ModBus RTU Interface Card Specifications <br /> ModBus RTU Interface Cards Provide Simple, Efficient Connectivity Between <br /> TMS/LC2000 Systems and Building Management Systems or PLCs <br /> Bic <br /> Single-Channel MODULE <br /> 900943. 1 REV <br /> d y S. 1 Hi <br /> ;+ <br /> N <br /> J <br /> I <br /> Dual-Channel Quad-Channel <br /> Product Description <br /> The ModBus RTU Interface Cards are plug-in connectivity products that offer an easy, cost-effective solution providing access to all TMS <br /> real-time tank management data from practically any building management system or programmable logic controller supporting the industry- <br /> standard ModBus RTU serial communications protocol. Available TMS/LC2000 data includes continuous tank data, statuses and alarms, <br /> leak/point level sensor statuses and contact closure input statuses. Communications is over a half duplex, single twisted-pair RS485 cable <br /> up to 4000 feet in length, with a switch-selectable line termination resistor for multi-drop configurations . Installation and setup is quick and <br /> easy, requiring no programming on the TMS/LC2000 console. Available in single, dual and quad-channel configurations, isolated or non- <br /> isolated. <br /> Features <br /> • Industry-standard interface to most building management systems and programmable logic controllers <br /> • Add ModBus RTU support to any TMS/LC2000 System, either as a factory-shipped option or as a field upgrade* <br /> • Installs within the locked TMS/LC2000 enclosure for secure, tamperproof connectivity <br /> • No TMS/LC2000 programming required. Simply set slave address and baud rate on ModBus RTU card dip switches. <br /> • ModBus status register allows host processor to confirm continuous updating of ModBus registers by TMS/LC2000 <br /> • Single, dual and quad-channel(TMS3000/4000 only) configurations available, with isolated or non-isolated options. <br /> Specifications <br /> • Communications Protocol : Modbus RTU • LED Indicators: TX (Slave Transmit), RX (Global <br /> • Communications Format: RS485, Half-Duplex Receive) <br /> • Connection Type : Plug-In Terminal Block with Wire 0 Serial Data Format: Fixed, I Start Bit, N-8- I <br /> Entries 0 Baud Rate : 9600 or 38400, Dip Switch Selectable <br /> Input: Ch. A (+), Ch. B (-), Shield Slave Address Select: 1 thru 64, Dip Switch Selectable <br /> Output: Ch. A (+), Ch. B (-), Shield Maximum Slave Response Time: 400 ms <br /> • Maximum Number of 16-Bit Registers per READ <br /> • Recommended RS-485 Cable: Belden 9841 (PVC Jacket), Command : 64 <br /> 89841 (FEP Teflon Jacket) or similar 0 Maximum Register Update Rate from TMS : 1 .2 seconds <br /> • Maximum Cable Length: 4000 Feet ( 1200 Meters) total to (0. 8 seconds typ.) <br /> end of run <br /> Model Numbers <br /> • 90055240 Single Non-Isolated Input 0 900665-R-R Dual Isolated Inputs <br /> • 901050- 10 Single Isolated Input • 90093144 Quad Isolated Inputs, TMS3000 <br /> • 900665-5-5 Dual Non-Isolated Inputs . 900931 -34 Quad Isolated Inputs, TMS4000 <br /> *Requires TMS firmware Vxx.99.94 or later, available at no charge with purchase of ModBus card. <br /> Note: Specifications subject to change without notice. 06-16-2021 <br /> ����� PNEUMERCATOR Pneumercator Company , Inc. Tel : 631 -293-8450 <br /> Llquld Leve/ Control Systems 1785 Expressway Drive North Fax: 631493-8533 <br /> Hauppauge, New York 11788 httn://www. nneumercator.com <br />