My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
6465
>
3600 - Recreational Health Program
>
PR0360578
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2022 1:47:57 PM
Creation date
7/6/2022 1:46:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360578
PE
3611
FACILITY_ID
FA0007459
FACILITY_NAME
WESTPOINTE APARTMENTS SE POOL
STREET_NUMBER
6465
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09405030
CURRENT_STATUS
01
SITE_LOCATION
6465 N WEST LN
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br />10:30 am <br /> 9:45 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 951-4391 Owner/Operator: PATMON COMPANY INC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 6465 N WEST LN, STOCKTON 95210 <br />Date: 06/27/2022Name of Facility: WESTPOINTE APARTMENTS SE POOL <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #1 Pool Gates MAJOR <br />OBSERVATIONS: The north gate was not self-latching. Keep gate locked and provide self-latching gate prior to re-opening. <br />CALCODE DESCRIPTION: Gates and doors leading into the pool area shall be equipped with self-closing self-latching devices. <br />Self-latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool area <br />except where otherwise prohibited by law. (CBC 3119B) Pool operator shall keep gates and doors leading into the pool area well <br />maintained. (CCR 65535) <br /> #4 Safety Equipment <br />OBSERVATIONS: The life ring did not have rope. Attach rope to life ring immediately. Corrected on site. <br />The life ring was cracking. Replace life ring prior to re-opening. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #7 Pool Deck <br />OBSERVATIONS: Observed raised tree root along middle of pool deck near hand rail and raised concrete pads near <br />skimmers creating tripping hazards. Repair/resurface pool deck so that it is free of tripping hazards prior to re-opening pool. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The ladder hand rails were loose. Secure hand rails today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0007459 PR0360578 SC001 06/27/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.