My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOUNTAIN HOUSE
>
19533
>
2300 - Underground Storage Tank Program
>
PR0547762
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 11:24:15 AM
Creation date
7/6/2022 9:54:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0547762
PE
2351
FACILITY_ID
FA0027204
FACILITY_NAME
SAFEWAY FUEL CENTER #0055
STREET_NUMBER
19533
Direction
S
STREET_NAME
MOUNTAIN HOUSE
STREET_TYPE
PKWY
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
01
SITE_LOCATION
19533 S MOUNTAIN HOUSE PKWY
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N J O A Q U I N Environmental Health Department <br /> COUNTY <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored. <br /> lK 25290.1 c 1 <br /> 25290.2 c 1 <br /> 23 CCR <br /> X 2631(b) Design and construction of piping approved by independent testing organization(e.g. UL). <br /> X Piping, including vent lines,sloped toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> HSC <br /> 25290.1 k Vapor recovery, fill riser, and vent line piping are secondarily contained. <br /> X 25290.2�c;&0) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check Code <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> X 2635(b) Manufacturer OPW Model P761 C <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> X 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> X Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model 71 SO-41 OCT <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> X Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> X 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> X FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> X 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(a)(2) <br /> current <br /> X Tie-downs,when used, constructed of non-corrosive material or coated steel. <br /> 7 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.