Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DA Archer Excavating 1819 S ARGONAUT ST, STOCKTON July 12, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 302 CCR 66262.34(d)(2) Failed to have all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: The facility is not equipped with the following equipment: spill control equipment. <br /> REGULATION GUIDANCE: <br /> All facilities shall be equipped with the following, unless it can be demonstrated to the Department that none of the <br /> hazards posed by waste handled at the facility could require a particular kind of equipment specified below: <br /> (a)an internal communications or alarm system capable of providing immediate emergency instruction (voice or <br /> signal)to facility personnel; <br /> (b)a device, such as a telephone (immediately available at the scene of operations)or a hand-held two-way radio, <br /> capable of summoning emergency assistance from local police departments,fire departments, or State or local <br /> emergency response teams; <br /> (c)portable fire extinguishers,fire control equipment(including special extinguishing equipment, such as that using <br /> foam, inert gas, or dry chemicals), spill control equipment, and decontamination equipment; and <br /> (d)water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or <br /> automatic sprinklers, or water spray systems . <br /> CORRECTIVE ACTION: Immediately install the following equipment: spill control equipment. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department within <br /> 30 days. <br /> This is a Class II violation. <br /> 505 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks. <br /> OBSERVATION: The hazardous waste tank storing used oil does not have complete labeling.The tank had no <br /> accumulation start date. <br /> REGULATION GUIDANCE: All hazardous waste tanks shall be marked with the words"Hazardous Waste"and the <br /> accumulation start date. <br /> CORRECTIVE ACTION: Label the hazardous waste tanks with the words"Hazardous Waste"and the accumulation <br /> start date. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a minor violation. <br /> FA0003767 PR0513694 SCO01 07/12/2022 <br /> EHD 22-01 Rev.9/16/2020 Page 5 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />