SAN <br /> J O a Q U I N Environmental Health Department <br /> C0U ;N i Y <br /> Food Program Official Inspection Report <br /> Facility Name and Address: TACO HOUSE MEXICAN GRILL, 5066 WEST LN, STOCKTON 95210 <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:The light cover over the storage area was coming off. Repair/replace within 1 week. <br /> Some of the lights in the warewash area were not working. Replace lights within 1 week. <br /> The light in the walk-in cooler was too dim. Provide adequate light inside walk-in. Correct within 1 week. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored, served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #40 Proper Use and Storage of Wiping Cloths <br /> OBSERVATIONS:Observed wiping cloth stored on counter after use. Store wiping cloth in sanitizer bucket with at least 100 <br /> ppm chlorine between uses. Correct immediately. <br /> CALCODE DESCRIPTION:Wiping cloths used to wipe service counters,scales or other surfaces that may come into contact with food <br /> shall be used only once unless kept in clean water with sanitizer. (114135, 114185.1 114185.3(d-e)) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Observed no air gap between 3 comp sink discharge pipe and floor sink. Provide 1 in. minimum air gap <br /> within 1 week. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #44 Premises: Clean/Litter Free;Vermin-Proof <br /> OBSERVATIONS:The back door was being kept open,there was no air curtain or screen. Keep door closed during <br /> operation to keep facility vermin proof. Correct immediately. <br /> CALCODE DESCRIPTION:The premises of each food facility shall be kept clean and free of litter and rubbish all clean and soiled linen <br /> shall be properly stored non-food items shall be stored and displayed separate from food and food-contact surfaces the facility shall be <br /> kept vermin proof. (114067 6), 114123, 114143(a)&(b), 114256, 114256.1, 114256.2, 114256.4, 114257, 114257.1, 114259, 114259.2, <br /> 114259.3, 114279, 114281, 114282) <br /> FA0002789 PRO162652 SCO01 06/22/2022 <br /> EHD 16-23 Rev.09/16/2020 Page 4 of 5 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />