My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> REMOVE EXISTING 4" OVER 3" FRP PIPING (TYP.) REMOVE EXISTING 4 x3 CONTAINMENT EXISTING 22" MANWAY PLATE COVER TO REMAIN <br /> I I TERMINATION FITTING W/ TEST PORT (TYP.) 110 116 3" OVER 2" FRP ADDITIVE <br /> 00 <br /> REMOVE EXISTING 4" SUMP PENETRATION FITTING. I I REMOVE EXISTING 3" BELL x 3/4" X 15" FLEXIBLE CONNECTOR 45 PIPING (TYP.) (n � <br /> PATCH BACK SUMP WALL AS REQUIRED (TYP.) I i MALE ADAPTER (TYP.) 72 3" BONDED FITTING (TYP.) J � � <br /> REMOVE EXISTING PIPING RETROFIT PENETRATION EXISTING EXPLOSION PROOF 3 EZ-FIT CLAMP W/ 200 EXISTING EXPLOSION PROOF H Q <br /> JUNCTION BOX TO REMAIN VITON SEAL TYP. <br /> FITTING FOR DOUBLE WALL SUMP (TYP.) � (TYP.) � JUNCTION BOX TO REMAIN <br /> EXISTING ENTRY BOOT TO REMAIN 3" EZ-FIT 90 DEGREE o D Q Ir I J <br /> 201 EXISTING ENTRY BOOT TO REMAIN D U <br /> EXISTING 22 MANWAY PLATE COVER TO REMAIN ° EXISTING ENTRY BOOT TO REMAIN ELBOW (TYP.) CIOJ Z Z � Q <br /> REMOVE EXISTING 3/4" FLEX CONNECTOR (TYP.) .10 I° 3" EZ-FIT X MALE HEX ADAPTER TYP. 203 EXISTING ENTRY BOOT TO REMAIN <br /> (TYP.) z J � J � LL <br /> C) <br /> REMOVE EXISTING FILL SPILL BUCKET, SWIVEL FILL EXISTING SPLIT CONDUIT RETROFIT — EXISTING SPLIT CONDUIT RETROFIT � LL Q Q W <br /> ADAPTER & MORRISON BROTHERS CAP (TYP.) °�°—° ° PENETRATION FITTING FOR DOUBLE 4"x4"x3"x2" EXTRACTOR CROSS FITTING 22 ° ° PENETRATION FITTING FOR DOUBLE J Z U Z <br /> REMOVE EXISTING SUMP FLAME ARRESTOR. ° - WALL SUMP TO REMAIN WALL SUMP TO REMAIN N Z J Q J <br /> REINSTALL EXISTING SUMPw Q O <br /> SAVE FOR RE-INSTALLATION (TYP.) ° EXISTING 48 DIA. OUTER ° EXISTING 48 0-DIA. OUTER - <br /> ® \ .) 1 SUMP WALL TO REMAIN o <br /> FLAME ARRESTOR (TYP ) (.5Q co <br /> I SUMP WALL TO REMAIN <br /> REMOVE EXISTING TANK ID MARKER (TYP.)_l_.__oO OI EXISTING INNER SUMP 12 O EXISTING INNER SUMP o o <br /> I CI_< 0 Z <br /> REMOVE EXISTING BRAVO BONDED ° WALL TO REMAIN WALL TO REMAIN � ; a_ Z — o <br /> ° REMOVE EXISTING VAPOR SPILL 2 EZ-FIT X MALE ° ° (;j `p O <br /> PENETRATION FITTING. PATCH BACK SUMP 203 2 EZ-FIT X FEMALE GLUE CD CD <br /> _ _ _ U <br /> BUCKET, SWIVEL VAPOR HEX ADAPTER (TYP.) 204 � � � a � <br /> WALL AS REQUIRED (TYP.) PIPE FOR FIBERGLASS PIPING <br /> REMOVE EXISTING 3 4" CONDUIT LOOP ° ° ADAPTER & MORRISON 2" EZ-FIT 90 DEGREE 201 > > > Q W � co <br /> TO OTHER GASOLINE TANKS TYP. BROTHERS CAP (TYP.) ELBOW (TYP.) S O <br /> (TYP.) 3 BONDED FITTING (TYP.) o 0 o Y Q <br /> � NEW SEAL-OFF AND EXPLOSION 3" EZ-FIT X FEMALE GLUE 204 \� � m m m m U <br /> REMOVE EXISTING BONDED PASS-THRU PIPE i PROOF J-BOX (TYP.) Z <br /> PENETRATION FITTING. PATCH BACK SUMP PIPE FOR FIBERGLASS PIPING i �, Q <br /> i REMOVE EXISTING 3 FLEX �� i 3" OVER 2" FRP VENTC4 -74 <br /> N C'14 <br /> 0 <br /> WALL AS REQUIRED. TYP. CONNECTOR (TYP.) 4 BONDED FITTING (TYP.) 77 110 116 No <br /> i PIPING (TYP.) <br /> REMOVE EXISTING 3" OVER 2" EXISTING SUMP SENSOR TO REMAIN (TYP.) ' o <br /> DOUBLE WALL FIBERGLASS 4" OVER 3" FRP VAPOR 116 125 200 2" EZ-FIT CLAMP W/ VITON Z <br /> PRODUCT PIPING FROM ADDITIVE REMOVE EXISTING 2" X 3/4" BELL REDUCER (TYP.) RECOVERY PIPING (TYP.) SEAL (TYP.) <br /> TANK. REMOVE 2" FRP BELL X MALE ADAPTOR (TYP.) EXISTING SUMP SENSOR TO REMAIN (TYP.) 49 2"x12" FLEXIBLE CONNECTOR W/ EZ-FIT MALE X EX <br /> REMOVE 2"X3" FRP REDUCER (TYP.) FLANGE (SEE NOTE #10) <br /> 50 3"x12" FLEXIBLE CONNECTOR W/ EZ-FIT <br /> MALE X EZ-FIT FLANGE (SEE NOTE #10) <br /> A Existing Fill Sump and Hydrostatic Reservoir Plan View a Tanks 1-3 Only c Prop08ed Fill Sump and Hydrostatic Reservoir Plan View a Tanks #1-3 Only (�_E NOT USED <br /> T5-1 SCALE: 1 "= 1 '-o" T5-1 SCALE: 1 "=1 '-O" <br /> T5-3 SCALE: NONE <br /> REMOVE EXISTING SWIVEL VAPOR ADAPTER & REMOVE NEW CSI WATER TIGHT SUMP SWIVEL VAPOR ADAPTERge <br /> MORRISON BROTHERS CAP (TYP.) SHIELD ASSEMBLY (TYP.) & CAP (TYP.) 10 DUAL POINT FILL - SPILL CONTAINMENT MANHOLE <br /> REMOVE EXISTING DUAL POINT FILL - SPILL CONTAINMENT REMOVE EXISTING SWIVEL FILL ADAPTER MAINTAIN 5" MIN. 6" MAX. CLEARANCE BETWEEN W/ 5 GALLON SPILL BUCKETS <br /> MANHOLE W/ (2) 5 GALLON SPILL BUCKETS (TYP.) & MORRISON BROTHERS CAP (TYP.) TOP OF CAP AND GRADE. (SEE NOTE #4) 18„ 10" ABSOLUTE MIN. W <br /> REMOVE EXISTING TANK ID MARKER (TYP.) REMOVE EXISTING 4 PIPE NIPPLE (TYP.) 4" PRODUCT I.D. TAG. DISTANCE TO TOP EDGE OF J N <br /> op <br /> REMOVE EXISTING SHROUD BOOTS RECESSED FLUSH W/ CONC. 12 MIN. TYP. SUMP NECK Q W O <br /> REMOVE EXISITNG (TYP.) (TYP.) 2" CROWN SEE W ] OD <br /> CONCRETE SLAB (TYP.) 4 <br /> a a a ° d v <br /> NOTE 6 J Q <br /> a° a L - a a � O D <br /> a a a z <br /> 4 a . . a00 <br /> a s �. Q a 4 a ate. Q a 2 W <br /> A 2 . i <br /> EXISTING MINI HYDROSTATIC SUMP aa a , <br /> � Q = <br /> SENSOR TO REMAIN a a FILL SIDE SUMP 5 I O J Q <br /> EXISTING 2-IN-1 SENSOR BOX TO REMAIN REMOVE EXISTING CSI DOUBLE W REDUCER 14 13 SWIVEL FILL ADAPTER N O <br /> WALL SUMP TOPHAT REDUCER STEEL RING - & CAP (TYP.) U O <br /> REMOVE EXISTING BONDED PASS-THRU � -� � 1 O Q <br /> PIPE PENETRATION FITTING. PATCH BACK (TYP.) 0 FACE SEAL ADAPTER (TYP.) ^` O O (n <br /> SUMP WALL AS REQUIRED. (TYP.) ° o REMOVE EXISTING SEAL-OFFS `�' FIELD-CUT LENGTH ° U <br /> REMOVE EXISTING 3" OVER 2" DOUBLE AND EXPLOSION PROOF Q AS NEEDED ( NIPPLE O (2) 1 & RE 4 GND CLAMPS <br /> WALL FIBERGLASS PRODUCT PIPING J-BOX ) W/ 6 BARE SOLID <br /> - - - - (BY G.C.) - - <br /> FROM ADDITIVE TANK (TYP.) _ _ _ COUPLER (BY G.C.) - - <br /> REMOVE EXISTING 3/4" CONDUIT LOOP EXISTING SPLIT CONDUIT RETROFIT G ADDITIVE PIPE <br /> TO OTHER GASOLINE TANKS (TYP.) PENETRATION FITTING FOR DOUBLE REINSTALL EXISTING SUMP T5-1 CONNECTION <br /> REMOVE EXISTING BRAVO BONDED I I � WALL SUMP TO REMAIN ° e <br /> REMOVE EXISTING 3/4 SOLENOID FLAME ARRESTOR (TYP.) EXISTING SPLIT CONDUIT RETROFIT <br /> LL <br /> PENETRATION FITTING. PATCH BACK VALVE (TYP.) 4" S.S. IRON RISERS SEE NOTE 9 PENETRATION FITTING FOR DOUBLE <br /> SUMP WALL AS REQUIRED (TYP.) + REMOVE EXISTING 3/4" "Y" ( # ) + WALL SUMP TO REMAIN <br /> REMOVE EXISTING 2"X3" FRP REDUCER (TYP.) O O <br /> STRAINER (TYP.) <br /> REMOVE EXISTING 2" X 3/4" BELL AREMOVE EXISTING 6"X4" <br /> REDUCER (TYP.) BUSHING (TYP.) EXISTING 22" MANWAY PLATE <br /> EXISTING TANK TOP (TYP.) o EXISTING TANK TOP (TYP.) <br /> EXISTING 22 MANWAY COVER TO REMAIN <br /> PLATE COVER TO <br /> REMOVE EXISTING 3/4" 3-WAY BALL _ REMAIN _ e <br /> VALVE W/ PLUG (TYP. 2) EXISTING 2"X3/4" BUSHING TO REMAIN EXISTING 2"X3/4" BUSHING TO REMAIN <br /> REMOVE EXISTING 3/4" FLEX 4"x4"x2"X3" EXTRACTOR 22 DROP TUBE W/ OVERFILL PREVENTION15 <br /> CONNECTOR (TYP.) REMOVE EXISTING FILL DROP FITTING (TYP.) VALVE SET @ 95% CAPACITY. TERMINATE <br /> REMOVE EXISTING 3/4" 3-WAY BALL TUBE (TYP.) DROP TUBE MIN. 4", MAX. 6" ABOVE <br /> VALVE W/ PLUG (TYP. 2) EXISTING SUMP SENSOR TO EXISTING SUMP SENSOR TO STRIKER PLATE (TYP. SEE NOTE #5) <br /> QRpfESSIpHq� <br /> REMOVE EXISTING "OPW" BALL FLOAT REMAIN (TYP.) REMAIN (TYP.) 45° ��o �ti61 <br /> VALVE SET (TYP.) NEW 3/4" STAINLESS STEEL 4" TO 6" MAX. �= HAL P. GRUBB <br /> REMOVE EXISTING 3/4 BLACK IRON PIPING STINGER (TYP.) J 67814 70 <br /> PIPING STINGER (TYP.) <br /> rB_"� ExistingFill SumpInstallation Detail � Tanks #1-3 Only F NOT USED `�-9T � � � � � Fo� PD Proposed Fill Sump Installation Detail � Tanks Only _ °F �A`� 05/27/22 <br /> T5-1 SCALE: 1 "=1 '-0" T5 3 SCALE. NONE <br /> T5-1 SCALE: 1 "=1 '—O" <br /> heet Notes ° Q U Q <br /> S U = Z j Z X <br /> N <br /> O <br /> c� <br /> 1 . - PIPE & CONDUIT PENETRATIONS: °° <br /> ALL PENETRATIONS OF THE TANK SUMPS SHALL BE SEALED WITH DOUBLE BULKHEAD FITTINGS SHALL BE INSTALLED PERPENDICULAR TO SUMP WALL TO ENSURE THE PROPER INSTALLATION OF ALL BULKHEAD FITTINGS AND RESULTANT WATER TIGHTNESS. ALL PIPING, 0 0 0 N <br /> CONDUIT AND GROUNDS THAT PENETRATE THE SUMP SIDE WALLS MUST BE SEALED IN SUMPS. SUMPS SHALL BE HYDROSTATICALLY TESTED WITH STANDING WATER FOR A PERIOD OF 24 HOURS TO INSURE THAT THE SUMPS ARE WATERTIGHT. m <br /> 2. - PIPING TESTING: <br /> cnY <br /> TESTING OF THE SECONDARY CONTAINMENT PIPING IS REQUIRED. THE CONTAINMENT TERMINATION FITTING IN THE SUMP IS TO BE INSTALLED WITH THE VALVE TURNED DOWN. THE PIPING IS TO BE CONTINUOUSLY MONITORED BY VACUUM, PRESSURE OR a <br /> 0 0 � a o <br /> HYDROSTATIC. THEREFORE THE VALVE UNLESS BEING TESTED SHOULD REMAIN CLOSED. <br /> 3. - SUMP SENSORS: <br /> SENSOR TO BE MOUNTED AT SIDE OF TANK WHERE VENT/VAPOR PIPING PENETRATES INTO THE SUMP IS MADE AND BELOW LOWEST PENETRATION FITTING WITHIN SUMP AREA. MOUNT SENSOR FLUSH <br /> Ln <br /> TO LOWEST POINT IN SUMP BOTTOM. ALL TANK SUMP SENSORS SHALL BE NON-DISCRIMINATING AND POSITION SENSITIVE. p o <br /> 4. - FILL AND VAPOR CAP HEIGHT TO GRADE: — v <br /> THIS DIMENSION IS CRITICAL AND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. i N <br /> 5. - DROP TUBE CRITICAL DIMENSION: <br /> THIS DIMENSION IS CRITICAL AND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. 1 m <br /> 1 15 2 BELL X MALE ADAPTER (TYP.) <br /> 6. - MANHOLE CROWNS: O i <br /> ALL MANHOLE OPENINGS ON THE TANK SLAB SHALL BE INSTALLED WITH A 2" X 18" RUN CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. 72 3" BONDED FITTING (TYP.) N m <br /> 7. - U.G. CONDUIT: <br /> EXISTING 48" SUMP (TYP.) W N M <br /> ALL U.G. CONDUIT TO TANK SUMPS SHALL BE ROBROY RIGID STEEL PVC COATED SCHEDULE 40 (NO SUBSTITUTIONS). CONDUIT MINIMUM BURY DEPTH IS 24�° PER CODE. ALL JUNCTION BOXES SHALL 3/4 3" OVER 2" FRP 3-WAY BALL VALVE 60 110 116 � � � Lo CLASS 1 DIV. 2 RATED. ALL ELECTRICAL CONDUIT IN SUMPS SHALL INCLUDE A SEAL-OFF ENTERING AND LEAVING. SEAL-OFFS SHALL BE INSTALLED 6" MIN. ABOVE HIGHEST PENETRATION IN SUMP. — — ADDITIVE PIPING (TYP.) •� Q00 N Lno <br /> 8. - FILL & VAPOR RISER GROUNDING: 3/4" S.S. PIPING AND +J N o <br /> ALL FILL AND VAPOR RISERS SHALL BE GROUNDED TO PREVENT STATIC DISCHARGE. SEE DETAIL E ON SHEET E-4 FOR RISER GROUNDING DETAIL. <br /> FITTINGS - - N Q ) <br /> (A tl- L0 <br /> 2" X 3/4" BELL REDUCER c U-) 4s N c.0 <br /> 9. - STAINLESS STEEL FITTINGS: 3/4" THREADED PLUG m Q - c N o <br /> CONTRACTOR TO PROVIDE ALL MISCELLANEOUS NPT FITTINGS AND NIPPLES FOR CONNECTIONS TO TURBINES, SIPHON SYSTEM 3/4" THREADED PLUG m V Y <br /> AND VAPOR RECOVERY SYSTEM. ALL STAINLESS STEEL FITTINGS SHALL BE MANUFACTURED BY "STANDARD PIPE PRODUCTS" 2" X 3/4" S.S. DOUBLE 3/4" X 15" FLEXIBLE c <br /> OR EQUAL SPECIFICATIONS AS FOLLOWS: TAP BUSHING 53 45 CONNECTOR <br /> DIMENSIONS MATERIAL THREAD PRESSURE RATING 2" NPT TANK BUNG °° °° '° <br /> S.S. FITTINGS 67 NEW 3/4 Y STRAINER 1, <br /> (TEES, ELBOWS) EXISTING TANK TOP TO FITTING <br /> CLASS 150/PN 20 ASME B16.3 ASTM A- 182 ASME B. 1 20. 1 ASME B16.3 REMAIN (TYP.) <br /> 3-WAY BALL VALVE N <br /> 60 3/4 <br /> S.S. UNIONS <br /> U <br /> CLASS 150/PN 20 ASME B16.39 ASTM A- 182 ASME B. 1 20. 1 ASME B16.3 <br /> _ _ _ — E <br /> S.S. PIPE 3 4" S.S. PIPING STINGER TO WITHIN 6" EXISTING 22" MANWAY PLATE Ln <br /> CLASS 150/PN 20 ASTM A733 ASTM A-312 ASME B. 1 20. 1 ASME B16.3 / COVER TO REMAIN CD <br /> TO TANK BOTTOM (FIELD CUT TO LENGTH) Oco <br /> CD <br /> i <br /> 10. - CORROSION PROOF: ('G_')Ga80line Side Sum Section Detail For Additive Automation oALL TURBINE PUMP HEADS TO HAVE ADVANCED CORROSION PROOF PROTECTION WITH E-COATED FINISH. Z O NCD <br /> CD <br /> T5-1 SCALE: 1 " = l '—O" r <br />
The URL can be used to link to this page
Your browser does not support the video tag.