TEST BUSHING. <br /> FACTORY INSTALLED <br /> O CONTRACTOR TO ADDITIONALLY GLASS WRAP & LAMINATE AT *NOTE: <br /> CONNECTION FOLLOWING CURING OF ADHESIVE. SPECIFIC ATTENTION CONTRACTOR SHALL BE HELD RESPONSIBLE FOR PROPER <br /> MUST BE GIVEN TO SURFACE PREP AS TESTING REQUIREMENTS WILL INSTALLATION & PREPARATION PER MANUFACTURERS <br /> DETECT THE SMALLEST OF FLAWS. ALL MATERIALS MUST BE INSTRUCTIONS AND SHALL REINSTALL SUMPS IF <br /> ESSIpHq <br /> COMPATIBLE WITH GASOLINE, GASOLINE WITH 15% METHANOL AND HYDROSTATIC TESTING SHOWS LEAKING IN THIS AREA OF QRpf <br /> 10% ETHANOL. FIBERGLASS AND RESIN MUST EXTEND 1/2" BEYOND THE SUMP. TESTING OF SUMP SHALL BE PERFORMED =��� 61 <br /> Tank Sump Drain Port Detail (Typ. Fill + Turbine Sumps) COVERAGE OF ADHESIVE. AFTER REDUCER IS INSTALLED. HAL P. GRUBS ri <br /> T4-2 SCALE: 1 "=l '-O" E Double Wall Sump Installation Detail at Tank #1-3 F SensorHolder Detail J 67814 70 <br /> ��-2SCALE: 1 "=V-0" (Turbine SumpOnly) T4-2 SCALE: 2"= 1 '-0" s� / v \- ��1ofC F `,Fo <br /> CA 05/27/22 <br /> i <br /> i <br /> Sheet Notes <br /> o a a <br /> 00 L4 <br /> z ami z X <br /> 1 • - PIPE & CONDUIT PENETRATIONS: N o <br /> ALL PENETRATIONS OF THE TANK SUMPS SHALL BE SEALED WITH DOUBLE BULKHEAD FITTINGS SHALL BE INSTALLED PERPENDICULAR <br /> TO SUMP WALL TO ENSURE THE PROPER INSTALLATION OF ALL BULKHEAD FITTINGS AND RESULTANT WATER TIGHTNESS. ALL PIPING, N <br /> CONDUIT AND GROUNDS THAT PENETRATE THE SUMP SIDE WALLS MUST BE SEALED IN SUMPS. SUMPS SHALL BE HYDROSTATICALLY m <br /> TESTED WITH STANDING WATER FOR A PERIOD OF 24 HOURS TO INSURE THAT THE SUMPS ARE WATERTIGHT. <br /> 2. - PIPING TESTING: c Y n <br /> O� 3 �, 0 U <br /> fn p N d �+ (n <br /> 0 0 a o <br /> TESTING OF THE SECONDARY CONTAINMENT PIPING IS REQUIRED. THE CONTAINMENT TERMINATION FITTING IN THE SUMP IS TO BE <br /> INSTALLED WITH THE VALVE TURNED DOWN. THE PIPING IS TO BE CONTINUOUSLY MONITORED BY VACUUM, PRESSURE OR co <br /> HYDROSTATIC. THEREFORE THE VALVE UNLESS BEING TESTED SHOULD REMAIN CLOSED. <br /> V <br /> 3. - SUMP SENSORS: O <br /> SENSOR TO BE MOUNTED AT SIDE OF TANK WHERE PRODUCT PENETRATION INTO SUMP IS MADE AND BELOW LOWEST PENETRATION — v � <br /> FITTING WITHIN SUMP AREA. MOUNT SENSOR FLUSH TO LOWEST POINT IN SUMP BOTTOM. ALL TANK SUMP SENSORS SHALL BE Vj W N <br /> NON-DISCRIMINATING AND POSITION SENSITIVE. Lw 0 <br /> 4. - MANHOLE CROWNS: 4) M <br /> ALL MANHOLE OPENINGS ON THE TANK SLAB SHALL BE INSTALLED WITH A 2" X 18" RUN CROWN OF CONCRETE TO PREVENT WATER .� �o o <br /> INTRUSION INTO THE MANHOLE. M <br /> 5. - U.G. CONDUIT: <br /> ALL U.G. CONDUIT TO TANK SUMPS SHALL BE ROBROY RIGID STEEL PVC COATED SCHEDULE 40 (NO SUBSTITUTIONS). CONDUIT M <br /> MINIMUM BURY DEPTH IS 24" PER CODE. ALL JUNCTION BOXES SHALL BE CLASS 1 DIV. 2 RATED. ALL ELECTRICAL CONDUIT IN .� Q rn N <br /> SUMPS SHALL INCLUDE A SEAL-OFF ENTERING AND LEAVING. SEAL-OFFS SHALL BE INSTALLED 6 MIN. ABOVE HIGHEST +.+ N <br /> PENETRATION IN SUMP. <br /> Q � <br /> :3 <br /> 6. STAINLESS STEEL FITTINGS: <br /> � U', <br /> Lun }T N U <br /> CONTRACTOR TO PROVIDE ALL MISCELLANEOUS NPT FITTINGS AND NIPPLES FOR CONNECTIONS TO TURBINES, SIPHON SYSTEM m V 00r Y un L <br /> AND VAPOR RECOVERY SYSTEM. ALL STAINLESS STEEL FITTINGS SHALL BE MANUFACTURED BY "STANDARD PIPE PRODUCTS" <br /> OR EQUAL SPECIFICATIONS AS FOLLOWS: <br /> 0 <br /> S.S. FITTINGS <br /> DIMENSIONS MATERIAL THREAD PRESSURE RATING <br /> (TEES, ELBOWS) w <br /> CLASS 150/PN 20 ASME B16.3 ASTM A-182 ASME B.1 20.1 ASME B16.3 0 <br /> N <br /> S.S. UNIONS <br /> CLASS 150/PN 20 ASME B16.39 ASTM A-182 ASME B.1 20.1 ASME B16.3 <br /> S.S. PIPE <br /> CLASS 150/PN 20 ASTM A733 ASTM A-312 ASME B.1 20.1 ASME B16.3 i <br /> 0 <br /> Ln <br /> 0 <br /> CD <br /> 7. - CORROSION PROOF: <br /> G Not Used (�_H� Not Used ALL TURBINE PUMP HEADS TO HAVE ADVANCED CORROSION PROOF PROTECTION WITH E-COATED FINISH. Ln N <br /> or CD <br /> T4-2 SCALE: NONE T4-2 SCALE: NONE -.0 N <br />