My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2023 2:40:08 PM
Creation date
7/21/2022 10:35:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I Level g <br /> Rigid Magnetostrictive Probe, EPA Compliant* <br /> i <br /> Product Description <br /> The MP450S Level Gauging Probe utilizes proven Magnetostrictive technology for accuracy and reliability. When used in conjunction <br /> with the TMS2000/3000, it provides the ability to perform EPA compliant in-tank leak tests in underground storage tanks. The probe is <br /> available in lengths up to eighteen feet. <br /> Applications <br /> • Above and Below Ground Storage Tanks 0 Oil / Water Separators (See MP452S Series spec) <br /> • Bulk Storage Tanks • All Petroleum Products <br /> • Generator Sub Base Tanks • Most Chemical Solvents <br /> Specifications <br /> • Technology: Magnetostrictive, Dual Float, w/ reflection resolution doubling <br /> • Accuracy (Minimum) : Product Level : 0.0005 " (0 .013 mm) <br /> Water Level : 0. 001 " (0.025 mm) <br /> Temperature : 0.001 OF (0.0006 °C) <br /> • Materials : Shaft: 316 SS <br /> Floats : Buna-N (Optional 316 SS or Urethane) <br /> • Riser Mount: Minimum 2" (51 mm) dia . riser, 4" ( 102 mm) dia. riser required for in-tank leak <br /> • Direct Mount: Minimum 2" (51 mm) opening with bushing or flange mount <br /> • Probe Lengths : 1 ' — 18 ' (305 mm — 5486 mm) <br /> • Temperature Sensing: 6 Thermistors; 5 in shaft, 1 in probe head <br /> • Location Approval : UL Class I, Div 1 , Groups C and D ; cUL Class I, Zone 0, Group IIB <br /> • Operating Temperature: 40 OF to 175 OF (40 nC to 80 °C) <br /> • Operating Pressure: 150 PSIG ( 1034 kPa) <br /> • Field Wiring: 22AWG, 2-Conductor twisted pair w/ shield <br /> Belden 8441 , 8761 , Alpha 1736C or equiv. , maximum length 3000 ' to 4600 ' (914 in to 1402 m) <br /> Installation <br /> Probes 15 ' (4.6 m) or less in length can be installed into a vertical riser pipe with the probe foot contacting the tank bottom, or <br /> direct-mounted at the tank top via a V NPT compression fitting kit. Probes greater than 15 ' (4 .6 m) must be direct-mounted. <br /> Certifications/Approvals <br /> • UL/cUL Approved*, File #E 139464 <br /> • Third-Party Approved, EPA-Compliant for In-Tank Leak Testing: * <br /> Up to 20,000 Gal . (75 ,708 Liter) tank capacity, minimum tank inventory for test 20% <br /> 0 .2 GPH (0. 8 LPH) Leak Test: Pd = 99.9%, Pfa = 0. 1 % <br /> 0 .2 GPH (0. 8 LPH) Quick Test: Pd = 95%, Pfa = 5% <br /> 0 . 1 GPH (0.4 LPH) Precision Test: Pd = 95 .3%, Pfa = 4.7% <br /> Up to 75,000 Gal . (283 ,906 Liter) tank capacity, minimum tank inventory for test 50% <br /> 0 . 2 GPH (0.8 LPH) Leak Test: Pd = 97 .3 %, Pfa = 2.7% <br /> * When used in conjunction with the TMS2000/3000 series controllers <br /> Note: specifications subject to chmgewithout notice. 04-01-2013 <br /> /L//Uyffli ERCATOR PneumercatorCompany, Inc. Tel : 631 -293-8450 <br /> vel Control SysteMS 1785 Expressway Drive North Fax: 631 -293-8533 <br /> Hauppauge, New York 11788 http://www.Dneumercator. com <br />
The URL can be used to link to this page
Your browser does not support the video tag.