My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:33:30 AM
Creation date
5/31/2022 1:10:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0518288
PE
2351
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARID PERMEATOR INSTALLATION NOTES PERMEATOR INSTALLATION TASKS: <br /> 1 . MECHANICAL: PERMEATOR REQUIRES A 2-INCH LINE FOR EACH FEED AND PERMEATE RETURN LINES, AND A 1 -INCH RETENTATE (EXHAUST). ARID SUPPLIES 2, 6 INCH 1 . MOUNT ELECTRICAL CONTROL CABINET WITHIN CONTROLLER ENCLOSURE. <br /> ANSI 125 , 4-BOLT FLANGES; INSTALL CONTRACTOR PROVIDES THE MATING 6 INCH FLANGES. THE TWO (2) FEED AND PERMEATE LINES ARE PIPED TO THE VERTICAL VENT Z Lo <br /> RISERS USING A "T" AND 90 DEGREE ELBOW AS A "SWING JOINT". ARID ALSO RECOMMENDS THAT LOW RESISTANCE, STRAIGHT-THROUGH BALL VALVES BE INSTALLED 2. ENSURE PRESENCE OF A DEDICATED TELEPHONE LINE JACK WITHIN 6 FEET OF ELECTRICAL CONTROL PANEL. 0 <br /> BETWEEN THE FLANGES AND VENT RISERS ON THE FEED AND PERMEATE RETURN LINES. TYPICALLY, THE RETENTATE (EXHAUST) LINE IS RUN PARALLEL TO THE VENT RISERS Q 0 <br /> AND SUPPORTED WITH UNI-STRUT. IN ADDITION, THE TOP OF THE RETENTATE LINE IS FITTED WITH A RAIN-CAP (NOT A P/V VALVE). 3. BRING MAIN POWER TO CONTROL PANEL AND POWER/CONTROL SIGNAL WIRING FROM CONTROL PANEL TO PERMEATOR J c _ <br /> LOCATED ALONGSIDE VENT PIPES. POWER IS 208 V / 60 HZ / 3 PHASE; 20 AMP SERVICE REQUIRED. CONTROLo J W J <br /> THE FOUR LEGS ON EACH PERMEATOR ARE FORMED WITH HOLES TO ACCOMMODATE RED-HEAD MOUNTING BOLTS TO THE CEMENT PAD LOCATED ADJACENT TO THE VENT WIRING IS 24 VOLT DC (4-20 MA); SIGNAL WIRES SHOULD BE SHIELDED 18 OR 20 AWG CABLE; 1 PAIR, OR 2 ) 0 W jLI V <br /> PIPE RISERS. CONDUCTORS PER EACH SENSOR SIGNAL. PERMEATOR EQUIPPED WITH DATA LOGGER REQUIRES 3 SIGNALS OR 6 z to Z Z L <br /> LI <br /> CONDUCTORS. SEPARATE CONDUITS SHOULD BE USED FOR POWER AND COMMUNICATION CABLES, RESPECTIVELY. o ZO J 0 W <br /> 2. NON-HYDROCARBON SENSOR VERSION--ELECTRICAL: ARID RECOMMENDS USING TWO (2) RIGID CONDUITS. THE FIRST CONDUIT IS FOR RUNNING 3 PAIRS (6 CONDUCTORS) t;TZ H Q Z <br /> OF SHIELDED 18 GAUGE CABLE. THE CONTROL CIRCUIT VOLTAGE IS 24 V DC, AND CURRENT IS 4-20 MILLIAMPS. THE SECOND CONDUIT IS FOR RUNNING POWER WIRES: 208 4. POUR 5 FT. X 5 FT. CEMENT PAD ALONGSIDE VENT PIPES AND MOUNT PERMEATOR WITH 4 BOLTS THROUGH THE � 0 Q Q 0 J <br /> V, 3 PHASE, 60 HZ, 20 AMPS 3 CONDUCTORS (12 OR 14 AWG OR LOCAL CODE) PLUS ONE GROUND WIRE . THESE CONDUITS WILL RUN BETWEEN THE CONTROL PANEL EXISTING SUPPORT STAND LEGS. PERMEATOR MAIN CABINET WEIGHT IS APPROXIMATELY 750 LBS AND FOUR LEGGED o � Q CA > O <br /> LOCATED IN THE CONTROLLER ENCLOSURE HOUSING THE SUBMERSIBLE TURBINE PUMP ELECTRONICS AND A JUNCTION BOX LOCATED ON THE PAD ADJACENT TO OR BASE MEASURES 36 INCHES X 36 INCHES. N N W J C� Q co <br /> MOUNTED ON THE PERMEATOR. THE JUNCTION BOX ON THE PAD WILL COMMUNICATE WITH THE MOTOR OF THE PERMEATOR AND AN ADDITIONAL PERMEATOR MOUNTED I <br /> JUNCTION BOX THROUGH A FLEXIBLE BRANCH CONDUIT OF 3/4 INCH DIAMETER. (TYPICALLY, THESE CONDUITS MAKING FINAL CONNECTIONS BETWEEN RIGID CONDUIT AND 5. CONNECT 2 INCH FEED AND RETURN PIPING TO VENT RISERS; PROVIDE LOW RESISTANCE ("STRAIGHT-THROUGH ") BALL W W O <br /> MOTOR/CONTROL WIRE JUNCTION BOXES ARE WATER-TIGHT FLEXIBLE CONDUITS, RATED FOR HAZARDOUS AREAS) VALVES FOR ISOLATION AND SHUT-OFF ON THE FEED AND PERMEATE RETURN LINES, AND PIPE VAPOR RETURN LINE CD CD C 0- <br /> N V <br /> TO LOW GRADE PRODUCT VENT. PLACE A 2 INCH "T" BETWEEN THE FLANGE CONNECTION AND THE ISOLATION BALL Q _0 co � <br /> THE ELECTRICAL CONTROL PANELS ARE 18" WIDE X 20" LONG X 8" DEEP AND ARE MOUNTED IN THE CONTROLLER ENCLOSURE HOUSING THE PUMP ELECTRONICS. THE VALVE ON THE RICH VAPOR RETURN LINE. ENSURE MINIMUM SLOPE OF 1 /4 TO 1 /8 INCH PER FOOT FROM o 0 o Y <br /> CONTROL PANEL HAS AN INTEGRAL POWER SUPPLY FOR THE CONTROL CIRCUITS, AND ACCEPTS THE 208 V, 3 PHASE, 60 HZ MAIN POWER. (PERMEATOR REQUIRES A 20 PERMEATOR TO VENT RISERS. U Q O 0 <br /> AMP CIRCUIT). m m m m <br /> 6. CONNECT EXHAUST VENT TO PERMEATOR AND SUPPORT BY RUNNING PARALLEL TO EXISTING VENT RISERS, AND CAP _ <br /> INSTALL RATED LOCAL DISCONNECT SWITCH LOCATED NOT WITHIN 18" HORIZONTALLY FROM THE UNIT AND AT LEAST 18" ABOVE GRADE FOR EQUIPMENT MAINTENANCE PURPOSES. INSTALL THE EXHAUST VENT WITH A FRESH AIR VENT CAP. N Qj <br /> ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION. o <br /> coa <br /> PERMEATOR UNIT CIRCUITRY SHALL BE TIED INTO THE EMERGENCY SHUTOFF SWITCH CIRCUITRY SUCH THAT IN THE EVENT OF AN EMERGENCY SHUTDOWN, POWER WILL BE CUT TO THE 7. ARID PERSONNEL TO OVERSEE WIRING TERMINATION CONNECTIONS WITH ELECTRICIAN IN THE FIELD. <br /> z <br /> CONTROL PANEL IN THE CONTROLLER ENCLOSURE AND TO THE MOTORS AT THE PERMEATOR UNIT. <br /> SEE SHEET T6-1 <br /> OIL FILL CAP <br /> FOR PIPING DETAILS 5 <br /> OPW 723V VENT CAP 21 <br /> INSTRUMENT MOUNTING PLATE EMCO WHEATON 180 20 VENT RAIN CAP <br /> 25" X 13" X 1/4" THK. ATMOSPHERIC AIR CAP <br /> O CLEAN AIR VALVE #A4103-002 <br /> MEMBRANE MODULE <br /> 180 OWN <br /> PRESSURE RELIEF VALVE J � <br /> N <br /> 00 N M > OD <br /> RE0040B VACUUM PUMP W/ W — <br /> 3HP TEXP RELIANCE MOTOR J Q Q <br /> 0 0 <br /> M o o C O <br /> Lo = W <br /> � ENCLOSURE W/ LOCKABLE G o CLEAN AIR OUTLET, _ <br /> P 00 DOORS AND VENTS o 1 NPT Q <br /> 0 0 OJQ <br /> u � 0) <br /> c � � <br /> O ca <br /> 36in - V <br /> 4.5in <br /> 41 .875in OVERALL 1" TEE AND 1/4" <br /> TEST PORT <br /> L <br /> 4in Ln � <br /> 3in <br /> O ° o ° O ° 0 Z <br /> w Q <br /> w <br /> 2" TEE AND 1/4" J `� w <br /> / z <br /> 0 5 8 THRU TEST PORT 6' TO 8' z o <br /> SECTION A-A ® ® ABOVE FINISH GRADE D Q <br /> jai SCALE 1 : 4 <br /> FOOT PAD DETAIL <br /> TYPICAL - 4 PLACES o <br /> o BO PIPES SLOPE <br /> l/ PER FOOT DOWN <br /> OIL FILL CAP TO RDS VENT <br /> ° 0 o ss/pH <br /> GROUND 0 <br /> CONNECTION = � <br /> OUTLET (RICH GASOLINE/AIR HAL P. GRUBB � <br /> RETURN TO TANK), 2"- 125# <br /> -� 67814 � <br /> OIL SIGHT GLASS o O ANSI F.F. BY.G.C. <br /> OIL DRAIN 0 ° <br /> Q <br /> INL T LEAN GASOLINE AIR �qTF OF v ��\F���\ <br /> FR M TANK), 2"- 125 CA <br /> C14Qq AN I F.F. BY.G.C. <br /> 05/27/22 <br /> 00 0 0 0 0 0 0 X <br /> 0 <br /> Lo v <br /> U 0 Z j Z m <br /> N <br /> O c <br /> O <br /> 0 0 <br /> ° o .1O N <br /> cn N II <br /> ° O rn 0� C Y <br /> U <br /> N N a ; n <br /> o o 0CL <br /> 0 <br /> o <br /> M O <br /> MLLP DO <br /> N <br /> o • O O <br /> 0o N <br /> O • <br /> uIll 0 � <br /> /��' Y• N <br /> O O W "� m ~ <br /> 34in � ° ° • c0 o <br /> 1 i n �, <br /> 8.95733in <br /> 30.7716535in LJJ C M <br /> DRIP PAN DRAIN QoN o0 o <br /> (PLUGGED) <br /> j 01 N 'n <br /> CD <br /> 3.3307087in — � N <br /> � Q <br /> L <br /> 7 1/8" Lo 4s N <br /> NOTE: ARID TECHNOLOGIES PERMEATOR TO BE m V 00 Y <br /> `o LOCATED IN CONFORMANCE WITH MANUFACTURERS / <br /> CONDENSATE TRAP INSTALLATION MANUAL, CARB EXECUTIVE ORDER / / / / / o <br /> W/ 1 1/4" NPT AND ALL APPLICABLE STATE AND LOCAL CODES. <br /> DRAIN (PLUGGED) NOTE: ADDITIONAL SCREEN WALL OR CONSTRUCTION / <br /> w <br /> MAY BE REQUIRED BY LOCAL ORDINANCES. VERIFY N <br /> REQUIREMENTS WITH ARCHITECT. MINIMUM MOUNTING <br /> REQUIREMENTS ARE SHOWN IN THIS DETAIL. <br /> A A � <br /> U <br /> "PERMEATOR" - RE0040B VACUUM PUMP W/ 3HP TEXP MOTOR, <br /> MEMBRANE MODULE HOUSING, & 36" TALL STAND - DIMENSIONAL o <br /> O <br /> 3in 30in 4X 0 5/8" <br /> � N <br /> THRU Z O <br /> OCDCD <br /> O N <br /> ° T i <br />
The URL can be used to link to this page
Your browser does not support the video tag.