My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2023 2:40:08 PM
Creation date
7/21/2022 10:35:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_chart by <br /> _computer <br /> X by microprocessor <br /> 23 . Certain calculations are necessary to reduce and analyze the data. How are these calculations done? <br /> _ manual calculations by the evaluator on site <br /> _interactive computer program used by the <br /> _automatically done with computer program <br /> X automatically done with a microprocessor <br /> Detection Criterion <br /> 24 . What threshold is used to determine whether the pipeline is leaking? <br /> The threshold for any charge pressure, volume and bulk modulus can vary based on the time of pressure <br /> decay from pressure to 10 psi . For this evaluation, the threshold to declare an alarm was less than 12 <br /> minutes and 40 seconds . (in the units used by the measurement system) <br /> (in gal/hr) <br /> 25 . Is a multiple-test sequence used to determine whether the pipeline is leaking? <br /> _yes (If yes, answer the three questions below)no (If no, skip the 3 <br /> questions below) <br /> X no <br /> How many tests are conducted ? <br /> How many tests are required before a leak can be declared? <br /> What is the time between tests ? <br /> (Enter 0 if the tests are conducted one after the other. ) <br /> Calibration <br /> 26 . How frequently are the sensor systems calibrated? <br /> X never <br /> _before each test <br /> _weekly monthly <br /> _semi-annually <br /> _yearly or less frequently <br /> Pipeline Release Detection System Page 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.