My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
6465
>
3600 - Recreational Health Program
>
PR0360578
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2022 1:47:57 PM
Creation date
7/6/2022 1:46:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360578
PE
3611
FACILITY_ID
FA0007459
FACILITY_NAME
WESTPOINTE APARTMENTS SE POOL
STREET_NUMBER
6465
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09405030
CURRENT_STATUS
01
SITE_LOCATION
6465 N WEST LN
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: WESTPOINTE APARTMENTS SE POOL, 6465 N WEST LN, STOCKTON 95210 <br />Swimming Pool Official Inspection Report <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Observed chipping in pool shell. Replaster pool shell prior to opening next season. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Skimmer was missing weir door. Provide within 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The gallons per minute markings on the flow meter were not legible. Provide flow meter with legible GPM <br />markers. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 90 <br />7.4 <br />4.0 <br /><30 Combined chlorine:ppm <br />NOTES <br />Influent: 10 PSI <br />Keep pool closed until pool deck is repaired/resurfaced and gate door is self-latching. <br />Call EHD for re-inspection to verify corrections prior to re-opening pool. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 616-3035 <br />, <br />DARIA AFONSKAIA <br />Page 2 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0007459 PR0360578 SC001 06/27/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.