My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003874
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINNE
>
1999
>
2600 - Land Use Program
>
PA-0400090
>
SU0003874
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:37:07 PM
Creation date
7/1/2022 3:55:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0003874
PE
2622
FACILITY_NAME
PA-0400090
STREET_NUMBER
1999
Direction
W
STREET_NAME
LINNE
STREET_TYPE
RD
City
TRACY
APN
23921006,07
ENTERED_DATE
5/11/2004 12:00:00 AM
SITE_LOCATION
1999 W LINNE RD
RECEIVED_DATE
3/10/2004 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
jure 17,2005 <br /> NOA Project Number: E04150A <br /> Page 2 <br /> the four-hour percolation test was observed by Mr. Michael Escotto,Registered Environmental <br /> Health Inspector,EHD. <br /> Measurement of the water level during the percolation test was from a fixed reference point on the <br /> PVC casing using an electric well sounder with an depth accuracy of 1/100th foot. All tabulated <br /> values on the field data sheet(appendix) are in decimal feet. After water drop was observed, the <br /> holes were checked for refill. The refill level was approximately 0.5 ft (6 inches) of water above the <br /> bottom level of the percolation test hole. The readings were taken approximately every 30 minutes <br /> for a four hour test or every 10 minutes for a one hour test. <br /> 6.6 Percolation Test Forms and Results <br /> The completed percolation test forms are included in the appendix of this report. <br /> A shallow percolation test is defined by the EHD as being between 36 and 42 inches in depth;a <br /> satisfactory percolation rate for a shallow test is less than or equal to 60 minutes per inch drop. <br /> Details of the percolation tests are summarized in Table 9. <br /> Table 9. <br /> Sionm of Percolation Tests. <br /> Test No., Percolation Percolation Rate 'Test Comment <br /> Date Tested Test Depth(ft) (minutes/inch) Duration (scc notes) <br /> P-1 shallow,2-23-05 3.10 1.70 1-hr Satisfactory percolation rate <br /> (Parcel 1) <br /> P-2 shallow,2-15-05 323 20.8 4-hr, Sads£actory percolation rate <br /> (Parcel 2) <br /> P-3 shallow,2-17-05 3.24 4.46 4-hr. Satisfactory percolation roc <br /> (Parcel 3) <br /> P-4 Shallow,3-8-05 3.5 7.81 4-hi. Satisfactory percolation rate <br /> (Parcel 4) <br /> P-5 shallow,2-2405 3.05 5.81 4-hr. Satisfactory percolation rate <br /> arcel 5 <br /> Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> 6.6:Attached to this letter is the corrected percolation test form for Parcel 2. <br /> 0/Z0 30Vd OHIlAN3 NOSd3QNd -1I3N 8ZZb69C60Z 59:L0 900Z/ZZ/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.