My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 10:31:55 AM
Creation date
6/2/2022 11:21:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231442
PE
2361
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #124
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
217-260-21
CURRENT_STATUS
01
SITE_LOCATION
505 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Secondary Containment Testing Report Form <br /> 6. TANK SECONDARY CONTAINMENT TEST <br /> Test Method Developed by 0 Manufacturer 0✓ Industry Standard © Professional Engineer <br /> Test Type 0 PressureX❑ Vacuum ❑I— Hydrostatic <br /> Test Equipment Used: vacuum Gages <br /> Tank ID Gasoline -87-1 Gasoline -87-2 Gasoline-91 <br /> Tank Manufacturer Xerxes(FRP) Xerxes (FRP) Xerxes (FRP) <br /> Tank Capacity 10,000 10,000 8,000 <br /> Test Start Time 10:15 10:15 10:15 <br /> Initial Reading 10 10 10 <br /> Test End Time 11:15 11:15 11:15 <br /> Final Reading 10 10 10 <br /> Change in Reading 0 0 0 <br /> Pass/Fail Criteria 0 0 0 <br /> Tightness Test Results 0✓ Pass 0 Fail ® Pass © Fail ® Pass 0 Fail ❑ Pass C Fail <br /> 7. PIPE SECONDARY CONTAINMENT TEST <br /> Test Method Developed by El Manufacturer 0 Industry Standard © Professional Engineer <br /> Test Type © Pressure 0 Vacuum © Hydrostatic <br /> Test Equipment Used: Pressure Gages <br /> Pipe Run ID Gasolin-e -87-1 Gasoline -87-2 Gasoline-91 <br /> Pipe Manufacturer Ameron Ameron Ameron <br /> Test Start Time 10:15 10:15 10:15 <br /> Initial Reading 5 5 5 <br /> Test End Time 11:15 11:15 11:15 <br /> Final Reading 5 5 5 <br /> Change in Reading 0 0 0 <br /> Pass/Fail Criteria 0 0 0 <br /> Tightness Test Results M Pass © Fail E Pass r] Fail 0 Pass ID Fail [:1 Pass ® Fail <br /> Pipe Run ID <br /> Pipe Manufacturer <br /> Test Start Time <br /> Initial Reading <br /> Test End Time <br /> Final Reading <br /> Change in Reading <br /> Pass/Fail Criteria <br /> Tightness Test Results 0 Pass 0 Fail ❑ Pass r] Fail 0 Pass 0 Fail C Pass 0 Fail <br /> Additional copies of this page may be attached. <br /> All tests marked "Fail"and any repairs made before or during the tightness test must be described in <br /> the COMMENTS section. <br /> Page 2 of 5 <br />
The URL can be used to link to this page