My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2023 2:40:08 PM
Creation date
7/21/2022 10:35:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment 2 <br /> Summary Of Performance Estimates <br /> Pipeline Release Detection Method <br /> Hourly Test <br /> First Test Of A Multiple-Test Sequence <br /> Complete this page only if the method being evaluated requires , as part of its test procedures , more than <br /> one complete test to determine whether the pipeline is leaking. Method performance based on the first <br /> test alone must be reported on this form . Complete the first table . The last three tables present the <br /> performance of the method for different combinations of thresholds , probabilities of false alarm , and <br /> probabilities of detection . They are useful for comparing the performance of this method to that of other <br /> methods . However, completion of the last three tables is optional . <br /> Performance Of The Pipeline Release Detection Method As Evaluated <br /> Description Leak Rate P(d) P(fa) Threshold <br /> (gal r) al/hr <br /> Evaluated Method 3 . 0 100% 0% L8 <br /> EPA Standard 3 . 0 0 . 95 0 .05 N/A <br /> P(fa) As A Function Of Threshold <br /> Threshold P(fa) <br /> al/hr <br /> 0 . 10 <br /> 0 . 075 <br /> 0 . 05 <br /> 0 . 05 <br /> P(d) As A Function Of Threshold For A Leak Rate Of 3 . 0 gal/hr <br /> Threshold P(d) <br /> al/hr <br /> 0 .95 <br /> 0 . 90 <br /> 0 . 80 <br /> 0 . 50 <br /> Smallest Leak Rate That Can Be Detected With The Specified P(d) and P(fa) <br /> Leak Rate P(d) P(fa) <br /> al/hr <br /> 0 .95 0 . 10 <br /> 0 .95 0 .075 <br /> 0 .95 0 .05 <br /> 0 .90 0 .05 <br /> 0 . 80 0 .05 <br /> 0 . 50 0 .05 <br /> Pipeline Release Detection System Page 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.