Laserfiche WebLink
M8.2DETAILSDATE REVISION/ SET05.06.21PERMIT APPLICATIONWMB PROJECT:PUBLISH HISTORY5757 Pacific AvenueSuite 226Stockton, CA 952072000 L StreetSuite 125Sacramento, CA 95811209.944.9110 T209.944.5711 Fwww.wmbarchitects.comDAVID'S PIZZA T.I.4755 Quail Lakes Dr. - Ste. AStockton, CA 9520720-068MECHANICAL- VARIABLE SPEED CONTROL.- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).- HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST- INTERNAL WIRING.- ROOF MOUNTED FANS.- RESTAURANT MODEL.FEATURES:- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).31 7/824 3/4- NEMA 3R SAFETY DISCONNECT SWITCH.- GREASE CLASSIFICATION TESTING.- UL705 AND UL762 AND ULC-S645 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION.3" FLANGE.22 1/222 1/2ROOF OPENINGDIMENSIONS.20 GAUGECONSTRUCTION.STEEL20"23"23"VENTED CURB.EXAMPLE: 7/12 PITCH = 30° SLOPE.PITCHED CURBS ARE AVAILABLEFOR PITCHED ROOFS.SPECIFY PITCH:0"0°12"PROVIDE THE FOLLOWING OPTIONS:GREASE BOX.ECM WIRING PACKAGE - MANUAL OR0-10VDC REFERENCE SPEED CONTROL(TELCO MOTOR), CCW ROTATION.2 YEAR PARTS WARRANTY.22 1/224 3/431 7/814 7/8223DUCTWORK BETWEENEXHAUST RISER ON HOODAND FAN (BY OTHERS).30 1/2GREASE DRAIN.FAN #1 DU85HFA - EXHAUST FANDETAIL:REFER TO EXHAUST FAN MTG. FLEX CONDUITFOR FIELDWIRING.13 1/4"3 7/8"11 1/2"BLOWER DISCHARGE.CURB.1 3/4"3 3/4"LIFTING LUG.AIRFLOW.BLOWER/MOTORACCESS DOOR24" SERVICECLEARANCE REQ.SERVICEDISCONNECTSWITCH.AIRFLOW.18"16"Ø1 1/2"WATERDRAIN.AIRFLOW.Ø1/2" NPTWATER INLETWATER FILTER REQUIREDPROVIDED BY PLUMBER.FILTER/CONTROLACCESS DOOR.LPD CELDEKAIRFLOW.27 3/8"16 1/4"21"20" EQUIPMENT CURB.32 1/8"29 3/4"21"32 1/8"36 3/4"36 3/4"ADJUSTABLELEG.64 1/4"117 7/8"MIN. 14"MINIMUMSTRAIGHTDUCTPER AMCA*FAN #2 A1-G10 - SUPPLY FAN1. UNTEMPERED SUPPLY UNIT WITH 10" BLOWER IN SIZE #1 HOUSING.2. EVAP COOLER (LPD CELDEK) – W/INTAKE HOOD W/EZ FILTERS.3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT.4. 120V WIRING CONNECTION TO ENERGIZE EVAPORATIVE COOLERS FROM UNTEMPERED SUPPLY FANS.6. 2 YEAR PARTS WARRANTY.*NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OFUNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITHTURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THEDUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNITTO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT.SUGGESTED STRAIGHT DUCT SIZE IS 14" x 14".LETSDIRROOF OPENING 2" SMALLER THAN CURB DIMENSION.5"5"16024VHB-G-PSP-FCAPTIVEAIRE8' 0"700DEGIIN/A20016004"4"12"12"80080010191019-0.118"-0.118"1008430 SS100%ALONEALONEHOODNOTAGMODELMANUFACTURERLENGTHMAXCOOKINGTEMPTYPEAPPLIANCEDUTYDESIGNCFM/FTTOTALEXH CFMEXHAUST PLENUMRISER(S)WIDTHLENGHEIGHTDIACFMVELSPTOTALSUPPLYCFMHOODCONSTRUCTIONHOOD CONFIGEND TOENDROW13L55 SERIES E26NONO378LBSHOODNOTAGFILTER(S)TYPEQTYHEIGHTLENGTHEFFICIENCY@ 7MICRONSLIGHT(S)QTYTYPEWIREGUARDUTILITY CABINET(S)LOCATIONSIZEFIRE SYSTEMTYPESIZEELECTRICALMODEL #SWITCHESQUANTITYFIRESYSTEMPIPINGHOODHANGINGWEIGHT1Front96"12"6"MUAMUA10"10"24"24"5045040.140"0.140"HOODNOTAGPOSLENGTHWIDTHHEIGHTTYPERISER(S)WIDTHLENGDIACFMSP11DU85HFACAPTIVEAIRE16000.6501152TEAO-ECM0.7500.277011158.9506 FPM889.8FANUNITNOTAGQTYFAN UNIT MODEL #MANUFACTURERCFMESPRPMMOTORENCLHPBHPPHASEVOLTFLADISCHARGEVELOCITYWEIGHT(LBS)SONES21A1-G10G10A1-14400.500764ODP0.3330.313011155.88.3A15A2.6890.0°F65.0°F70.0°F65.0°F43613.7FANUNITNOTAGQTYFAN UNIT MODEL #BLOWERHOUSINGMINCFMDESIGNCFMESPRPMMOTORENCLHPBHPPHASEVOLTFLAMCAMOCPEVAPFLOW RATE(Gal/Hr)EVAP COOLERENTERING DBTEMPEVAP COOLERENTERING WBTEMPEVAP COOLERLEAVING DBTEMPEVAP COOLERLEAVING WBTEMPWEIGHT(LBS)SONES*Evap Flow Rate is variable based on water pressure.12EF-1MAU-136 LBS39 LBSCURBCURBRAIL23.000"W X 23.000"L X 20.000"H VENTED HINGED.21.000"W X 21.000"L X 20.000"H .4.000"W X 4.000"L X 36.000"H.NOONFANWEIGHTITEMSIZEThese products and others are available for demonstration at the Northern CA display center--For more information or questions Contact--Captive Aire Systems1110 Burnett Ave, Suite G, Concord, CA 94520Phone: (925)962-1999, Fax (925)566-8565 Email reg92@captiveaire.comAll fans must have inverter duty motors, and all conduits from the load side of theVFDs must be seperate and dedicated.KHD-1KHD-1EF-1MAU-1MAU-1