S A N J O a Q U I N Environmental Health Department <br /> — C 0 j :V y <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: SHADOW LAKE MOBILE HOME PARK LLC, 5100 N HWY 99 , STOCKTON 95212 <br /> #15 Operation Records <br /> OBSERVATIONS:Observed pool operation records for June, lacking records for July and August. Maintain daily logs of <br /> chlorine and pH when pool is operating. <br /> CALCODE DESCRIPTION:Pool operator shall test the disinfectant residual,pH, and spa water temperature a minimum of once per day. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Northwest skimmer float assembly was damaged. Replace float assembly within 1 week. <br /> Both west skimmers were lacking o-rings. Provide o-rings within 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #35 Flow Meters <br /> OBSERVATIONS:Flow meter was not working. Provide working flow meter today. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 3125B) <br /> #39 Wastewater Disposal <br /> OBSERVATIONS:Currently backwash is disposed of into storm drain. Dispose of backwash into sewer system. Correct <br /> today. <br /> CALCODE DESCRIPTION:Backwash from sand filters shall discharge indirectly into a sump with sufficient capacity to receive <br /> wastewater without overflowing. Backwash from diatomaceous earth filters shall discharge into a separation tank designed to collect the <br /> diatomaceous earth mixture. Wastewater from the separation tank shall discharge into the sanitary sewer.A visible sight indicator shall <br /> be installed on the backwash line when discharge is not visible to the pool operator.Pool recirculation system shall not be directly <br /> connected to the sanitary sewer system. (CBC 3141B)Cartridge filters shall be cleaned in an approved wash down area equipped with <br /> potable water supply. Wash down area shall discharge through permanently installed plumbing into the sanitary sewer. (CBC 31328) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 4.2 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: >8 Combined chlorine: ppm <br /> NOTES <br /> Routine inspection. <br /> Influent: 22 PSI <br /> Effluent: 15 PSI <br /> Keep pool closed until pH correction is verified by EHD. <br /> FA0002794 PR0360127 SCO01 08/03/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />